HomeMy WebLinkAbout193-18 RESOLUTION113 West Mountain Street
Fayetteville, AR 72701
(479) 575-8323
Resolution: 193-18
File Number: 2018-0448
PUREGREEN EQUIPMENT SERVICES, LLC:
A RESOLUTION TO AUTHORIZE A CONTRACT WITH PUREGREEN EQUIPMENT SERVICES,
LLC D/B/A EZ FUEL-BLUEIUSA FOR THE PURCHASE OF FUELING EQUIPMENT IN THE
AMOUNT OF $135,997.31 PURSUANT TO THE SOURCEWELL COOPERATIVE PURCHASING
CONTRACT FOR THE FUEL STATION IMPROVEMENT PROJECT, AND TO APPROVE A PROJECT
CONTINGENCY IN THE AMOUNT OF $20,000.00
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE,
ARKANSAS:
Section 1: That the City Council of the City of Fayetteville, Arkansas hereby authorizes Mayor Jordan
to sign a contract with PureGreen Equipment Services, LLC d/b/a EZ Fuel-B1uelUSA for the
purchase of fueling equipment in the amount of $135,997.31 pursuant to the Sourcewell cooperative
purchasing contract for the fuel station improvement project, and further approves a project contingency in
the amount of $20,000.00.
PASSED and APPROVED on 9/18/2018
Attest:
'i La - 'gtazet , x
Sondra E. Smith, City Clerk
Page 1 Printed on 9124118
City of Fayetteville, Arkansas 113 West Mountain Street
Fayetteville, AR 72701
(479) 575-8323
Text File
File Number: 2018-0448
Agenda Date: 9/18/2018 Version: 1 Status: Passed
In Control: City Council Meeting File Type: Resolution
Agenda Number: A. 4
PUREGREEN EQUIPMENT SERVICES, LLC:
A RESOLUTION TO AUTHORIZE A CONTRACT WITH PUREGREEN EQUIPMENT SERVICES,
LLC D/B/A EZ FUEL-BLUElUSA FOR THE PURCHASE OF FUELING EQUIPMENT IN THE
AMOUNT OF $135,997.31 PURSUANT TO THE SOURCEWELL COOPERATIVE PURCHASING
CONTRACT FOR THE FUEL STATION IMPROVEMENT PROJECT, AND TO APPROVE A
PROJECT CONTINGENCY IN THE AMOUNT OF $20,000.00
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE, ARKANSAS:
Section 1: That the City Council of the City of Fayetteville, Arkansas hereby authorizes Mayor Jordan to sign a
contract with PureGreen Equipment Services, LLC d/b/a EZ Fuel-BluelUSA for the purchase of fueling
equipment in the amount of $135,997.31 pursuant to the Sourcewell cooperative purchasing contract for the
fuel station improvement project, and further approves a project contingency in the amount of $20,000.00.
City of Fayetteville, Arkansas Page 1 Printed on 9121/2018
Jesse Beeks/Sara Glenn
Submitted By
City of Fayetteville Staff Review Form
2018-0448
Legistar File ID
9/18/2018
City Council Meeting Date - Agenda Item Only
N/A for Non -Agenda Item
8/15/2018 FLEET OPERATIONS (770)
Submitted Date Division / Department
Action Recommendation:
A resolution to authorize an agreement with EZ Fuel, of Buford, GA, pursuant to the Sourcewell Contract, for the
fuel station improvement project in the amount of $135,997.31 with a 10% project contingency.
Budget Impact:
9700.770.1920-5801.00 Shop Improvements
Account Number
12007.1
Project Number
Budgeted Item? Yes
Does item have a cost? Yes
Budget Adjustment Attached? No
Fund
Shop Improvements
Current Budget
Funds Obligated
Current Balance
Item Cost
Budget Adjustment
Project Title
$ 159,320.00
$ 159,320.00
$ 135,997.31
Remaining Budget [ $ 23,322.69
V20180321
Purchase Order Number: Previous Ordinance or Resolution #
Change Order Number:
Original Contract Number:
Comments:
Approval Date:
CITY OF
FAYETTEVILLE
ny
ARKANSAS
MEETING OF SEPTEMBER 18, 2018
TO: Mayor and City Council
THRU: Terry Gulley, Director of Transportation
FROM: Jesse Beeks, Fleet Operations Superintendent
DATE: August 15, 2018
SUBJECT: Fuel Station Improvement Project
CITY COUNCIL MEMO
RECOMMENDATION:
A resolution to authorize an agreement with EZ Fuel, of Buford, GA, pursuant to the Sourcewell
Contract, for the fuel station improvement project in the amount of $135,997.31 with a 10%
project contingency.
