Loading...
HomeMy WebLinkAbout175-19 RESOLUTION113 West Mountain Street Fayetteville, AR 72701 (479)575-8323 Resolution: 175-19 File Number: 2019-0436 JACK TYLER ENGINEERING, INC.: A RESOLUTION TO AUTHORIZE THE PURCHASE OF A PUMP FOR THE SOLIDS HANDLING ODOR CONTROL SYSTEM AT THE PAUL R. NOLAND WASTEWATER TREATMENT FACILITY FROM JACK TYLER ENGINEERING, INC. IN THE AMOUNT OF $10,900.00 PLUS APPLICABLE TAXES AND FREIGHT CHARGES, AND TO APPROVE A BUDGET ADJUSTMENT BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE, ARKANSAS: Section 1: That the City Council of the City of Fayetteville, Arkansas hereby accepts a quote in the amount of $10,900.00 plus applicable taxes and freight chargers from Jack Tyler Engineering, Inc. for the purchase of a centrifugal sump pump for the solids handling odor control system at the Paul R. Noland Wastewater Treatment Facility. Section 2: That the City Council of the City of Fayetteville, Arkansas hereby approves a budget adjustment, a copy of which is attached to this Resolution. PASSED and APPROVED on 8/6/2019 Page 1 Attest: Sondra E. Smith, City Clerk Trea� CLERk�T C/T •;A y •��G'j.•�VSAS ••.' `�� ; 01 i NO ; `,��. �01111) f pAYF T$,,,,:, City of Fayetteville, Arkansas 113 West Mountain Street / \ Fayetteville,AR 72701 v (479)575-8323 : .:,,if Text File �~°"SPS File Number: 2019-0436 Agenda Date:8/6/2019 Version: 1 Status:Agenda Ready In Control: City Council Meeting File Type: Resolution Agenda Number:A. 3 JACK TYLER ENGINEERING,INC.: A RESOLUTION TO AUTHORIZE THE PURCHASE OF A PUMP FOR THE SOLIDS HANDLING ODOR CONTROL SYSTEM AT THE PAUL R. NOLAND WASTEWATER TREATMENT FACILITY FROM JACK TYLER ENGINEERING, INC. IN THE AMOUNT OF $10,900.00 PLUS APPLICABLE TAXES AND FREIGHT CHARGES,AND TO APPROVE A BUDGET ADJUSTMENT BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE,ARKANSAS: Section 1: That the City Council of the City of Fayetteville, Arkansas hereby accepts a quote in the amount of $10,900.00 plus applicable taxes and freight chargers from Jack Tyler Engineering, Inc. for the purchase of a centrifugal sump pump for the solids handling odor control system at the Paul R. Noland Wastewater Treatment Facility. Section 2: That the City Council of the City of Fayetteville, Arkansas hereby approves a budget adjustment, a copy of which is attached to this Resolution. City of Fayetteville,Arkansas Page 1 Printed on 8/7/2019 City of Fayetteville Staff Review Form 2019-0436 Legistar File ID 8/6/2019 City Council Meeting Date-Agenda Item Only N/A for Non-Agenda Item Tim Nyander 7/11/2019 WASTEWATER TREATMENT(730) Submitted By Submitted Date Division/ Department Action Recommendation: Staff recommends the replacement of a centrifugal pump for the Solids Handling Odor Control system at the Paul R. Noland Wastewater Treatment Facility from Jack Tyler Engineering, Inc. in the amount of$10,900.00 plus applicable freight and taxes, and approval of a budget adjustment. Budget Impact: 5400.730.5800-5801.00 Water and Sewer Account Number Fund 02069.1 Plant Pumps and Equipment-WWTP Project Number Project Title Budgeted Item? Yes Current Budget $ 1,081,246.00 Funds Obligated $ 1,081,243.25 Current Balance $ 2.75 Does item have a cost? Yes Item Cost $ 12,621.25 Budget Adjustment Attached? Yes Budget Adjustment $ 12,622.00 Remaining Budget $ 3.50 V20180321 Purchase Order Number: Previous Ordinance or Resolution# Change Order Number: Approval Date: Original Contract Number: Comments: Freight is estimated at$600.00 and taxes are estimated at$1,121.25 for a total of$12,621.25. CITY OF opp: - FAYETTEVILLE CITY COUNCIL MEMO ar ARKANSAS MEETING OF AUGUST 6, 2019 TO: Mayor and City Council THRU: Don Marr, Chief of Staff