HomeMy WebLinkAboutORDINANCE 6246113 West Mountain Street Fayetteville, AR 72701 (479) 575-8323 Ordinance: 6246 File Number: 2019-0624 JACK TYLER ENGINEERING, INC.: AN ORDINANCE TO WAIVE COMPETITIVE BIDDING AND ACCEPT A QUOTE IN THE AMOUNT OF $22,120.39 PLUS APPLICABLE TAXES AND FREIGHT CHARGES FROM JACK TYLER ENGINEERING, INC. FOR THE REBUILD OF A PUMP AND MOTOR FOR THE HAMESTRING SEWER LIFT STATION, AND TO APPROVE A BUDGET ADJUSTMENT WHEREAS, Pump No. 2 at the Hamestring Sewer Lift Station was recently taken out of service and shipped to Jack Tyler Engineering to disassemble, inspect, and provide a quote for a rebuild of the pump; and WHEREAS, pursuant to Ark. Code Ann. §19-11-203(14)(DD), formal competitive bidding is not necessary for the repair of "hidden or unknown damages." NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE, ARKANSAS: Section 1: That the City Council of the City of Fayetteville, Arkansas hereby determines that because of Ark. Code Ann. § 19-11-203(14)(DD), repair of "hidden or unknown damages," the rebuild of the pump does not require formal competitive bidding and, therefore, waives competitive bidding and accepts the quote in the amount of $22,120.39 (plus any applicable taxes and freight charges) from Jack Tyler Engineering, Inc. for the rebuild of a pump and motor for the Hamestring Sewer Lift Station. Page 1 Printed on 10116119 File Number.' 2019-0624 Ordinance 6246 Section 2: That the City Council of the City of Fayetteville, Arkansas hereby approves a budget adjustment, a copy of which is attached to this Ordinance. PASSED and APPROVED on 10/15/2019 Attest: Lisa Branson, Deputy `arkrR��i,�� ����� • 0T Y 0� 01 1-. �• FA •� _ TTEVILLE��' :v •.9 5 : � '�J.S,'. kANsp'.•��� �i / • .... • ' J �� TON Page 2 Pd,nted on 1011619 . n City of Fayetteville, Arkansas 113 West Mountain Street Fayetteville, AR 72701 (479) 575-8323 1 Text File File Number: 2019-0624 Agenda Date: 10/15/2019 Version: 1 Status: Passed In Control: City Council Meeting File Type: Ordinance Agenda Number: C. 6 JACK TYLER ENGINEERING, INC.: AN ORDINANCE TO WAIVE COMPETITIVE BIDDING AND ACCEPT A QUOTE IN THE AMOUNT OF $22,120.39 PLUS APPLICABLE TAXES AND FREIGHT CHARGES FROM JACK TYLER ENGINEERING, INC. FOR THE REBUILD OF A PUMP AND MOTOR FOR THE HAMESTRING SEWER LIFT STATION, AND TO APPROVE A BUDGET ADJUSTMENT WHEREAS, Pump No. 2 at the Hamestring Sewer Lift Station was recently taken out of service and shipped to Jack Tyler Engineering to disassemble, inspect, and provide a quote for a rebuild of the pump; and WHEREAS, pursuant to Ark. Code Ann. §19-11-203(14)(DD), formal competitive bidding is not necessary for the repair of "hidden or unknown damages." NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE, ARKANSAS: Section 1: That the City Council of the City of Fayetteville, Arkansas hereby determines that because of Ark. Code Ann. § 19-11-203(14)(DD), repair of "hidden or unknown damages," the rebuild of the pump does not require formal competitive bidding and, therefore, waives competitive bidding and accepts the quote in the amount of $22,120.39 (plus any applicable taxes and freight charges) from Jack Tyler Engineering, Inc. for the rebuild of a pump and motor for the Hamestring Sewer Lift Station. Section 2: That the City Council of the City of Fayetteville, Arkansas hereby approves a budget adjustment, a copy of which is attached to this Ordinance. City of Fayetteville, Arkansas Paye 1 Printed on 1011612019 City of Fayetteville Staff Review Form 2019-0624 Legistar File ID 10/15/2019 City Council Meeting Date - Agenda Item Only N/A for Non -Agenda Item Tim Nyander 9/16/2019 WASTEWATER TREATMENT (730) Submitted By