Loading...
HomeMy WebLinkAbout147-12 RESOLUTIONRESOLUTION NO. 147-12 A RESOLUTION AWARDING BID #12-42 AND AUTHORIZING THE PURCHASE OF ONE (1) POWER GENERATOR FROM ENDLESS POWER CORP. IN THE AMOUNT OF $61,330.00, PLUS APPLICABLE SALES TAX, FOR USE AT THE OWL CREEK LIFT STATION, AND APPROVING A BUDGET ADJUSTMENT BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE, ARKANSAS: Section 1. That the City Council of the City of Fayetteville, Arkansas hereby awards Bid #12-42 and authorizes the purchase of one (1) power generator from Endless Power Corp. in the amount of $61,330.00, plus applicable sales tax, for use at the Owl Creek lift station. Section 2. That the City Council of the City of Fayetteville, Arkansas hereby approves a budget adjustment, a copy of which is attached to this Resolution as Exhibit "A". PASSED and APPROVED this 17th day of July, 2012. APPROVED: ATTEST: AN, Mayor By: 40I1 CCS SONDRA E. SMITH, City Clerk/Treasurer Q��eennr4C/T' rr�y� �tR'�., a�®c) � a ° ° s . °°•G\lY • •�® vV• •fie .- :FAYETTEVILLE: *iiy° ° o !'�ureauue��� City of Fayetteville, Arkansas Budget Adjustment Form V11.0222 Budget Year 2012 Division: Wastewater Treatment Plant Department: Utilities Director Request Date 6/29/2012 Adjustment Number BUDGET ADJUSTMENT DESCRIPTION / JUSTIFICATION A BA is needed to transfer $80,832 from Fleet into the WWTP - Upgrade/Replace Lift Stations Project for the Owl Creek Lift Station back up generator. The existing back up power generator experienced a critical failure and parts to repair the generator are no longer available. The back up generator is required by our NPDES permit and provides critical back up during power outage episodes thus preventing possible sewer overflows. The new power generator will replace Unit# 9021. The funds being transfered are the replacement charges that fleet has collected thus far on Unit# 9021. Division Head .. d�- lector A Aar Depart] I ire; � Fina ce Iirec or Date I y?J/2 Date Zctgui.(2 Date .7 - Chef of Staff Prepared By: Cheryl Partain Reference: bfel! Budget & Research Use Only Type: A B C D E P General Ledger Date Posted to General Ledger Checked / Verified Initial Date Initial Date Account Name TOTAL BUDGET ADJUSTMENT Account Number 161,664 161,664 Increase / (Decrease) Project.Sub Expense Revenue Number Use of fund balance 9700.0970.4999.99 Transfer to Water & Sewer 9700.1920.7602.40 80,832 80,832 07032. 2012 Transfer from Shop 5400.0940.6602.70 Fixed assets 80,832 02068 1 5400.5800.5801.00 80,832 02068 1 C:\Users\aatha\AppData\Local\Temp\XPgrpwise\BA - Owl Creek Lift Station Generator David Jurgens Submitted By City of Fayetteville Staff Review Form City Council Agenda Items and Contracts, Leases or Agreements 17 -Jul -12 City Council Meeting Date Agenda Items Only Wastewater Treatment Division Action Required: Utilities Department Approval of the purchase of a replacement back up power generator for the Owl Creek lift station from Endless Power Corp. for $61,330.00 plus sales tax, per Bid 12-42, and approval of a budget adjustment of $80,832.00. 67,004 Cost of this request 186,547 Upgrade/Replace Lift Stations-WWTP 5400.5800.5801.00 $ Account Number 02068.1 Project Number Budgeted Item Category / Project Budget Program Category / Project Name 156,644 Wastewater Treatment Plant Funds Used to Date Program / Project Category Name 29,903 Water/Sewer Remaining Balance Fund Name Budget Adjustment Attached Dep ent 'rector City A Van) 17.- Date ZDate -2T-(Z Date Finance and Internal ervices Director Date ate X Previous Ordinance or Resolution # Original Contract Date: Original Contract Number: Received in Cit 2'� 1 2 P 1 2 : 04 IWO, Clerk's Office Comments: Revised January 15, 2009 Ta'teevi�e CITY COUNCIL AGENDA MEMO MEETING DATE OF JULY 17, 2012 THE CITY OF FAYETTEVILLE, ARKANSAS ARKANSAS www.accessfayetteville.org To: Fayetteville City Council Thru: Mayor Lioneld Jordan Don Marr, Chief of Staff From: David Jurgens, Utilities Director V Fayetteville Water and Sewer Comm Date: June 27, 2012 Subject: Purchase of backup power generator for Owl Creek sewer pump station, Endless Power Corporation RECOMMENDATION Staff recommends approval of the purchase of a replacement back up power generator for the Owl Creek lift station from Endless Power Corporation