Loading...
HomeMy WebLinkAbout2009-03-23 - Agendas - Final a a ARKANSAS 113 W.Mountain St. Fayetteville,AR 72701 Telephone:(479)575-9267 AGENDA FOR A MEETING OF THE PLANNING COMMISSION Monday,March 23,2009,5:30 p.m. Room 219,City Administration Building ORDER OF PLANNING COMMISSION MEETING A. Introduction of agenda item—Chair B. Presentation of Staff Report C. Presentation of request—Applicant D. Public Comment E. Questions&Answer with Commission F. Action of Planning Commission(Discussion&Vote) NOTE TO MEMBERS OF THE AUDIENCE If you wish to address the Planning Commission on an agenda item please queue behind the podium when the Chair asks for public comment. Public comment occurs after the Planning Staff has presented the application and will only be permitted during this part of the hearing for each item. Members of the public are permitted a maximum of 10 minutes to speak;representatives of a neighborhood group will be allowed 20 minutes. The applicant/representative of an application before the Planning Commission for consideration will be permitted a maximum of 20 minutes for presentation. Once the Chair recognizes you,go to the podium at the front of the room and give your name and address. Address your comments to the Chair, who is the presiding officer. He/She will direct them to the appropriate appointed official, staff member or others for response. Open dialogue will not be permitted: please ask any questions, and answers will be provided once public comment has been closed. Please keep ,your comments brief,to the point,and relevant to the agenda item being considered so that everyone has a chance to speak. , Please, as a matter of courtesy, refrain from applauding or booing any speakers or actions of the Planning Commission. 2009 Planning Commissioners Sean Trumbo Lois Bryant Matthew Cabe James Graves Porter Winston Andy Lack Christine Myres Jeremy Kennedy Jill Anthes A17ayve eville TENTATIVE AGENDA ARKANSAS The City of Fayetteville,Arkansas 113 W.Mountain St. Fayetteville,AR 72701 Telephone:(479)575-8267 AGENDA FOR A MEETING OF THE PLANNING COMMISSION Monday,March 23,2009,5:30 p.m. Room 219,City Administration Building The following items will be considered: Consent Aeenda: 1.Approval of the minutes from the Monday,March 9,2009 meeting. 2. ADM 09-3238: (KANTZ CENTER/STARBUCKS CCP EXTENSION): Submitted by CRAFTON TULL SPARKS for property located at the NW CORNER OF CROSSOVER RD AND CITIZENS DR. The property is zoned C-1, NEIGHBORHOOD COMMERCIAL and contains approximately 14.85 acres. The request is for a one year extension for the approval of the Concurrent Plat 08-2905. Planner: Jesse Fulcher New Business: 3. RZN 09-3233: Rezoning (PHYSICIAN'S SPECIALTY HOSPITAL, 175): Submitted by CEI ENGINEERING ASSOCIATES, INC. for property located at 3873 NORTH PARKVIEW DRIVE. The property is zoned R-Q RESIDENTIAL OFFICE and contains approximately 2.97 acres. The request is to rezone the subject property to P-1, Institutional Planner:Dara Sanders 4. ADM 09- 3250: (RUSKIN HEIGHTS SIDEWALK AND CURB FINISH VARIANCE): Submitted by Ruskin Heights, LLC for the Ruskin Heights R-PZD located on the south side of Mission Boulevard, west of Crossover Road. The request is for a variance of the minimum street design standards to permit a smooth, exposed aggregate finish for the curb, gutter, and sidewalk, when the standards require a broom finish. Planner:Andrew Garner 5. Informational item: Election of Planning Commission Officers. All interested parties may appear and be heard at the public hearings. A copy of the proposed amendments and other pertinent data are open and available for inspection in the office of City Planning(575-8267), 125 West Mountain Street,Fayetteville,Arkansas. All interested parties are invited to review the petitions. Interpreters or TDD for hearing impaired are available for all public hearings;72 hour notice is required. For further information or to request an interpreter,please call 575-8330. PC Meeting of March 23, 2009 ARKANSAS THE CITY OF FAYETTEVILLE, ARKANSAS 125W. Mountain St. Fayetteville,AR 72701 PLANNING DIVISION CORRESPONDENCE Telephone:(479)575-8267 TO: Fayetteville Planning Commission FROM: Jesse Fulcher, Current Planner THRU: Jeremy Pate, Director of Current Planning DATE: March 16, 2009 ADM 09-3238: (KANTZ CENTER/STARBUCKS CCP EXTENSION): Submitted by CRAFTON TULL SPARKS