Submitted Date Division / Department Action Recommendation: Staff recommends the approval of a repair quote from Jack Tyler Engineering, Inc. in the amount of $22,120.39 plus applicable taxes and freight for a pump and motor rebuild for the Hamestring wastewater lift station, and approval of a budget adjustment. Original Contract Number: Comments: Freight is estimated at $1,000.00 and taxes are estimated at $2,254.24 for an estimated total of $25,374.63. Budget Impact: 5400.730.5800-5414.00 Water and Sewer Account Number Fund 02069.1 Plant Pumps and Equipment - WWTP Project Number Project Title Budgeted Item? Yes Current Budget $ 1,157,303.00 Funds Obligated $ 1,157,298.32 Current Balance $ 4.68 Does item have a cost? Yes Item Cost $ 25,374.63 Budget Adjustment Attached? Yes Budget Adjustment $ 25,375.00 Remaining Budget $ 5.05 V20180321 Purchase Order Number: Previous Ordinance or Resolution # Change Order Number: Approval Date: Original Contract Number: Comments: Freight is estimated at $1,000.00 and taxes are estimated at $2,254.24 for an estimated total of $25,374.63. CITY OF FAYETTEVILLE ARKANSAS MEETING OF OCTOBER 15, 2019 TO: Mayor and City Council THRU: Don Marr, Chief of Staff Water & Sewer Committee FROM: Tim Nyander, Utilities Director DATE: September 16, 2019 CITY COUNCIL MEMO SUBJECT: Pump and Motor Rebuild for Hamestring Wastewater Lift Station RECOMMENDATION: Staff recommends the approval of a repair quote from Jack Tyler Engineering, Inc. in the amount of $22,120.39 plus applicable taxes and freight for a pump and motor rebuild for the Hamestring wastewater lift station, and approval of a budget adjustment. BACKGROUND: The Hamestring sewer lift station on Sunshine Road delivers over 85% of the West Side treatment facility's average 7+ MGD of wastewater influent. The station, first brought online in June 2008, utilizes a series of seven 350 hp Cornell -brand pumps that have been in operation for just over 11 years. Pump No. 2 has been scheduled for maintenance rebuild as a 2019 CIP project following 48,000 hours or nearly 5.5 years of run-time service. Performing maintenance rebuilds on a preventive schedule, for instance approximately every 45,000 operating hours, safeguards against potentially more costly pump failures or unexpected pump unavailability at a location critical to the West Side facility's operation. DISCUSSION: Recently, Pump No. 2 was taken out of service and shipped to Jack Tyler Engineering, in Little Rock, for disassembly inspection and a rebuild cost proposal. Jack Tyler Engineering submitted a quote to rebuild the pump and motor in the amount of $22,120.39. Staff recommends completion of the proposed rebuild of the lift station pump and motor in the amount of $22,120.39 plus applicable taxes and freight. Freight is estimated at $1,000.00 and taxes are estimated at $2,254.24 for an estimated total of $25,374.63. Because it was necessary to have the repair facility disassemble the units to determine the extent of hidden and unknown damage to equipment already purchased, a bid waiver and/or formal sealed bidding is not necessary according to Ark. Code Ann. §19-11-203(14)(DD). Mailing Address: 113 W. Mountain Street www.fayetteville-ar.gov Fayetteville, AR 72701 BUDGET/STAFF IMPACT: Funds will be moved from the Sanitary Sewer Rehabilitation account to the Plant Pumps and Equipment account to cover the costs of the pump and motor rebuild. Funds being moved are budgeted funds for sewer rehabilitation/replacement and maintenance. Attachments: Quote from Jack Tyler Engineering, Inc. Budget Adjustment PUMP INSPECTION REPORT A�or �^ai Jack Tyler Engineering, Incorporated 4 6112 Patterson Road Little