for $61,330.00 plus sales tax, per Bid 12-42, and approval of a budget adjustment. BACKGROUND The existing back up power generator was installed in January 2000. This generator experienced a critical failure and the unit's original equipment manufacturer is no longer in business. The exciter, which controls the magnetic field and controls the power output in the generator system, failed and the parts to replace the exciter are no longer available. The repairs would entail removing and modifying the body of the generator at an approximate cost of nearly $20,000, and would create unpredictable risks that associated with the major modification of the generator. The Owl Creek lift station pumps approximately 260,000 gallons a day of wastewater from the west side of Fayetteville. The backup generator is required by our NPDES permit, and provides the critical back up during power outage episodes thus preventing possible sewer overflows. DISCUSSION The City received bids May 11, 2012. After much research, it was determined that the low bidder's product meets all City specifications. The generator will be installed by City and CH2M Hill staff. Vendor Quantity Price Each Total Bid Price Endless Power Corp. 1 $61,330.00 $61,330.00 Clifford Power Systems — Option 2 1 $63,150.00 $63,150.00 RP Power, LLC. 1 $63,810.00 $63,810.00 Clifford Power Systems — Option 1 1 $65,045.00 $65,045.00 Taylor Power Systems 1 $70,287.00 $70,287.00 Leete Generators 1 $73,615.00 $73,615.00 United Engines, LLC. 1 $74,050.00 $74,050.00 Cummins Mid -South, LLC. 1 $94,368.00 $94,368.00 BUDGET IMPACT The original generator was trailer mounted and thus a fleet item that accumulated replacement charges. The new generator is skid mounted for a fixed installation, and will not be a Fleet item. The budget adjustment transfers the accumulated replacement funds to the Wastewater Treatment capital project 02068. Telecommunications Device for the Deaf TDD (479) 521-1316 113 West Mountain - Fayetteville, AR 72701 RESOLUTION NO. A RESOLUTION AWARDING BID #12-42 AND AUTHORIZING THE PURCHASE OF ONE (1) POWER GENERATOR FROM ENDLESS POWER CORP. IN THE AMOUNT OF $61,330.00, PLUS APPLICABLE SALES TAX, FOR USE AT THE OWL CREEK LIFT STATION, AND APPROVING A BUDGET ADJUSTMENT BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE, ARKANSAS: Section 1. That the City Council of the City of Fayetteville, Arkansas hereby awards Bid #12-42 and authorizes the purchase of one (1) power generator from Endless Power Corp. in the amount of $61,330.00, plus applicable sales tax, for use at the Owl Creek lift station. Section 2. That the City Council of the City of Fayetteville, Arkansas hereby approves a budget adjustment, a copy of which is attached to this Resolution as Exhibit "A". PASSED and APPROVED this 17th day of July, 2012. APPROVED: ATTEST: By: By: LIONELD JORDAN, Mayor SONDRA E. SMITH, City Clerk/Treasurer 80E01, /L pasinaa :aa6eueyj yoledsla :aa6eueyj sagllllfl 0 0 (D Finance & Internal Services Director: :aa6eue j le6png :aoloaga luewpedea :ie6euelAj 6uiseyo.ind a 7.3O N y : suollonalsu I leloadg 0 <0 COJ O) co 3 6wlpueH/6ulddlgS _< S d o Cr 0 fa Z! 0 a 0 - .., r o CD 3 W 0) 0) eT M 0 0 3i O W g 0 (D O O 0 0) 0 c enssi jo;lug rn w W 0 0 O c C) 0 to O O O O O O O O O O O O O 0 lsoo pepuelx3 0 CD .0 � N O N • • Z C) oA 0 O 0 co 0. O r 00' L089'0099'00I S saegwnN lun000y N -o 0 oN W 0 0 O O. m m 0. 0 0 N N O 0 O n H 0 ° Zi N ID 0 'Q -0 ,C Of SI) 0.0. tr co O 1 0 • O C• d rt ., ti .0 O n C m Q C.)y'0 0) v C 3 m n 9 wm. _ w0 ' V3 CDA 0 414 FL es A n c CD k N suy 0 0 ER EN = ca V Nco 0) O V W WW O C C W O W O a 0 co a 0 (D 0 N A m co co 7 y # gassy pexi Z 0 :JegwnN O'd :.oN uoilislnba?A Z 0 peyoeuy salon° aye eviIle BIDDER 1 Clifford Power Systems - Option 1 Bid 12-42, Generator anufacturer and Model Generac SG0200KG20129N18HPLYE BID: 12-42 DATE: 05111/12 TIME: 2:00 PM CITY OF FAYETTEVILLE $65,045.00 2 Clifford Power Systems - Option 2 Generac SGO200KG20129N18HPLYE $63,150.00 3 Cummins Mid -South, LLC. Cummins 250GFBC $94,368.00 4 Endless Power Corp. Baldor IGLC210-2N $61,330.00 5 Leete Generators Generac SG0200 $73,615.00 6 RP Power, LLC. Kohler 200REZXB $63,810.00 7 Taylor Power Systems Taylor Power TG200 $70,287.00 8 United Engines, LLC. MTU Onsite Energy