for property located at the NW CORNER OF CROSSOVER RD AND CITIZENS DR. The property is zoned C-1, NEIGHBORHOOD COMMERCIAL and contains approximately 14.85 acres. The request is for a one year extension for the approval of the CCP 08- 2905. Planner: Jesse Fulcher BACKGROUND Property Description and History: On February 25,2008,the Planning Commission approved CCP 08-2905 (Kantz Center/Starbucks), for a 3-lot commercial subdivision at the northwest corner of Crossover Road and Citizens Drive, Proposal: The applicant requests to extend the approval of the Concurrent Plat for one year from the original date of approval, to expire on February 25, 2010. The Planning Department received the applicant's extension request on February 26,2009,within the required 18 month time limit. Should this extension be granted, all permits and approvals required by City, State,and Federal regulations to start construction of the development are required to be issued before the one-year extended deadline. If the permits are not issued prior to February 25, 2010, all of the approved plans for the project shall be rendered null and void, or the applicant may apply for a final one-year extension. RECOMMENDATION Planning Staff recommends approval of ADM 09-3238,the requested extension to CCP 08-2905, with the following conditions: 1. The applicant shall be allowed until February 25, 2010 to receive all permits necessary to complete construction of the project. If all permits have not been received by this time,the Preliminary Plat approval shall be revoked;the applicant does have the ability to apply for one additional extnsion within that time frame. 2. All other conditions of approval for the project shall remain applicable. K:IReports120091PC Reports109-March 23WDM 09-3238(Kana Center_Starhucks CCP extension).doc March 23,2009 Planning Commission ADM 09-3238 Kanti Center CCP Ext. Agenda Item 2 Page 1 of 8 DISCUSSION The City of Fayetteville Unified Development Code(UDC)Section 166.20(B)(2)gives the Planning Commission authority to extend approval of a planned zoning district development one additional year within 18 months of the original approval. In order to extend this approval,the applicant must: (1) request the extension prior to the one year time limit, and (2) show good cause why the tasks could not reasonably be completed within the normal one year. If the one year extension is granted, it is within this time that the applicant shall receive all permits and approvals as required by City, State, and Federal regulations to start construction of the development or project. (1) The applicant has submitted the extension request to the Planning Division on February 26, 2009,prior to the 18 month time limit ending on August 25, 2009. (2) The applicant has stated that the condition of the economy and market have delayed Starbuck's construction schedule, which has delayed this project, and additional time is needed before the project can be started. K.IReporiA2009NC Reports109-March 23WDM09-3238(Kantr Center_Starbucks CCP extenston).doc March 23,2009 Planning Commission ADM 09-3238 Kantz Center CCP Ext. Agenda Item 2 - Page 2 of 8 g � -� QPCMeeting ARKANSAS THE CITY OF FAYETTEVILLE, ARKANSAS 125 W. Mountain St. Fayetteville,AR 72701 PLANNING DIVISION CORRESPONDENCE Telephone:(479)575-8267 TO: Fayetteville Planning Commission FROM: Jesse Fulcher, Current Planner Matt Casey, Assistant City Engineer THRU: Jeremy Pate, Director of Current Planning DATE: n 49 Updated March 7, 2008 CCP 08-2905: Concurrent Plat (KANTZ CENTER/STARBUCKS,371): Submitted by CRAFTON TULL SPARKS for property located at the NW CORNER OF CROSSOVER RD. AND CITIZENS DR. The property is zoned C-1,NEIGHBORHOOD COMMERCIAL and contains approximately 14.85 acres. The request is to divide the subject property into three tracts of 13.08, 1.03, and 0.74 acres. Planner: Jesse Fulcher Findings: Property Description and Background: The subject property contains 14.85 acres, located between Mission Boulevard (Hwy 45) and Crossover Road (Hwy 265), and is zoned C-1, Neighborhood Commercial. The site consists of the Kantz Shopping Center and an undeveloped tract at the northwest corner of Citizens Drive and Crossover Road, which was approved for development of a Starbucks Coffee shop and retail building by the Planning Commission on September 24, 2007. Table 1 Surrounding Land