Rock, AR 72209-2430 (501) 562-2296 Phone (501) 562-4273 Fax CUSTOMER: CH2M Hill REGARDING THE 12NHG28-F20 WITH S/N# 145781 Hamestdng LS (LS#7) 2053 N. Sunshine Rd. Fayetteville, AR 72704 The customer has reported vibration within the pump housing, need to check all possible reasons: bearings, seals, shaft and impeller balance. Inboard Bearing Condition: Outboard Bearing Condition: Mechanical Seal Condition: Shaft Condition: Impeller Condition: Rough - replace Rough - replace Worn - replace Need to be balanced Worn - replace Dynamic Wear Ring Condition: Worn - replace (new impeller includes installed wear ring) Stationary Wear Ring Condition: Not in Shop, need to inspect volute for wear When our pump technician inspected the pump, he discovered the shaft felt rough when hand -turned. This would mean that when the pump is turning at motor speed, the bearings would have caused the whole pump housing to vibrate. In order to eliminate any further cause of vibration, we need to have the shaft with the bearings and impeller assembled in order to balance the assembly. Impeller lead time -- 11 weeks. Page: 1 Quote Jack Tyler Engineering, Incorporated 6112 Patterson Road A Little Rock, AR 72209-2430 (501) 562-2296 Phone i'coor�� (501) 562-4273 Fax Sold To: CH2M Hip Operations Management (OMI) P.O. Box 241329 Denver, CO 80224-1329 Conflrm To: Ship To: Hamestring LS (LS #7) 2053 N Sunshine Rd Fayetteville, AR 72704 Order Number: 0130125 Order Date: 9/13/2019 Quoted By: CBOHNER Entered by: chrlsb Salesperson: 5016 Customer Number: 0010802 Customer Fax: (720) 286-9184 Customer P.O. Ship VIA Freight F.O.B. Terms JTE DELIVERY Net 15 Item Number Unit Ordered Shipped Back Order Price Amount CORNELL PUMP MODEL 12NHG28-F20 WITH SM# 145781 Balance shah and Impeller as complete assembly CUSTOMER HAS PROVIDED ORING, SHAFT SLEEVE, MECH SEAL, BEARINGS, SHIMS, IMPELLER BOLT /LABOR HR 12.00 AND WASHER 0.00 0.00 Service Labor /REPAIR EACH 1.00 0.00 0.00 18,140.39 18,140.39 Repair Misc Shop Supplies D5884-3PB-CI-L EACH 1.00 0.00 1.00 0.00 0.00 IMPELLER - CORNELL Whse: 001 NORMAL LEAD TIME FOR REPAIR 12-14 WE S, ARO 'A659AI-197GA EACH 1.00 0.00 0.00 0.00 0.00 VOLUTE GASKET Net Order. 18,140.39 /BOV MACHINING 1.00 0.00 0.00 0.00 0.00 BOV Machine Work Balance shah and Impeller as complete assembly /LABOR HR 12.00 0.00 0.00 0.00 0.00 Service Labor /SHOP SUPPLIES 1.00 0.00 0.00 0.00 0.00 Misc Shop Supplies /FREIGHT EA 1.00 0.00 0.D0 0.00 0.00 Freight, Shipping & Handling NORMAL LEAD TIME FOR REPAIR 12-14 WE S, ARO Net Order. 18,140.39 Sales Tax and Freight Charges are NOT included in quoted price Freight not to exceed $500.00 Thank you for the opportunity to quote on your requirements. If you have any questions, please do not hesitate to contact us. NOTE: This quotation expires 30 days from above date unless noted. Quote �'%et E^ Jack Tyler Engineering, Incorporated g ! 6112 Patterson Road o Little Rock, AR 72209-2430 � (501) 562-2296 Phone (501) 562-4273 Fax Sold To: CH2M Hitt Operations Management (OMI) P.O. Box 241329 Denver, CO 80224.1329 Confirm To: JEREMY LACOE Ship To: Hamestring LS (LS N7) 2053 N Sunshine Rd Fayetteville, AR 72704 Page: Order Number. 0130321 Order Date: 91312019 Quoted By: OGB Entered by: OGB Salesperson: S016 Customer Number. 