GS00200N6SRAS0984 $74,050.00 *NOTICE: Bid award is contingent upon vendor meeting minimum specifications and formal authorization by City officials. CERTIFIED: P. VICE, PURCH MGR fditkalg; WITNESS • City of Fayetteville, Arkansas Purchasing Division — Room 306 113 W. Mountain e Fayetteville, AR 72701 Phone: 479.575.8220 ARKANSAS TDD (Telecommunication. Device for the Deaf): 479.521.1316 INVITATION TO BID: BID 12-42, Generator DEADLINE: Friday, May 11, 2012 before 2:00 PM, Local Time DELIVERY LOCATION: Room 306 —113 W. Mountain, Fayetteville, AR 72701 PURCHASING AGENT: Andrea Foren Rasco, CPPB, CPPO, aforen(a ci.fayetteville.ar.us DATE OF ISSUE AND ADVERTISEMENT: Saturday, April 21, 2012 INVITATION TO BID Bid 12-42, Generator No late bids will be accepted. Bids shall be submitted in sealed envelopes labeled "Bid 12-42, Generator" with the name and address of the bidder. All bids shall be submitted in accordance with the attached City of Fayetteville specifications and bid documents attached hereto. Each bidder is required to fill in every blank and shall supply all information requested; failure to do so may be used as basis of rejection. The undersigned hereby offers to furnish & deliver the articles or services as specified, at the prices & terms stated herein, and in strict accordance with the specifications and general conditions of bidding, all of which are made a part of this offer. This offer is not subject to withdrawal unless upon mutual written agreement by the Proposer/Bidder and City Purchasing Manager. Name of Firm: k j/DI,FS5 0)/2%? Contact Person: u i D T5 -i. Title: Pres, E -Mail: CAfa ea -655 pbu.erCcd)e. CPl /,t( Phone: Sd /- 5t'- /5/ 5— Business Address: D -x,52) Ow( 36 s- /V. City: State: j/// Signature: ld,S Date: Zip: 7..//3 City of Fayetteville, AR Bid 12-42, Generator Page 1 of 11 City of Fayetteville Bid 12-42, Generator Bid Form DATE REQUIRED AS A COMPLETE UNIT: 60 days from Date of Order *GUARANTEED DELIVERY DATE: & 0 Day 5 Pio vW F.O.B. 630 N. Double Springs Road, Fayetteville, AR 72704 ITEM: DESCRIPTION: 1. Standby Generator Please Specify for Unit(s) Bid: *MANUFACTURER: QUANTITY: *PRICE EACH: *TOTAL PRICE Db 1 $ 6,330 $ CI, 330 3 1,4 -1 -De, *MODEL: CrLC 01.)e) —4/ Bids must be submitted on this bid form in its entirety AND accompanied by descriptive literature on the products being bid. EXECUTION OF BID - Bidders are requested to indicate by check mark or "Yes/No" on each line of the Technical Specifications the compliance of the item bid. Actual specification of any deficient item must be noted on the bid sheet or separate attachment. If specifications of item bid differ from provided literature, deviation must be documented and certified by the manufacturer as a regular production option. Upon signing this Bid, the bidder certifies that: 1. He/she has read and agrees to the requirements set forth in this proposal, including specifications, terms, standard conditions, and any pertinent information regarding the articles being bid on. 2. Unless otherwise noted and explained, the unit bid and listed meets or exceeds all of these requirements as specified by The City of Fayetteville. 3. The Bidder can and will comply with all specifications and requirements for delivery, documentation and support as specified herein. Unsigned bids will be rejected. Items marked * are mandatory for consideration. Pc) //t) ER La/2A *NAME OF FIRM: I4/bL -S 5 *BUSINESS ADDRESS: ;:a.S..Z 1141.17 3 Purchase Order/Payments shall be issued to this name *STATE: 11 *ZIP: 7�- *CITY: !,i , TTIi2 i/. *PHONE: 5O(_ �5'/ / �J S FAX: )--6 7- ‘ (7--3 58, *E-MAIL: 00,44,/GY 1440 SS A , 24-1 *BY: (PRINTED NAME) )4t) )4'l ` SS 0 *AUTHORIZED SIGNATURE: *TITLE: City of Fayetteville, AR Bid 12-42, Generator Page 2 of 11 City of Fayetteville Bid 12-42, Generator Technical Specification Description: Stand-by Generator Specifications (replacement generator) Location: Owl Creek Lift Station (LS #22) Address: 630 N. Double Springs Road, Fayetteville, AR 72704 This bid is for the purchase of the generator only. Installation will be by the City or its designated representative. Generator purchased shall produce 480V 3-phase power and it will supply adequate power during an emergency power outage or when the electrical company is repairing transformers and or lines, fuses. The existing lift station has a switch gear in place and is rated at 400 kW. Generator will be installed by others at an existing lift station. The standby system will be coordinated so not to interfere with the lift station operation. 