HomeMy WebLinkAbout53-81 RESOLUTION1
a
RESOLUTION NO.
A RESOLUTION AUTHORIZING THE MAYOR AND CITY CLERK
TO EXECUTE AN AGREEMENT WITH SOUTHWESTERN ELECTRIC
POWER COMPANY FOR AN UNDERGROUND ELECTRIC DISTRIBUTION
SYSTEM TO THE BALL FIELDS AT LAKE FAYETTEVILLE PARK.
BE IT RESOLVED BY THE BOARD OF DIRECTORS OF THE CITY OF
FAYETTEVILLE, ARKANSAS:
That the Mayor and City Clerk are hereby authorized
and directed to execute an agreement with Southwestern Electric
Power Company for an underground electric distribution system
to the ball diamonds at Lake Fayetteville Park. A copy of
the agreement authorized for execution hereby is attached
hereto marked Exhibit "A" and made a part hereof.
CrZit '
747 .'..‘404Tra4P
r L41dir craictarf ritl
, .4 du3S 914Att
,.r.
!,..1 C174qERK
74Pgral-'--t-:,:pt
"wli<Z1
PASSED AND APPROVED this
day of 9Tain , 1981.
APPROVED:
CERTIFICATE OF RECORD
State of Arlcansas
(
City of Fayette%-ille ( SS
I, Vivian ICoettel, City clerl
recorder fond Ex -Officio
for the City of Fayetteville. cio here-
by certit3r that the annexed or
of record iis
my n office and foregoingtie pears in 02.db:1:ice Ce same
Resoltztion book
–IC
it page 342 -
hand and sea) this, easys-':fIY
1 9 -Gel__ .
. City oet-a-ecctetr--4—ind tyrder
MiCROFILMED
"-•
SOUTHWESTERN ELECTRIC POWER COMPANY
AGREEMENT FOR UNDERGROUND ELECTRIC DISTRIBUTION SYSTEM
FOR COMMERCIAL AND/OR INDUSTRIAL CUSTOMERS
BETWEEN CITY OF FAYETTEV/LLE
(Customer - Developer)
AND
SOUTHWESTERN ELECTRIC POWER COMPANY
It is mutually understood and agreed that:
I. This agreement applies to installation and operation of an underground electric
distribution system to serve commercial and/or industrial customers on an electric
utility easement granted Southwestern Electric Power Company (SWEPCO) on Lake
Fayetteville Road, East of Rwy 71 North in Fayetteville, Ark. and is further
identified by SWEPCO Drawing No.law811i57 which is Made a part of this agreement.
II. Electric service covered by this agreement shall be: (Indicate One)
( ) A. For individual customer served by a three phase pad mount transformer or
equivalent.
(X) B. For individual customer served by a single phase pad mount transformee.-or4
equivalent.
( ) C. For a loop primary system serving one or more individual custOra‘"re froe. . :4 -'1.‘
1:;Tht...A1 41. -NV -A
multiple three phase pad mount transformers or equivalent.
A
( ) D. For several customers served from a single three phaselpad-maint“,transformerr<i
or equivalent.
e
AW?;
III. Service Voltage will be: (Indicate One)
( ) A. 208Y/120 volts, three phase 4 wire. "
( ) B. 480Y/277 volts, three phase 4 wire.
(R) C. 120/240 volts, single phase, 3 wire(Availeble for II B type of service only.)
IV. Under this agreement customer will furnish:
A. Concrete pad for transformer in accordance with SWEPCO Standard.
B. Concrete pads for any switching equipment required in loop system as outlinedin II C.
C. Conduit from SWEPCO pole to transformer location. Conduit size will be 4" in case
• of three phase service and 2" for the single phase. This may be rigid galvanized,
concrete encased duct, or Schedule 40 rigid plastic as required by local codes.
For faster restoration of service in case of cable failure a spare conduit is
recommended but not required except those cases where conduit is under a building.
Customer elects to:
09 1. Install one conduit only.
( ) 2. Install two conduits one being a spare.
D. Service connection cables between transformer and service entrance equipment.
Cables will be of sufficient length to be terminated on transformer bushings.
(Connections will be made by SWEPCO.)