0010802 Customer Fax: (720) 286-9184 Customer P.Q. Ship VIA Freight F.O.B. Terms JTE DELIVERY Net 15 Item Number Unit Ordered Shipped Back Order Price Amount /BOV EQT REPAIR EACH 1.00 0.00 0.00 3,980.00 3,980.00 BOV Equipment Repair 6322 BEARING 6222 BEARING CLEAN, BAKE AND INSULATE STATOR SHOP LABOR INSULATE SPRAY ANALYZER REPORT MEG AND HI POT TEST 9m�9 STT J��J--s N / oyz �'grt�3 P Net Order 3,98000 Sales Tax NOT included in quoted price Thank you for the opportunity to quote on your requirements. if you have any questions, please do not hesitate to contact us. NOTE: This quotation expires 30 days from above date unless noted. Z JACK TYLER ENGINEERING, INCORPORATED 6112 PATI-ERSON AVENUE, LITTLE ROCK, ARKANSAS 72209 i 0a (501) 562-2296 - FAX (501) 5624273 - ARKANSAS WATS 1-800-562-2296 rP cc�� STATEMENT OF TERMS AND CONDITIONS TERMS/PAYMENTS: Our terms of payment are net cash 15 days from date of the Invoice subject to Seller's prior credit approval. If the Buyer shall fail to make any payments in accordance with the terms and conditions of sate, the Seiler, in addition to its other rights and remedies, but not In limitation thereof, may, at its option, without prior notice, cancel this order as to any undelivered products or defer shipments or deliveries hereunder, or under any other agreement between Buyer and Seller, except upon Seller's receipt of cash before shipment or such security as Seller considers satisfactory. In the event Buyer's failure to make timely payments to Seller results in Seller incurring additional costs, including but not limited to collection expenses and attorneys' fees, said costs shall be added to the amount due Seller from Buyer. Buyer shall have no right to any discount or retainage and shall not withhold payment as a set-off on Seller's Invoice in any amount Visa, MasterCard, Discover, and American Express credit card purchases are accepted. SHIPMENT: The date of shipment is subject to our receiving your order with complete information at our office, final approval of any prints or drawings as may be required, credit approval, and the acceptance of your order by the company. Freight Charges are not Included in the quoted price. EXPIRATION: Quotation expires 30 days from the date of proposal and, In the Interim, is subject to change without notice. TAXES: Unless otherwise stated In the proposal, the prices quoted herein are exclusive of all sales, use and similar taxes and, wherever applicable, such taxes will be added to the Invoice as separate items. RETURNS/REFUNDS: Items wished to be returned are subject to prior approval and must be accompanied by a Retum Merchandise Authorization (RMA). Items returned without proper approval and/or paperwork will be returned to the customer at their expense. Returns past 30 days of initial receipt will not be accepted. All returned items are subject to a restocking fee. The customer's credit will be equal to the credit Jack Tyler Engineering, Inc. receives from the vendor, minus orginal freight and freight back to the vendor. Please note that all items must be returned to JTEI, who will return the item to the vendor. Credit will only be issued once JTEI receives credit from the vendor. THIS PROPOSAL IS BASED ON CURRENT PRICES. EQUIPMENT IS SUBJECT TO THE SAME PERCENTAGE INCREASE AS MADE BY OUR SUPPLIERS AND THE INVOICE WILL REFLECT PRICE IN EFFECT AT TIME OF SHIPMENT UNLESS SPECIFICALLY EXCEPTED. WE WILL NOT ACCEPT RETAINAGE ON ANY OF OUR INVOICESI ----' A $50.00 minimum order charge will apply ----- `The products sold by Jack Tyler Engineering, Inc. hereunder are manufactured by others, and the only warranties that apply to these products are those of the manufacturer of the products which can be passed on by Jack Tyler Engineering, Inc. to its customers. No other warranty of any kind Is given In connection with the sale of any of the above products, and JACK TYLER ENGINEERING, INC. MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR AS TO ANY OTHER MATTER RESPECTING THESE PRODUCTS. Jack Tyler Engineering, Inc. shall not be liable in connection with