1. GENERAL: - 1.1 All unit(s) bid shall meet or exceed the minimum requirements or they will be deemed incomplete and will not be considered for bid award. 1.2 All specifications written are to minimums, unless otherwise noted. 2. MANUFACTURER / MODEL: - 2.1 Unit(s) bid shall be new standard production model as offered for commercial trade. 3. ITEM 1— GENERATOR: A. Generator shall be 200 kW Standby; 185 kW prime; 480/277V generator. B. Deliver the project, as described in this exhibit, including: 1. Generation Equipment 2. Equipment and Installation Warranties 3. In -Service Training C. The generation equipment shall include: 1. Engine Generator set rated at 480V/277V; 200 kW (standby); 185 kW (prime), 0.8pf lagging; 250 KVA, 1800 RPM max 2. Permanent Magnet Generator 3. Electronic Engine Governor 4. Charging Alternator 24V 5. 24V Lead Acid Batteries, Rack and Battery Charger 6. Engine Cooling System 7. Exhaust System with Silencer City of Fayetteville, AR Bid 12-42, Generator Page 9 of 11 8. Fuel source as Natural Gas 9. Sound Attenuated Enclosure (maximum 71 dBA at 7 meters) 10. Block Heater 11. Lubricating Oil and Antifreeze- Initial fill 4. WARRANTY: A. The entire unit shall be warranted for a minimum of two years or 1500 hours period from the start-up date. B. Warranty shall include all parts, labor, and transportation of parts to and from the location of the warranty service center C. Awarded vendor shall be responsible for warranty administration of entire unit 5. DELIVERY/ DOCUMENTATION: A. Units shall be delivered F.O.B. to the Owl Creek Lift Station (LS #22), located at 630 N. Double Springs Road, Fayetteville, AR 72704 , for compliance review and final acceptance B. Units shall be fully assembled, serviced, and ready for operation as delivered. C. Delivery shall be coordinated with the City in advance of the unit being delivered. 6. TRAINING: A. Onsite in-service service training will be provided to the City's Contract Operator's staff on the operation and maintenance of the generation equipment. In-service training shall include any commissioning services necessary to validate the equipment warranty. 7. OPTIONAL PRICING (will not be considered for bid evaluation): A. All bidders should provide the following optional pricing, as listed below, to be purchased at the City's discretion. Optional pricing shall not be considered in bid evaluation. 1. Description for annual maintenance (provide below): 00 2. Cost for annual maintenance: $ ROC Price per year City of Fayetteville, AR Bid 12-42, Generator Page 10 of 11 -City of Fayetteville Bid 12-42, Generator Statement of Disclosure — To Be Submitted With ALL Bids This page does not count towards page limitations set forth in this request for proposal or bid. Proposer must disclose any possible conflict of interest with the City of Fayetteville, including, but not limited to, any relationship with any City of Fayetteville employee. Your response must disclose if a known relationship exists between any principal or employee of your firm and any City of Fayetteville employee or elected City of Fayetteville official. if, to your knowledge, no relationship exists, this should also be stated in your response. Failure to disclose such a relationship may result in cancellation of a purchase and/or contract as a result of your response. This form must be completed and returned in order for your bid/proposal to be eligible for consideration. PLEASE CHECK ONE OF THE FOLLOWING TWO OPTIONS, AS IT APPROPRIATELY APPLIES TO YOUR FIRM: 1.) NO KNOWN RELATIONSHIP EXISTS 2.) RELATIONSHIP EXISTS (Please explain) PLEASE FILL OUT THE SECTION BELOW AND SUBMIT THIS FORM WITH YOUR BID OR PROPOSAL: 1.) I, as an officer of this organization, or per the attached letter of authorization, am duly authorized to certify the information provided herein are accurate and true; and 2.) My organization shall comply with all State and Federal Equal Opportunity and Non -Discrimination requirements and conditions of employment. 