Use and Zoning Direction Land Use Zoning from Site North Office/Residential R-0 South Bank C-1 East Bank/Crossover Road ROW C-1/R-O West Mixed commercial C-1 Proposal: The applicant requests concurrent plat (preliminary and final plat) approval for a commercial subdivision with three commercial lots containing 13.08 (Tract 1), 1.03 (Tract 2), and 0.74 (Tract 3) acres. Infrastructure, easements, right-of-way, street improvements, etc. were determined at the time of development of Kantz Center and with approval of the Large Scale Development for Starbucks development(LSD 07-2676). K.IRepores120081PC Reports104-February 251CCP 08-2905(Kantz Center_Starbucks).doc March 23,2009 Planning Commission ADM 09-3238 Kantz Center CCP Ext Agenda Item 2 Page 3 of 8 Right-of-way being dedicated: Sufficient right-of-way exists for Crossover Road, Mission Boulevard and Citizens Drive. Street Improvements: Street improvements have been evaluated as part of the approved large scale development on the property. Adjacent Master Street Plan Streets: Mission Blvd., Principal Arterial; Crossover Rd., Principal Arterial; Citizens Dr., Local Street Parkland Dedication: Parkland dedication is not applicable for this commercial subdivision. Tree Preservation: Tree preservation was determined with the previously approved large scale development. Recommendation: Staff recommends approval of CCP 08-2905 with the following conditions: Conditions of Approval: 1. Subdivision Committee determination of a waiver request to allow the subdivision of property without extending public water service to Tract 2. Staff recommends in favor of the waiver request. Water service shall be extended to Tract 2 at the time of development. 2/14/08: THE SUBDIVISION COMMITTEE FOUND,IN FAVOR OF THE REQUESTED WAIVER. 2/25/08: THE PLANNING COMMISSION FOUND: IN FAVOR OF THE REQUESTED WAIVER. 2. Subdivision Committee determination of a waiver from Chapter 177.04 (D) (Perimeter Landscaping Requirement). All parking lots shall have five feet (5') of landscaped area between the property line and parking lot. Staff recommends in favor of the requested waiver,finding that the circumstance requiring the waiver is due to the need for cross- access to the north, which the applicant is providing with the approved large scale development. This will allow for better utilization of the shared drive aisles and _ "connectivity between the adjacent properties. This waiver shall only be applicable with the approved large scale development. 2/14/08: THE SUBDIVISION COMMITTEE FOUND IN FAVOR OF THE REQUESTED WAIVER. 2/25/08: THE PLANNING COMMISSION FOUND IN FAVOR OF THE REQUESTED WAIVER. 3. All applicable conditions of approval of the original LSD 06-2676 shall remain in place. 4. The applicant shall make the final revisions prior to recordation: K.IReports120081PC Reports104-February 251CCP O8-2905(Kantz Center Stmbucb).doc March 23,2009 Planning Commission. ADM 09-3238 Kantz Center CCP Ext Agenda Item 2 Page 4 of 8 a. Change the title of the Landscape Administrator to Urban Forester. b. Replace the surveyor's signature block with City approved language. Standard Conditions of Approval: 5. Plat Review and Subdivision comments (to include written staff comments provided to the applicant or his representative, and all comments from utility representatives - AR Western Gas, SWBT, Ozarks, SWEPCO, Cox Communications). 6. All street names and addresses shall be approved by the 911 Coordinator. 7. Submit a digital copy of the approved final plat on CD to the Planning Division prior to recordation of final plat. 8. Staff approval of final detailed plans, specifications and calculations (where applicable) for grading, drainage, water, sewer, fire protection, streets (public and private), sidewalks, parking lot(s) and tree preservation. The information submitted for the plat review process was reviewed for general concept only. All public improvements are subject to additional review and approval. All improvements shall comply with City's current requirements.r 9. All overhead electric lines 12kv and under shall be relocated underground. All proposed_ utilities shall be located underground. 