BACKGROUND:
Currently at the Fleet shop there is a 6,000 gallon unleaded fuel tank purchased in 2007. At the
time of the purchase the city had many vehicles that required diesel fuel. For that reason, we
have ample diesel fuel storage. The City has been moving to more unleaded fueled vehicles
and need larger storage capacity.
With new emission regulations more diesel vehicles are required to have Diesel Exhaust Fluid
(DEF) each year. Currently Fleet has a small hatch in the side of the shop with a hose for the
DEF fluid. This is cumbersome for the drivers who must fuel at the station and then drive
around the building to get DEF fluid. This is also cumbersome for Fleet staff as the vehicles
waiting to get fluid block work bays.
When the fuel station was set up at Fleet, the two fuel dispensers were purchased used. They
are now having mechanical issues frequently, causing disruptions in service to the user
departments.
DISCUSSION:
Fleet recommends exchanging the current 6,000 gallon above ground tank for a 10,000 gallon
tank.
Fleet recommends the purchase of a Tote Cabinet that can be placed at the fueling station to
house the DEF fluid. This will make fueling an easier process for operators, give Fleet staff
more open areas and allow Fleet to meter the DEF fluid for better reporting.
Fleet recommends replacing the two dispensers at the Fleet site and one dispenser at Police
Department's site with a digital system that will work with up to date software.
Mailing Address:
113 W. Mountain Street www.fayetteville-ar.gov
Fayetteville, AR 72701
EZ Fuel can provide all the above-mentioned items pursuant to the Sourcewell Contract in the
amount of $135,997.31 with a $20,000.00 contingency.
BUDGET/STAFF IMPACT:
Sufficient funds have been budgeted for these purchases.
Attachments:
Sourcewell Contract Price Sheet
CX FUEL .l I
i&%%,w.EZFua1.cum
August 23, 2018
Mrs. Sara Glenn
City of Fayetteville
1525 S. Happy Hollow Road
Fayetteville, AR 72701
t bj AAWARDEQ
t GNTRACI
#040215 -PGE
EZ Fuel/BluelUSA NJPA Contract #040215- PG E
We take pride in engineering our systems with the highest quality components that are designed for the demanding commercial fueling market. Our products and
services are all available through Sourcewell (formally NJPA) contract #040215 -PGE
Site: 1525 S. Happy Hollow Road
9EZ-10,000FS 10,000 Ga110rn UL 142 Fiameshield System -Gasoline:
• One double-wall UL142 aboveground storage tank 96"Dia x 27'L
• Heavy-duty polyurethane primer and high -gloss white finish
• Installed compartments 24" manway, W emergency vent (Morrison Brothers 244M),8" Interstitial vent (MB 244M), gas working vent (MB 794)
• Installed Red Jacket 3/4HP submersible pump (410140-022), Mechanical line leak detector (116-058-5), Isotrol Control box (880-047-1) 2" ball valve (MB
691), Solenoid valve (MB710-220V), emergency valve (MB 346)
• Automatic overfill shutoff valve (MB 9095)
• Morrison clock gauge (MB 818), Interstitial leak gauge (Krueger At -A -Glance)
• Two (2) steel lifting lugs, rebar style observation ladder
• One spare opening each (2", 4")
Notes: Reuse existing Fuelmaster fuel management, fill boxjeuse Veeder Root probe, reuse existing power and communications wiring, see attached install matrix
N Wayne Dispensers:
• Two twin hose one product 3/G7242D/2GJK/K/H 22gpm ELECTRONIC remote dispenser, internal filter, dual pulse output
• Installed two (2) Goodyear 3/a" x 10' hose,'/" OPW automatic nozzle, %" Catlow breakaway and swivel gasoline
• Installed two (2) Goodyear 1" x 10' hose; 1" OPW automatic nozzle; 1" Catlow breakaway and swivel diesel
Notes: Reuse existing Fuelmaster fuel management, power and communications wiring, all work above shear valve, see attached install matrix
NTC -DI ST131uelUSA Single Tote Cabinet with Integrated Dispenser:
• 48"W x 96"L x 89"H with integrated fork lift slots
• Pre -wired electrical components meet UL -508A and CSA C22.2 standards
• Conforms to 150 22241-3,4 standards
• NEMA 2 rated electrical panel
• NEMA 4 110VAC 30amp disconnect with earth ground required
• Weatherproof, insulated housing, doors and roof
• Lockable double doors
• Fork list compatible composite frame
• Card reader 100:1 pulse output
• 110VAC continuous duty rated DEF pump
• Leak -proof fittings & BSPP connections
• Thermostatically controlled heater
• OPT-DISP SS dispenser with gallons/totalizer LCD display
• OPW Elaflex nozzle with miss fill prevention, OPW swivel breakaway, 20' spring rewind reel
• 5' Suction hose and Micro -Matic coupler
• 1Micron product filter
Notes: Tote and DEF chemical not included. City of Fayetteville supplies tote and fluid, see attached install matrix