'Mt o�t� SSS Signature 56///e). Dat City of Fayetteville, AR Bid 12-42, Generator Page 11 of 11 ELJDOlR A MEMBER OF THE ABB GROUP Configurator Submittal Package ENDLESS POWER CORP Quote Number: 156466743-10 Project ID: City of Fayetteville Project Description: CUSTOMGENSET - IGLC2102N Copyright © All Submittal Package information within this document is subject to Baldor Electric Company copyright © protection, unless otherwise noted. M A A:K GENE RATORS InteliLite NT Genset Controller Introduction The InteliLite NT controller provides complete monitoring and protection for the Genset in manual or remote start mode. Provides remote control, user configuration and complete gen-set monitoring and protection. The control features a powerful graphic display providing userfriendly information in an easy to understand format. Real time clock and event history log are valuable for troubleshooting. Instrumentation of internal values on VDO type analog gauges makes use easy even for untrained personnel. • Controller is UL and ULC recognized • Controller is NFPA110 compliant • Front panel protection is IP65 • Large easy to read graphic LCD display • LED's provide visual status information • Password protection • History log for rapid fault isolation • Complete Engine, Alternator, Utility Line monitoring • Optional Remote Keypad/Display • Optional Remote Annunciator LED Indications. Standard Features • Microprocessor based • Secure settings with easy to use password protection • Engine Protection features • Generator Protection features • Real Time Clock with Battery back up • Event and performance log - Event based history with 119 events - Reason, Data and Time + all important values - Test Run scheduler • User interface - Graphic 128 x 64 pixels LCD display - Multiple language capability - Setpoints adjustable at keypad or PC - Keypad provides tactile feedback • Inputs and outputs - 3 configurable analog inputs - 7 Digital inputs - 7 Digital outputs - Magnetic RPM pick-up input - D+ preexcitation terminal • EFI engine support - Engine specific CAN J1939 EFI engine support - Diagnostic messages in plain text • RS -232 lnterface ALARM Indicates active or inactive, but still not reset shutdown alarm WARNING Indicates active or inactive, but still not reset warning alarm NOT IN AUTO Indication the controller in not in AUTO mode READY/AUTO Indicates the controller is in AUTO mode and is ready to operation. The LED goes off after the engine is started. RUNNING Indicates running engine SUPPLYING LOAD Indicates the gen-set is running, giving proper voltage and frequency and the outputs Read to Load, GCB close/open are closed. Engine Application Data Alarm List (WRN=Warning; SD=Shutdown) Events Description Oil Press Wm Oil pressure is less than setpoint. Oil Press Sd Oil pressure its less than setpoint. Eng Temp Wm Water temperature exceeds setpoint. Eng Temp Sd Water temperature exceeds setpoint. Fuel Level Wm Fuel level is less than setpoint. Fuel Level Sd Fuel level is less than setpoint. Vbat Wrn Battery volts is out of limits. AnInIOM Wrn Anin condition for IG-IOM/IGS-PTM. AnInlOM Sd Arlin condition for IG-IOM/IGS-PTM. Digital IN Wrn Digital Input condition Wrn/Sd Battery Fail Batt fail during start sequence. Start fail Sd GENSET start failed. ParamFail Wrong memory checksum. Vgen <, > Sd Output volts is out of limits. Vgen unbl Sd Output volts is unbalanced. Fgen <,> Sd Output freq is out of limits. Igen unbl Sd Output current is unbalanced. Overload Sd Output current exceeds setpoint. Overspeed Sd RPM exceeds setpoint. Underspeed Sd After start, RPM is less than setpoint. EmergStop Sd Emergency stop is opened. GCB fail Sd Generator circuit breaker failed. Pickup Fault Sd Speed sensor failed. Stop fail Sd Genset stop failed. NextService Wrn The NextServTimer expired. ChrgFail Wrn Alternator failed to charge battery. SprinklActive Wrn Active if Sprinkler output is closed. RA15 fail Wm Lost connection to IGL-RA15 module. IOM fail Sd Lost connection to IG-IOMAGS-PTM. ECU Alarm Wrn ECU alarm list is not empty. LowRTCBatt Wrn RTC backup battery is flat. Monitored Parameters Generator Protection • Over/Under frequency • Over/Under voltage • CurrentNoltage asymmetry • Overcurrent/Overload • Short