the sale of the above products for any Incidental or consequential damages of any kind' An electronic copy of the latest version Is available online at www.jteng.com. Form No. 41-1 Rev. 07 - 07/12/19 City of Fayetteville, Arkansas - Budget Adjustment Form (Legistar) Budget Year Division Adjustment Number /Org2 WASTEWATER TREATMENT (730) 2019 Requestor: Cheryl Partain BUDGET ADJUSTMENT DESCRIPTION / JUSTIFICATION: A Budget Adjustment is needed in the Plant Pumps and Equipment - WWTP project for a pump and motor rebuild for the Hamesting Wastewater Lift Station. Budgeted funds from the Sanitary Sewer Rehabilitation project will be transferred to this project to cover the cost of this item. The budgeted funds being transferred are for sewer rehabilitation/replacement and maintenance. RESOLUTION/ORDINANCE TOTAL COUNCIL DATE: 10/15/2019 LEGISTAR FILE ID#: 2019-0624 L ink H atche+w 911712019 4:34 PM Budget Director TYPE: JOURNAL #: GLDATE: CHKD/POSTED: Date D - (City Council) v.20190516 Increase / (Decrease) Proiect.Sub# Account Number Expense Revenue Project Sub.Detl AT Account Name 5400.730.5800-5414.00 25,375 - 02069 1 EX Plant Equipment Maintenance 5400.720.5700-5815.00 (25,375) - 02017 1 EX Sewer Improvements H:\Budget Adjustments\2019_Budget\City Council\10-15-2019\2019-0624 BA Jack Tyler Engineering Inc 1 of 1 RECEIVED NOV 0 5 2019 RKANSACERNORTHWESTA�fLKS C Vem0c t vette AFFIDAVIT OF PUBLICATION I Cathy Staggs, do solemnly swear that I am the Accounting Manager for the Northwest Arkansas Democrat -Gazette, printed and published in Washington County and Benton County, Arkansas, and of bona fide circulation, that from my own personal knowledge and reference to the files of said publication, the advertisement of: CITY OF FAYETTEVILLE Ord. 6246 Was inserted in the Regular Edition on: October 20, 2019 Publication Charges: 118.56 G04.x��� Cathy Sg s Subscribed and sworn to before me This ? ( day of CW1 2019. &;V, tt4 Notary Public My Commission xpires: CATHY WILES Arkansas - Benton County Notary Public - Comm# 12397118 My Commission Expires Feb 20, 2024 **NOTE** Please do not pay from Affidavit Invoice will be sent. Ordinance: 6246 File Number: 2019-0624 JACK TYLER ENGINEERING, INC.: AN ORDINANCE TO WAIVE COMPETITIVE BIDDING AND ACCEPT A QUOTE IN THE AMOUNT OF 522,120.39 PLUS APPLICABLE TAXES AND FREIGHT CHARGES FROM JACK TYLER ENGINEERING, INC. FOR THE REBUILD OF A PUMP AND MOTOR FOR THE HAMESTRING SEWER LIFT STATION, AND TO APPROVE A BUDGET ADJUSTMENT WHEREAS, Pump No. 2 at the Hamestring Sewer Lift Station was recently taken out of service and shipped to Jack Tyler Engineering to disassemble, inspect, and provide a quote for a rebuild of the pump, and WHEREAS, pursuant to Ark. Code Ann. § 19- 11-203(14)(DD), formal competitive bidding is not necessary for the repair of "hidden or unknown damages." NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE, ARKANSAS: Section 1: That the City Council of the City of Fayetteville, Arkansas hereby determines that because of Ark. Code Ann. § 19-11- 203(14xDD), repair of "hidden or unknown damages," the rebuild of the pump does not require formal competitive bidding and, therefore, waives competitive bidding and accepts the quote in the amount of 522,120.39 (plus any applicable taxes and freight charges) from Jack Tyler Engineering, Inc. for the rebuild of a pump and motor for the Hamestring Sewer Lift Station. Section 2: That the City Council of the City of Fayetteville, Arkansas hereby approves a budget adjustment, a copy of which is attached to this Ordinance. PASSED and APPROVED on 10/15/2019 Approved: Lioneld Jordan, Mayor Attest: Lisa Branson, Deputy City Clerk 75125480 10/20/2019