Notes: Reuse existing Fuelmaster fuel management, power and communications wiring, see attached install matrix
[1]
- - pTI�A WARDED_
aaRt.at_ EZ Fu � 1. c a to
11040215 -PGE
Site: Church Street "up town"
Mayne Dispensers:
• One single hose one product suction pump 3JG7201P/2H1/JW/H//122gpm ELECTRONIC dispenser, Internal filter, pulse output, hose mast
• Installed one (1) Goodyear %" x 10' hose, %* DPW automatic nozzle, l." Catlow breakaway and swivel gasoline
Notes: Reuse existing Fuelmaster fuel management, power and communications wiring, all work above shear valve, see attached Install matrix
Pricing Brenkdow :
Quantity
Part#
Description
Price Each
Extended Price
I
EZ10,000FS
10,000 Gallon, UL -142, Flamesbicld tank
S 37,948.00
S 37,99$.00
2
EZ-Wayac
Electronic Titin hose single product dispensers
S 6,985.00
S 13,970.00
1
Totc-Disp
Tote cabinet whit integrated dispenser
S 11,149.00
S 11,109.00
I
EZ -HRS
Labor and materials to complete scope of work listed on matrix dated
8-9.2018
S 51,312.00
S 51,312.00
1
EZ Wayne
Electronic Single hose single product suction pump
S 5,128.00
S 5,128.00
I
EZ AILS
Labor and metciials to complete scope ofwork listed on matrix dated
8-9-2018
S 2,650.00
S 2,650.00
I
SUBTOTAL
Subtotal equipment and labor
S 121,876.00
1
SALES TA7t:
Washington County 9.75°! Sales tax
S t t,882,91
SUBTOTAL
Subtotal equipment, labor and tax
5 133,758.91
I
FREIGHT
Freight forone IUK AST, three Wayne dispensers
S 1,997.A0
GRAND TOTAL
S 135.99731
Standard EZ Fuel/BluelUSA/NJPA terms and conditions apply. AST FOB factory. Pricing does not include any applicable sales tax or freight. Any applicable sales tax
and freight will be added to finial invoice. AST WIN come with factory shop drawings for permitting purposes. Proposal does not include any stamped engineered
drawings of tank, engineered electrical, engineered concrete, engineered site plan etc.
Quoted prices are being honored for 30 days with the additional caveat, "material prices are subject to adjustment; without mark up, based on increases occurring
between the time of this quote and receipt of order."
Puregreen Equipment/ DBA EZ Fuel-BlueIUSA AGREED, City of Fayetteville, AR
AT/F41"� � Lione i Jordan
Printed a e Fr to ame
`i1/ J , r ._.I/
V
Mayor 9.18.18
Title Date Title Date
1650 Horizon Pkwy #450 Buford, GA 30518 (770) 232-9090 www.bluelusa.com
[2]
F. fill IE:l.
., rr.. ,...,,..
EZ Fuel "City of Fayetteville, AR
Location: 1525 S. Happy Hollow Road Date: B-9-2018
boscrlpllon City of Fayetteville Hootan EZ Fuel
Supply AST System. Dna 10,000 gallon Flameshiekf AST, Red Jacket 1131,11P submersible pump, 2" ball valve, 2* solenoid
Obtain ell local and state AST Permits (as required) 8 any applicable. Provide copies of all permits to EZ Fuel before any
she work begins.
x
valve, 2' emergency valve, Morrison overfill valve and swing check valve
x
Filing of AR paperwork with slate x
Supply one twin hose Gasboy electronic 22GPM rot gas and one two time 36GMP diesel dispenser. New 314-x 10' hoses,
x
Supply 2' piping to install STP and accessories to existing City of Fayetteville bunk line
X
swivel breakaways and automatic nozzles for gas and 1" same for diesel
x
ELECTRICAL+ CONDUITS 'Ali installations to comply with NFPA30, 30Aend NEC code
Train Local personnel. Checklist must be signed by Terminal Manager_
Reuse existing Fuelmasler fuel management console
x
lit is assumed City of Fayetteville existing electrical for ASTs, dispensers and fuel management is up to code.
x
SITE WORK
Obtain ell local and state AST Permits (as required) 8 any applicable. Provide copies of all permits to EZ Fuel before any
she work begins.
x
Assist in AR registration paperwork. Must be submitted by owner,
x
Filing of AR paperwork with slate x
Perform any testing of equipment that may be required by local or slate agencies (pressure test for example)
x
Supply 2' piping to install STP and accessories to existing City of Fayetteville bunk line
x
Supply additional piping to connect existing fill box to now 10,000 gallon new lank New overMl valve and swing check valve
will need to be Installed.
x
ELECTRICAL+ CONDUITS 'Ali installations to comply with NFPA30, 30Aend NEC code
Train Local personnel. Checklist must be signed by Terminal Manager_
Disconnect existing conduit and power wiring. Install additional new condu t and wire for now lank
x
lit is assumed City of Fayetteville existing electrical for ASTs, dispensers and fuel management is up to code.
x
Remove two existing mechanleal dispensers and install now electronic dispensers. I will be assumed all work will be above
shear valve. No repairs to existing Chy of Fayetteville sumps, electrical are Included.