E . Any necessary pullboxes or manholes occasioned by routing or by length.
F. Pay the installed cost of primary cable in excess of 250 feet of conduit run.
V. SWEPCO will furnish and install:
A. All primary cable and necessary material for connection to overhead system.
B . Transformers
C. Switch enclosures
D . Any overhead distribution required to provide this service.
E . Terthination of secondary cables.
(continued on reverse side)
•
•
•
VI. Any rearrangements in the system which may be required by the customer after installation
and any temporary work required by the customer shall be paid for by the customer.
VII. Should customer, owner and/or developer abandon the use of this underground electric
distribution system prior to fulfillment of contract period, he agrees to pay to the
Company an amount of money equal to the depreciated value of the system installed,
plus the removal cost, less credit for salvage material or equipment.
WITNESS:
WITNESS:
(SIGNED) LARRY 1. PHILLIPS, JR,
ATTACHMENT: Drawing No. pm81•57
Work Order No. ,437
SWEPCO
UED-C/I
031574
ACCEPTED 5-19-81 DATE
CITY 07 FAYETTEVILLE
BY
llAYOR
(Customer)
(Official Capacity)
ACCEPTED JUN22 lt7)81 DATE
SOUTHWESTERN ELECTRIC POWER COMPANY
BY
/1%.*,:c (.1
President
NOTE: CUSTOMER TO PAY INST)-7D4LECOST OF
PRILV1ARYs CABLE IN EXCESS OF 250'
OF CONOur Roy .
Jf
•
•P4
CMBLE NEEDEP
8 ./9 C. /.../ 44 / N UM /5 KV
NO. LENGTHS
LE MOTH
A
i
135'
/00
..- !C./0ER
lAik ED •All {Lir EP,
F\
FIELD 3
KW46
CUSTOMER TO FURNISH AND INSTALL
7 RANSFORMER PAD PER SieliFFCC DS -
SillePCO TO FUR:Nis7-i AND INST,z
100 KVA. 7200 120/ 24-0vc. T A/1
TRANSFORMER , SDR- ,
100
C.U5TOMCR To AliSA pi:D /iv .cr
2 ":_scHetnA iJvC. 7
pc() TO FORNI MVP
, ISIKV CI-18LE
'740.445 ter To
C,95L& IN EXCESS
FIELD I,
FEED EXISTING.
NOTE: EXISTJMG 03
PRIMARY FUSED
AT ISA.
snenvcr 1, it a- A C SR 7. rE' -------
t 1 RCSR NEUT-CAL
tONDUCTC--R (100') •
4•11M.
L.7/LI
?
48 A
Pkaa--
461R --
Ac)
NcSi
CODE
10-R
5 F -30A
1
F AY E7 TEVI LI E PR KlieVS/95
SCHOOL DI STR /CT frk /
REV
:INSTAit.(...4 DE
RA K -I00, .R.E443 YE: GUY- teL,
GUY -Wit ANE-/. 971) •
---N
1
fl
5 35; LiC - 127
Fmk- ‘_•Y--- 12/, 011K- KY,
/:? AIC -'-, G - 1, ocit wr -1/53,
(FUSE 30 Pi (20 "ice),
14-, RE K- /00,
1.
sfc
DATE
SUBJECT
70 INSTALL 7.2 kV OVEREETIO UNDER-
0ROUNP. 1:49C/ciii65 7-0 SERVS:
.NE141 BALI. FIEZ05 eAkie 1.-MiaTTEV1114
AREA , HIGHWAY 7/ N. IN ,
FAYE.TTE-Vie.:.LEJ ARK 14 itjs,95
SOUTHWESTERN ELECTRIC POWER CO.
ENGINEERING
FAYETTEVILLE
DEPARTMENT
DIVISION
APPROVED 17421"-"--•-mcNI---C ENGR IN CHARGE
42SLIQO
APPROV se; e
DIV 114,1PT.
APPROVED Gra ENG
NOTE: INSTRLL 50 AMP
FUSE, ON Jci IN Y. OFF3�
FEEDER - ST/ A
TOIAC MY ,y, 11,47
DATE: 4 -/S-SV
SCALE: '
•
WORK
ORDER
DRWIL
NO 0
Es2.40