10. Impact fees for water, sewer, police and fire shall be paid in accordance with:City ordinance. Planning Commission Action: Approved ❑ Forwarded ❑ Tabled Meeting Date: February 25,2008 Motion: Ostner Second: Winston Vote: 5-0-0 (consent) Comments: The "Conditions of Approval" listed in the report above are accepted in total without exception by the entity requesting approval of this development item. Signature Date K.IReports120081PC Reports109-February 251CCP 08-2905(Kuntz Center_Starbuckr).doc - March 23,2009 Planning Commission ADM 09-3238 Kantz Center CCP Ext. Agenda Item 2 Page 5 of 8 -:J— YAW Grarit 11hI k W February 25,2009 Grafton Tull Sparks archiledure I eagineerq favvep Mr. Jesse Fulcher City of Fayetteville 113 W. Mountain Street Fayetteville AR,72701 RE: Extension,of Concurrent Plat Kantz Center Starbuck's Dear Mr. Fulcher, On behalf of our client,Kathy Ball,we would like to request a one year extension of the approved Concurrent Plat mentioned above. Conditions in the economy and market have caused the project to be delayed on Starbuck's construction schedule which has caused a delay for the entire project. We apologize for any inconvenience this may have caused the City of Fayetteville and we appreciate your willingness to review this request. If you have any further questions or concerns please do not hesitate to caltme,:. Sincerely, lonathan Ely,E.I., LEER APO Civil Engineer March 23,2009 Planning Commission ADM 09-3238 Kantz Center CCP Ext. Agenda Item 2 Page 6 of 8 ADM09-3238 KANTZ CENTER CCP EXTENSION Close Up View i 1 ? SUBJECT PROPERTY i t �t y tix�u x r� s d mix x z � z xx S Y 0.2'^. 3ts.����zf�ei���'�'�:x�x'e x�� x ix�+*,'.`�, �'��y^x✓'x �ry YlA I I N e y ISSION eLVD MISSION BLVD 1t x - �� Overview l9 ea •- 94— 0 75 150 300 450 600 M irch 23,2009 Feet PI nning Commission ADM 09-3238 Kantz Center CCP Ext. gena em Page 7 of 8 ADM09-3238 KANTZ CENTER CCP EXTENSION One Mile View SKILLERN RD o I w & �OODSRDOK x O ,D � Y Yt UP t 2, < t` d P`7Y o h r f^ J l i RSFi n , yQy4 �A�eb$10 � , PV R � ✓ �., 1f�0p\4Y ��F��tSFd\ 1. r+,y� 01 '�`�s`\i"„�z➢ �Y�ai c, , A RSF yt_� 1s�5,. k�\�ye- .\ �d� ��, m S l TP SrY '' SF"{„f[!• ARBF l V YU Vv,4 YVAK`O t Y � ; m st�C1y.� 1 r�gFras-,(t5f'd R2 Yr:`sr"sv°?{+sF4^v�rrtFa.�2s�N SUB.IECT PROPERTY '�1vl �P ,AV\A' tY a . f�xry �"t `" nhrsr v.v�BDSDEA'rtdut ems..�.,`�Y FtSFd r ' C0. Sf t RSFA' RENT;LN? t x\ L t '�... tRard,E RSF-0 l RSFd m ASFd � f CYM`110`Ar YRS �\v �G• �O RSFd4 k > Zf is 1' > `t Y \ A S\� � HUNTER Rn Uv K \A\ Z rxsFt RSFA RS-0 xl ti Y � sRsrs� iY nTsra[v o 4EC rxs AF s x`'I .p m Y � i ' la f #� tic,fi,Ytr\ L i .t�' th } 1 �.y,\E LIP � I I.. A>•YN�u'�`�', � t; ;„ a 1 n Y,x{�A 3n�5e A'•N$ w. A � Y Y ,1i Y� U�fil RSFA\, 4���� V O" Y � O li,. , h0RSU v\\� � ��Nv,i Fi a Al,� •, 11 150 . v�, k\ax Yv.,1P ,� "vFl� w 1� �,JY vo , u� ti 11 tY - u t R 1�` MANDR DR i(>MANORDR � � �t���'♦,1� 1 <\VYsvu,'�\ \`,Awls+ `�Utiv Overview Legend Boundary -"---, Subject Property Planning Area ❑ ADM09-3238 0 000Y� 0000°Overlay District Outside City Legend Hillside-Hilltop O erlay District 0 0.25 0.5 1 arch 23,2009 M arch Commission t Agenda Item 2 - Page 8 of 8 g ..a" F q u '> u s 3 = PC Meetingof March 23 2009 1 F ARKANSAS THE CITY OF FAYETTEVILLE,ARKANSAS 125 Mountain Fayetteevv Mountain AR 72701 PLANNING DIVISION CORRESPONDENCE Telephone:(479)575-8267 TO: Fayetteville Planning Commission FROM: Dara Sanders, Current Planner Matt Casey, Assistant City Engineer THRU: Jeremy Pate, Director of Current Planning DATE: March 17, 2009 RZN 09-3233: (PHYSICIAN'S SPECIALTY HOSPITAL, 175): Submitted by CEI ENGINEERING ASSOCIATES,INC.for property located at 3873 NORTH PARKVIEW DRIVE. The property is zoned R-O, RESIDENTIAL OFFICE and contains approximately 2.97 acres. The request is to rezone the subject property to P-1, Institutional. Planner: Data Sanders BACKGROUND: Property Description: The subject property is located on North Parkview Drive, north of Joyce, Boulevard and south of the Park Apartments,a multiple-family development.The 2.96-acre tract is currently developed for the Physician's Surgery Center with one medical office/hospital building and associated parking. History:In 1991,the Planning Commission approved a development request to construct a medical office building on the subject property,a permitted use in the R-O,Residential Office zoning district. In 2007,the applicant submitted a large scale development application to the Planning Division for an expansion of the existing office building. Staff determined that the proposed use of the property had shifted