Water & Sewer Committee Tim Nyander, Utilities Director FROM: Greg Weeks, Wastewater Treatment DATE: July 11, 2019 SUBJECT: Centrifugal Pump Replacement for Noland Wastewater Treatment Facility RECOMMENDATION: Staff recommends the replacement of a vertical-mount centrifugal pump for the Solids Handling Odor Control system at the Paul R. Noland Wastewater Treatment Facility from Jack Tyler Engineering, Inc. in the amount of$10,900.00 plus applicable freight and taxes, and approval of a budget adjustment. BACKGROUND: The Noland Treatment Facility utilizes two odor control systems, one at the facilities Influent Headworks building (OSC-1) and the second at the Solids Handling building (OSC-2) where WAS or wasted biosolids are belt-press dewatered and loaded into the semi-trucks for transport to the Biosolids Management Site. The odor control systems operate as three-stage chemical scrubbers where dilute solutions of caustic (NaOH) and bleach (NaOCI) remove odorous gases, primarily hydrogen sulfide (H2S), from the building's exchange air. Large air-intake units generate several interior air-exchanges per hour where the building's exhaust air passes through the odor control units. Replacement of the failed chemical recirculation pump will ensure the functionality of odor removal from Noland's biosolids-handling process as needed. DISCUSSION: Recent inspection of a failed Stage 2/3 recirculation pump found the degree of wear-damage to internal components extensive enough that complete replacement of all components is necessary. Vanton quotes comparing cost of an overhaul rebuild kit (parts only) to the cost of a new pump show a percent difference of only 20%. Especially when accounting for the additional labor costs associated with rebuilding the old pump, and the value of a standard warranty acquired with a new pump purchase, staff believes that a new pump purchase is the best • choice. Jack Tyler Engineering out of Little Rock, AR recently submitted a low bid of$10,900.00 for a new Vanton-brand Stage 2/3, vertical-mount centrifugal pump for the facility's Solids Handling Building OSC-2 system. Jack Tyler Engineering is the only regionally authorized supplier for Vanton-brand equipment. Vanton Pump & Equipment Corp. out of Hillside, New Jersey submitted the next highest price quote, while R.C. Beach &Associates, Inc. submitted a Mailing Address: 113 W. Mountain Street www.fayetteville-ar.gov Fayetteville, AR 72701 no bid response as they are located outside the Arkansas sales region for Vanton products. Freight is estimated at $600.00 and taxes are estimated at $1,121.25 for a total of $12,621.25. BUDGET/STAFF IMPACT: Budgeted funds will be moved from the Sanitary Sewer Rehabilitation account to the Plant Pumps and Equipment account to cover the replacement costs for the centrifugal pump at the Noland WWTP. Funds being moved are budgeted funds for sewer rehabilitation/replacement and maintenance. Attachments: Three Quotes Budget Adjustment 2 ��,et En9i7 U �^ (p 7 a e °°rpota� Jacobs Jeremy LaCoe 7/11/2019 Subject: Vanton Pump Mr. LaCoe, JACK TYLER ENGINEERING, INC. 6112 Patterson Road Little Rock, AR 72209 Office: (501) 562-2296 FAX: (501) 562-4273 Email: scott@jteng.com Thank you for allowing me to quote you the Vanton pump. We greatly appreciate the opportunity to earn your business. Included on the next pages are our detailed quote. Please let me know if you have any questions or need any additional information. Sincerely, Scott Jones Senior Sales Representative Jack Tyler Engineering, Inc 6112 Patterson Rd Little Rock, AR 72209 Cell: 479-806-8970 Off: 501-562-2296 C1,\ev Engin U � r JACK TYLER ENGINEERING, INCORPORATED 6112 Patterson