Circuit Current detection • True RMS Voltage measurement - Phase to Phase; - Phase to Neutral - PT ratio range 0.1-500 • True RMS current measurements - Current range 5 A - Maximal measured current 10 A - CT ratio range 1-5000 • Power measurements - Act / React Power and Power, - Power Factor per phase - Active and Reactive Energy counter Engine Protection • Oil Pressure • Coolant Temperature • Fuel Level • Engine RPM • Battery Condition • Time to Next Service • Total Operating Hours • J1939 communications with ECU Timers • Pre Start Delay • Maximum Crank time • Pause time between crank attempts • Idle time • Stabil Time, Gen voltage output stabil time • Gen Circuit Breaker (GCB) Close delay • Cooling Time, unloaded Genset cool time • After Cool Time, run cooling pump after stop • Stop Time • Hom Timeout E3_A T JDO1% GENERATORS O t6 a) c a) 0 E O N U 0 0 0 (0 0 u) is a) ua E z Z 0 a) rT m U t9 0 E .n O Q7 O) O U Specifications Power Supply Voltage 8-36VDC Current 40-430mA depends voltage and temp Volts tolerance 2 % at 24V Ambient Operating temp -20 to +70°C Storage temp -30 to +80°C Protection type IP65 Humidity 95% no condensation Low Voltage Directive EN 61010-1:95 +A1:97 Electromagnetic Compatibility EN 50081-1:94, EN 50081-2:96 EN 50082-1:99, EN 50082-2:97 Vibration 5 - 25 Hz, ±1,6mm 25-100Hz,a=4g Shock a = 200 m/s2 Generator Frequency 50-60 Hz Freq Tol. 0.2Hz Current Monitor IC nominal (from C1) 5A Load (CT Zout) <0.10 CT input burden <0.2 VA per phase (In=5A) Measurement tolerance 2% of Nominal !max from CT 10A (peak from CT 150A/ 1s !max continuous 12 A Voltage Monitor Voltage range 0 - 277 VAC phase to neutral 0 - 480 VAC phase to phase Vmax 340 VAC phase to neutral 600 VAC phase to phase Input Resistance 0.6 MO phase to phase 0.3 MO phase to neutral Measurement tolerance 2% of Nominal Overvoltage class III / 2 (EN61010) Digital Inputs/Outputs Number of In/Outputs 7 / 7 Voltage Range 0-36 VDC Input Resistance 4.2 k0 Volts for closed indication 0-2VDC Volts for open indication 8-36VDC Max Output Current 0.5A Analog Inputs Number of inputs 3 Resolution 10bits Range (jumper) V, Ohm (default), mA Volts range 0-2.5V Ohms range 0-25000 mA range 0-20mA Input impedance > 100 kO for V measuring 180 0 for mA measuring 0 tolerance t 2 % ± 2 0 of measured value V tolerance t 1% a 1 mV of measured value Speed Pick Up Sensor Type magnetic pick-up (shielded cable) Vin Minimum 2 Vpk-pk (from 4 Hz to 4 kHz) Vin Maximum 50 Veff Freq min 4 Hz Freq max 10 kHz (min. input voltage 6Vpk-pk) Freq tolerance 0.2 % D+ Function !max output 300mA Guaranteed level for signal Charging OK 80% of supply voltage Horn Output Volts 0-36VDC Current 1A maximum EI.ALJDOR GENERATORS Optional Expansion Modules and Accessories IGL-RAI5 • Remote Annunciator • Customizable Label • 15 LED's - Can be programmed Red, Green or Yellow • Lamp Test • Local Horn Button • Connect via Can Bus • Can be used stand alone, or with an IGS-PTM or IGS -IOM IGS -IOM • VO Extension Module • 8 Binary Inputs, 8 Binary Outputs, 4 Analog Inputs, 1 Analog Output . Measures PT 100 and M 100 sensors • Analog Inputs: 0-2500 Ohms • Analog Outputs- 0-20 mA • Connect via J1939 Can Bus • Can be used with a IGL-RA 15 • If this extension module is used, the IGS -ATM cannot be used IL -NT AOUT8 • Slide in card • Connect to standard VDO, Datcon, or similar type gauges • UP to 8 gauges can be connected Stop l Binary Inputs 6 r IGS-PTM • I/O Extension Module • 8 Binary Inputs, 8 Binary Outputs, 4 Analog Inputs, 1 Analog Output • Measures PT 100 and NI 100 sensors • Analog Inputs: 0-250 Ohms, 0-100mV, 0-20 mA • Analog Outputs- 0-20 mA • Connect via J 1939 CanBus • Can be used with a IGL-RA 15 • If this extension module is used, the IGS -IOM cannot be used IL -NT RD • Remote Display • Connects to RS -232 Interface . If this function is used, the IG -IB cannot be used IG -IB • Internet Module • Connect via Ethernet or Dial-up . Control Via Internet • Full 2 way communication • If this module is used, the IL -NT RD cannot be used Options PC Modem L Alarm IL -NT RD IG -IB 1 Choose one Device /4 1G - IOM Engine Control Binary Outputs (Open Collector) RS232 Interface I Plug In Module IGS- PTM ©©©© Choose one Device ©©©© t IGL- RAI5 — t J 8 Gauge Drivers Plug In Module L InteliLite