Fake digital photos of completed project from all angles (10 photos minimum) and emati to cmilchell@bluelusa.com
Confirm proper circuit breakers are being used
x
INSTALLATION & START-UP
AIi work performed must comply with NFPA 30,30& NEC, and other applicable code,
x
Provide qualified technician to complete system start-up.
x
Obtain all local and stale AST Pemdls (as required) & arty applicable AST Registration.
x
iC xirdlnale all required inspections by local jurisdiction.
x
Install any exls6ng tank monitor onto new tank
x
Provide Crane
x
Coordinate (with FZ Fuel, City of Fayetteville, Houten) Crane and sat tank. x
x x
Check all piping, fillings, S unions for leaks. �ighlan where necessary.
x
Purchase and Order fluid for all tanks x
Coordinate in'dial fuel delivery. Technician MUST be on site during delivery to check for leaks. All piping and unions should x
be tightened before.
x x
'Calibrate Clock Gauge and alarm on AST
x
Install working vent (FZ Fuel supplied).
x
Test and Calibrate STP and dispenser(s).
x
Test and start up Card Reader
x
Troubleshoot all wiring, communication and start-up issues to completion.
x
Test Emergency ShLdofL -
x
Touch up all nicks, scratches, and exposed threading as best possible.
x
Train Local personnel. Checklist must be signed by Terminal Manager.
x
Clean fuel island area of all debris.
x
Take digital photos of completed project from an angles (10 photos r imimum) and email to cmitchell@bluelusa.com
x
Provide copies of all local and stale finial sign off documents for project
x
DEF TOTE CABINET INSTALLATION & START-UP
(Provide one Bluel USA late cabinet with built in dispenser- electro mechanical pulse output 48'w x 961 x 8M
x
'Obtain all local and stale AST Permits (as required) 8 any applicable AST Registralim
x
Unload with fork lin and set tole cabinet on level pad. Protectwith two bollards at end of tole cabinet
x
(Run conduit and wire 110VAC 20 amp service to J box on outside of cabinet. Pull authorization and pulse wiring from
Gasboy Islander to tole cabinet
x
(Load City of Fayetteville supplied tole
x
x
Train Local personnel. Checklist must be signed by Terminal Manager_
x
Clean fuel island area of all debris.
x
Fake digital photos of completed project from all angles (10 photos minimum) and emati to cmilchell@bluelusa.com
x
Provide copies of all local and stale finial sign off documents for project
x
Ex r-1-1CL ; . i
.......Tri.„r..,.�, C;
EZ Fuel -City of Fayetteville, AR
Location: Church Street "uptown” Date: 8-9-2018
Description City of Fayettoville Houten EZ Fuel
EQUIPMENT
Supply One electronic single hose suction pump. New 314` x 10' hoses, swival breakaways and automallc nozzles x
Reuse existing Fualmesterfuel management console x
SITE WORK
'Remove existing mecharecet dispenser and replace with new Wayne electronic dispenser x
Ail vvtkwin be above shearvalve x
ELECTRICAL ♦CONDUITS *All installations to comply with NFPA3D, 3DAand NEC code
Disconnect existing conduit and power wiring
x
It is assumed City of Fayetteville existing electrical for dispensers and fuel management is up to coda.
x
'Remove one existing mechanical dispensers and install now electronic dispensers. I will be assumed all work win be above
shearvaNe. No repairs to existing City of Fayefteville sumps, electrical are included.
x
Confirm proper circuit breakers are being used
x
INSTALLATION & START-UP
hll work performed must comply with NFPA 30,30A, NEC, and other applicable code. X
(Provide qualified technician to complete system start-up. x
No permits are included, workirig with existing etecirical with no modifical ons. Any permits will be billed cost plus x
Check all piping, fittings. 8 unions for leaks. Tighten where necessary, x
Test and Callbrale dispemar(s). X
Test Card Reader communications x x
Train Local personnel. Checklist must be signed by Terminal Manager. x
'Clean fuel island area or all debris. I I x
Take digllal photos of completed pfolw from an ang:es ( 10 photos minimum) and email to cmilchen@b'.ueIusa,wrn I I x