Avenue, Little Rock, Arkansas 72209 >'_ PoraiQa 501-562-2296 Fax - 501-562-4273 * Toll Free - 800-562-2296 QUOTATION QUOTATION NUMBER: 62019GWB QUOTATION DATE: 7/11/2019 PAGE: 1 OF 2 INQUIRY DATE: YOUR INQUIRY NO.: TO: Jacobs ATTN: Jeremy LaCoe COPIES: Greg W. Cory G. Stephen E. PHONE: FAX: Email: Ix) Vanton Sump -Gard® vertical centrifugal sump pump Model SGA-PY4x3x10-SP, with all fluid contact parts of homogeneous non-metallic materials, dynamically balanced, keyed, closed impeller, stainless steel shaft completely sleeved with polypropylene. Material of Construction ........Polypropylene Impeller Dia .........................9.25" Discharge ...........................3" Flanged "X" Dimension ...................... 24" "Y" Dimension ...................... 21" Coverplate ...........................24" x 30" x 11/4" Strainer Basket .....................Included Wet Shaft Bearings...............Vanite outer vs. ceramic inner Wet Bearing Lubrication ........ Product Flush Coupling Guard ....................Included *MOTOR AND COUPLING NOT INCLUDED* Price For Above.............................................................................................................$10,900.00 EA. FOB: Factory - NO FREIGHT ALLOWED ESTIMATED FREIGHT: $600.00 Delivery: 4-5 Weeks, ARO Thank you for the opportunity to quote on your requirements. If you have any questions, please do not hesitate to contact us at 501-562-2296. Very truly yours, JACK TYLER ENGINEERING, INC. Scott Jones I Senior Sales Representative WE ARE SERIOUS ABOUT SERVICE! Net Ei7 �fi ,sem JACK TYLER ENGINEERING, INCORPORATED 6112 Patterson Avenue, Little Rock, Arkansas 72209 or of �� 501-562-2296 , Fax - 501-562-4273 - Toll Free - 800-562-2296 QUOTATION QUOTATION NUMBER: 62019GVVB QUOTATION DATE: 7/11/2019 PAGE: 2 OF 2 INQUIRY DATE: YOUR INQUIRY NO.: TO: Jacobs Should thi�;offer be acceptable, please sign below and fax to: 501-562-4273 - Date: - L )-0 Sig Purchase Vrder Number: �o k>° ,,-%wtd � N1-ckas1h\� WE ARE SERIOUS ABOUT SERVICE! TERMS/PAYMENTS: Our terms of payment are net cash 15 days from date of the invoice subject to Seller's prior credit approval. If the Buyer shall fail to make any payments in accordance with the terms and conditions of sale, the Seller, in addition to its other rights and remedies, but not in limitation thereof, may, at its option, without prior notice, cancel this order as to any undelivered products or defer shipments or deliveries hereunder, or under any other agreement between Buyer and Seller, except upon Seller's receipt of cash before shipment or such security as Seller considers satisfactory. Seller reserves the right to impose an interest charge of 16% on the balance of each invoice not paid on its due date for the period from the due date to the date of receipt of payment by Seller. In the event Buyer's failure to make timely payments to Seller results in Seller incurring additional costs, including but not limited to collection expenses and attorneys' fees, said costs shall be added to the amount due Seller from Buyer. Buyer shall have no right to any discount or retainage and shall not withhold payment as a set-off on Seller's invoice in any amount. Visa, MasterCard, Discover, and American Express credit card purchases are accepted. SHIPMENT: The date of shipment is subject to our receiving your order with complete information at our office, final approval of any prints or drawings as may be required, credit approval, and the acceptance of your order by the company. Freight Charges are not included in the quoted price. EXPIRATION: Quotation expires 30 days from the date of proposal and, in the interim, is subject to change without notice. TAXES: Unless otherwise stated in the proposal, the prices quoted herein are exclusive of all sales, use and similar taxes and, wherever applicable, such taxes will be added to the invoice as separate items. SPECIAL NOTE: THIS PROPOSAL IS BASED ON CURRENT PRICES. EQUIPMENT IS SUBJECT TO THE SAME PERCENTAGE INCREASE AS MADE BY OUR SUPPLIERS AND THE INVOICE WILL REFLECT PRICE IN EFFECT AT TIME OF SHIPMENT UNLESS SPECIFICALLY EXCEPTED. WE WILL NOT ACCEPT RETAINAGE ON ANY OF OUR INVOICES! ***** A $50.00 minimum order charge will apply ***** WARRANTY: "The products sold by Jack Tyler Engineering, Inc. hereunder are manufactured by others, and the only warranties that apply to these products are those of the manufacturer of the products which can be passed on by Jack Tyler Engineering, Inc. to its customers. No other warranty of any kind is given in connection with the sale of any of the above products, and JACK TYLER ENGINEERING, INC. MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR AS TO ANY OTHER MATTER RESPECTING THESE PRODUCTS. Jack Tyler Engineering, Inc. shall not be liable in connection with the sale of the above products for any incidental or consequential damages of any kind." An electronic copy of the latest version is available online at www.jteng.com. Form No. 41-1 Rev. 07 - 06/27/17 ANION January 9, 2019 Quote No. S -21120 -TR Jacobs Fayetteville, AR Attention: Troy Ashby Tel No.: 479-443-3292 Subject: Request for Quotation; Pump ODC-RP-202 Dear Troy: Per your request, we are pleased to quote our Sump -Gard@ Model SGA-PY4x3x10-SP, based on an existing unit, Serial No. S-28105 built in 2011. This unit is rated for 600 GPM against a 40 ft TDH. THE PUMP Vanton Sump -Gard@ vertical centrifugal sump pump Model SGA-PY4x3x10-SP, with all fluid contact parts of homogeneous non-metallic materials, dynamically balanced, keyed, closed impeller, stainless steel shaft completely sleeved with polypropylene. Material of Construction Impeller Dia. Discharge "X" Dimension "Y" Dimension Coverplate Strainer Basket Polypropylene Special SG -2400; 9.25" 3" Flanged 24" 21" 24" x 30" x 1'/4" Included Lubrication Product Flush Wet Bearings Vanite outer vs. ceramic inner Coupling Guard Included Unit Price (Pump -end only) ................$ 11,250.00 Ea. Motor & coupling not included VANTON PUMP & EQUIPMENT CORP. 201 Sweetland Avenue Hillside, N J 07205-1793 Tel: 908-688-4216 Fax: 908-686-9314 http://www.vanton.com e-mail: mkt@vanton.com Jacobs Pg 2 January 9, 2019 Quote S -21120 -TR Notes and/or Exceptions ■ Our quotation is limited to items specified. ■ Vanton will not be responsible for piping, accessories, field wiring and/or installation. We hope this offer meets with your approval. If you have any questions or require further assistance, please do not hesitate to contact us at your convenience. Regards, VANTON PUMP & EQUIPMENT CORP. Thomas Riveley F. O. B.: Hillside, NJ, freight not included; Terms: 1 % 10 Days, Net 30 (subject to credit approval), Visa, MasterCard & American Express cards accepted. Shipment: 2 to 3 weeks ARO. Vanton does have expedited service available to meet more urgent requirements. Please contact the factory for additional information regarding rush deliveries. C:\Users\Tom\Documents\quotes\Quotes 2019\S-21120-Jacobs.doc From: amps@rcbeach.com To: Hickle, Jeff/FAY Subject: RE: [EXTERNAL] RE: Vanton Pump Quote Request Date: Thursday, June 13, 2019 10:23:47 AM Yes, that is correct. Thank You, Wendy AMPS(&rcbeach.com R.C. Beach & Assoc., Inc. 539 San Christopher Drive Dunedin Florida 34698 Office 727-736-3696 Fax 727-733-2647 From: Hickle, Jeff/FAY <Jeff. H ickle@jacobs.com> Sent: Thursday, June 13, 2019 10:58 AM To: amps@rcbeach.com Cc: 'Ken Comerford' <kcomerford@vanton.com> Subject: RE: [EXTERNAL] RE: Vanton Pump Quote Request Good morning Wendy, Thanks for the reply back on the Vanton pump inquiry. Is my understanding correct that Arkansas falls outside of RC Beach & Associates supply region for Vanton products? Best Regards Jeff Hickle Environmental Projects Specialist D 479 443 3292 M 479 445 5676 CH2M is now Jacobs. 