NT GENSET Controller Generator Control Optional CAN 31939 I/O Extension 9A -T --TOR GENERATORS WORLD HEADQUARTERS Baldor Electric Company • P. O. Box 2400 • Fort Smith, AR 72902-2400 U.S.A. Phone (479) 646-4711 • Fax (479) 648-5792 • International Fax (479) 648-5895 www.baldorcom ® Baldor Electric Company Printed in U.S.A. FM24108 10/08 FARR 2000 MAX -MOM High Performance Enclosure (HPE) GENERATORS Genset Enclosure High Performance Enclosure HPE Weather resistant enclosures with sound attenuating material are highly engineered and are the result of many years of experience in the standby generation markets. HPE Type Noise Reduction Silencer Grade ®3m @7m Level 0 3dbA 5dbA Industrial Levels 15dbA 25dbA Critical Level 2 25dbA 32dbA Hospital Protective Coating The walls and roof are finished with DuPont Powder Coating No. PFf500S8, Almond color, TGIC-Polyester, electrostatically applied enamel -based powder paint 1.5 to 2.5 mil. thickness that is baked at 400°F for 15 minutes. This provides a durable weather resistant finish that will protect your investment for many years to come. Noise Measurements Noise measurements are taken at 3 meters (and 7m) from the enclosure as indicated in this figure. The Genset exhaust hood is position #1. .4- 3m r -7m Standard Features (All Levels) • Roof and wall sections are 14 gauge ASTM A569 hot rolled steel with #4 finish • Modular construction allows flexibility to meet various field conditions including reversing door swing, adding or moving doors, or adding sound attenuating hoods. • Wall sections use overlapping flanges that are bolted together and to the base rail with SAE grade 5 bolts with Nylock® or Rivnut® fasteners or equivalent. • Roof, wall and door sections are no more than 42 inch wide with folded flanges of no less than 2-N4 inch to prevent moisture from entering the genset area and can withstand up to 120 MPH wind Toad. • Weather resistant drip proof construction include a roof section load rating of 25 lb/ft2 with 1 inch overhung drip edge and rain gutters over all doors and openings to maintain less than 0.01 ounces of moisture penetration per square foot of louver free area during a 4 inch per hour rainfall. • Grade 2 hardware kit includes zinc plated fasteners, zinc plated cast aluminum keylock door handles, and heavy duty stainless steel hinges with removable brass pins. • Heavy duty door gaskets are made from non -hygroscopic rubber to prevent doors from freezing shut during inclement weather. • Structural steel frame includes spring vibration isolators between genset and base to decouple genset from enclosure mounting points. Frame includes integral lifting points capable of lifting the genset with the enclosure without damage. • Internal stub up area is provided for easy access to power cabling and fuel supply connections. Construction The bolt together modular design is superior to a welded box. Sections may be removed for service of major components. Hinges Stainless steel butt hinges with removable brass pins are long lasting and easy to open or close for routine maintenance. Latch Heavy duty, single -point latches are durable and easy to use. Handle Lockable L -type door handles are keyed alike, easy to use and provide security. Configurator Submittal Package - Quote Number: 156466743-10 - Custom Generator Standard Features, HPE Level 0 In addition to the "Standard Features (All Levels)" the following additional features are also included for the Level 0 Enclosure: • Weather Resistant Enclosure • Noise reduction 3dBA at 3 Meters • Unit Mounted Radiator suitable for 40°C Ambient • External mount Industrial Grade silencer. Silencer is mounted above the enclosure roof using heavy duty powder coated brackets. Integral rain shield is included on exhaust pipe to enclosure opening to divert rain and debris away from the genset area. • Fixed Louvers for Cooling Air Intake are made of mil finished aluminum. Louvers divert rain and debris away from the genset area and include a bird and debris screen. • Punched Screen Air Discharge barrier is mounted in front of the unit mounted radiator to protect from birds and debris. Air discharge barrier is made of the same enclosure material to complement the genset exterior. 600 to 2000kW See Data Sheet for dimension information. (http://www.baldor.com/products/generators/idlc.asp) Standard Features, HPE Level 1 • Sound Attenuated Enclosure • Noise reduction 15dBA at 3 Meters • Unit Mounted Radiator suitable for 40°C Ambient • External mount Critical Grade silencer. Silencer is mounted above the enclosure roof using heavy duty powder coated brackets. Integral rain shield is included on exhaust pipe to enclosure opening to divert rain and debris away from the genset area. • Fixed Acoustic Louvers for Cooling Air Intake are made of mil finished aluminum exterior with fiberglass insulation and perforated aluminum on interior facing surface. Louvers divert rain and debris away from the genset area and include a bird and debris screen. • Air Discharge Hood is mounted in front of the unit mounted radiator and includes an integral Punched Screen Barrier to protect from birds and falling debris. Discharge Hood is lined with acoustic foam insulation and includes a rain gutter to channel water away from the genset interior. Discharge hood and barrier is made of the same enclosure material to complement the genset exterior. • Sound Deadening Interior Surface is designed with 3 inches of thermoset fiber material set between the exterior wall and a perforated mil finished aluminum interior wall. See Data Sheet for dimension information. (http://www.baIdor.com/products/generators/idlc.asp) EOZZ 0ENERATORS O a) E 0 0) U 0 ri ti CD CO "4 - CD 6) E Z 6) 0 6) t6 t6 0 m E .0 to 0 t0 L 0) 0 U Standard Features, HPE Level 2 • Sound Attenuated Enclosure • Noise reduction 25dBA at 3 Meters • Unit Mounted Radiator suitable for 40°C Ambient • External mount Hospital Grade silencer. Silencer is mounted above the enclosure roof using heavy duty powder coated brackets. Integral rain shield is included on exhaust pipe to enclosure opening to divert rain and debris away from the genset area. • Air Intake Hoods Tined with acoustic foam are mounted over Fixed Acoustic Louvers for Cooling Air Intake. Hoods are manufactured of aluminum and the louvers are made of mil finished aluminum exterior with fiberglass insulation and perforated aluminum on interior facing surface. Louvers divert rain and debris away from the genset area and include a bird and debris screen. • Air Discharge Hood is mounted in front of the unit mounted radiator and includes an integral Punched Screen Barrier to protect from birds and falling debris. Discharge Hood is lined with acoustic foam insulation and includes a rain gutter to channel water away from the genet interior. Discharge hood and barrier is made of the same enclosure material to complement the genset exterior. • Sound Deadening Interior Surface is designed with a barium sulfate reflector sandwiched between two sections of 1-1/2 inches of thermoset fiber material. The 3+ inches of acoustic insulation is set between the exterior wall and a perforated mil finished aluminum interior wall. 1111111111111111111111. _,„„,"„,_ 3 liilIiP Ilnormrt *.�,ata5mora 41111111111 19i See Data Sheet for dimension information. (httpJ/www.baldor.com/products/generators/idic.asp) Noise Attenuation Methods Sound Attenuation Material Specifications • Inorganic glass fiber bonded with thermosetting resin into pre -formed 1-1/2 inch thick boards. Minimum density is 3.0 Ib/ft3 (48 kg/cm3). • Surface burning meet NFPA 90A and 90B • Corrosive resistance meet ASTM C665 and exceeds Mil -I -24244B for stress corrosion • Moisture absorption is less than 5% by weight when exposed to air at 120°F (49°C) and 95% humidity for 96 hours per ASTM C553 • Shrinkage is less than 0.3% linear per ASTM C356 • Interior wall is made of 0.032 inch thick perforated mil finish aluminum with a minimum of 40% open area for maximum sound absorption • Level 2 enclosures include a Barium Sulfate Loaded Vinyl Sheet Reflector sandwiched between two layers of 1-1/2 inch glass fiber boards. Reflector is 1 Ib/ft2 surface mass and meet ASTM E 90-90. Level 1 Noise Attenuation Enclosure - vat. tom;_? Interior Surface Outside Wall v " \..-- r Perforated Aluminum Insulation Insulation Level 2 Noise Attenuation Enclosure try MCA + Interior Surface Outside Wall S%o:? ._, Perforated Aluminum Barium Sulfate "ter a ra Insulation `, GS 2g - Insulation EA.T -DOIR GENERATORS