1400 N Fox Hunter Road Fayetteville, AR 72701 www.gacobs.com I Linkedln I Twitter I Facebook I Instagram From: amps(cDrcbeach.com <amps(@rcbeach.com> Sent: Thursday, June 13, 2019 9:54 AM To: Hickle, Jeff/FAY <Jeff.Hickle(@jacobs.com> Cc: 'Ken Comerford' <kcomerford(@vanton.com> Subject: [EXTERNAL] RE: Vanton Pump Quote Request Jeff, I did receive this previously and sent it to Vanton. We are the manufactures rep for Florida. I will copy this to Vanton again and follow up that they receive it. Thank You, Wendy AMPS(a)rcbeach.com R.C. Beach & Assoc., Inc. 539 San Christopher Drive Dunedin Florida 34698 Office 727-736-3696 Fax 727-733-2647 From: Hickle, Jeff/FAY <Jeff.Hicl<le(@iacobs.com> Sent: Thursday, June 13, 2019 10:41 AM To: infoPrcbeach.com Subject: RE: Vanton Pump Quote Request Good morning, I wanted to follow up on this earlier request on pricing for a Vanton Sump -Gard pump. Thank you Jeff From: Hickle, Jeff/FAY Sent: Friday, June 07, 2019 4:34 PM To: info(cDrcbeach.com Subject: Vanton Pump Quote Request Good afternoon, My name is Jeff Hickle and I work with Jacobs Engineering out of Fayetteville, AR. I am interested in pricing and availability of a Vanton-model vertical centrifugal pump described below. Vanton Sump -Gard® vertical centrifugal sump pump Model SGA-PY4x3x10-SP, with all fluid contact parts of homogeneous non-metallic materials, dynamically balanced, keyed, closed impeller, stainless steel shaft completely sleeved with polypropylene. Material of Construction Polypropylene Impeller Dia. Special SG -2400; 9.25' Discharge 3" Flanged "X" Dimension 24" "Y" Dimension 21" Coverplate 24" x 30" x 1'/4" Strainer Basket Included Lubrication Product Flush Wet Bearings Vanite outer vs. ceramic inner Coupling Guard Included Assuming this model of pump is available through R.C. Beach & Associates, thank you for a quote for this style unit. Best Regards Jeff Hickle Environmental Projects Specialist D 479 443 3292 M 479 445 5676 CH21M is now Jacobs. 1400 N Fox Hunter Road Fayetteville, AR 72701 www.'acobs.com I LinkedInI Twitter I Facebook I Instagram NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer. NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer. City of Fayetteville, Arkansas - Budget Adjustment Form (Legistar) Budget Year Division WASTEWATER TREATMENT (730) Adjustment Number 2019 /Org2 Requestor: Cheryl Partain BUDGET ADJUSTMENT DESCRIPTION / JUSTIFICATION: A Budget Adjustment is needed in the Plant Pumps and Equipment - WWTP project for the replacement of the centrifugal pump at Noland WWTP. Budgeted funds from the Sanitary Sewer Rehabilitation project will be transferred to this project to cover the cost of this item. The budgeted funds being transferred are for sewer rehabilitation/replacement and maintenance. RESOLUTION/ORDINANCE COUNCIL DATE: 8/6/2019 LEGISTAR FILE ID#: 2019-0436 HaV y 3lac� 7/12/2019 11:16 AM Budget Director Date TYPE: JOURNAL #: GLDATE: CHKD/POSTED: TOTAL - - x.20190516 Increase / (Decrease) Proiect.Sub# Account Number Expense Revenue Project Sub.Detl AT Account Name 5400.730.5800-5801.00 12,622 02069 1 EX Fixed Assets 5400.720.5700-5815.00 (12,622) 02017 1 EX Sewer Improvements H:\Budget Adjustments\2019_Budget\City Council\08-06-2019\2019-0436 BA Jack Tyler Eng - pump WWTP 1 of 1