from a medical office to an out-patient surgery operation, which would require a conditional use permit to operate a hospital (Use Unit 4) in the R-O zoning district. The Planning Commission approved the applicant's Large Scale Development request (LSD 07-2536) to add a 20,506-foot addition to the structure and Conditional Use requests for off-site parking (CUP 07 2540)and to operate a hospital use in the R-O zoning district(CUP 07-2539).In 2008,the Planning Commission approved a new Conditional Use request to allow for a 3`d floor addition to the structure,finding that an expansion of the hospital use on the subject property is compatible with the surrounding area.Any expansion or change of use would require a new conditional use permit under the current R-O zoning. SURROUNDING LAND USE AND ZONING: Direction from Site Land Use Zoning North I Multi-family apartment complex RMF-24 South,East, and West I Professional office R-O K:IReports120091PC Reports109-March 231RZN 09-3233(Physician's Specialty Hospital).doc March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 1 of 14 Proposal: The applicant proposes to rezone the property from R-O, Residential Office to P-1, Institutional so that the underlying zoning district will accurately reflect the use and development of the property that was approved previously by the Planning Commission. Public Comment: Staff has not received public comment. RECOMMENDATION: Staff recommends forwarding the rezoning request RZN 09-3233(Physician's Surgery Center)to the City Council with a recommendation of approval based on findings stated herein. PLTNINC COIIYIIS�ON SCTt)1 Recluued __._._ Date 1�arcl �3,2'OI19 II Tal>iled ...., d hoarded Q-�}e oon. Second s ate �. CITY COUNCIL AfqAjON—25 Resllit urea :. BA: ppro� d 43-2eatr@d Date INFRASTRUCTURE: Streets: The site has access to Parkview Drive. This is a fully developed two lane city street. Water: Public water is available to the property. There is a 4"main along Parkview Drive. Sewer: Sanitary sewer is available to the site. There is an 8" public main along the west property line of this parcel. Drainage: Standard.improvements and requirements for drainage will be required.for the development. This property is affected by the 100-year floodplain. Police: It is the opinion of the Fayetteville Police Department that this RZN will not substantially alter the population density, and will not create an appreciable or undesirable increase in the load on police services. This RZN will not create an appreciable increase in traffic danger and congestion. CITY PLAN 2025 FUTURE LAND USE PLAN: City Plan 2025 Future Land Use Plan designates this site as Residential Neighborhood Area, which recognizes conventional subdivision development but encourages traditional neighborhood development that incorporates low-intensity non-residential uses. K.Rep orts12009LPC Rep ortr109-March 231RZN 09-3233(Physician's Specialty Hospital0.doc March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 2 of 14 FINDINGS OF THE STAFF 1. A determination of the degree to which the proposed zoning is consistent with land use planning objectives,principles, and policies and with land use and zoning plans. Finding: The proposed P-1 zoning is consistent with the City's Residential Neighborhood Area land use designation to encourage traditional neighborhood development that incorporates non-residential uses. Based on the City's adopted land use planning objectives and principles, staff finds that the subject property, along Joyce Boulevard, in close proximity to an Urban Center Area, surrounded by other existing and approved health care and professional office uses,and relatively dense residential development, would be more appropriately regulated under the P-1 zoning district than the current Residential Office(R-O)zoning designation. In 2007 and 2008, the Planning Commission found that the hospital use at this location was compatible with the adjacent properties and the surrounding neighborhoods.Staff has not received any complaints regarding the hospital use,or any indication of land use compatibility issues.Staff finds that the request to rezone to P-1,Institutional is an appropriate designation for the current use and for future development on the property. 2. A determination of whether the proposed zoning is justified and/or needed at the time the rezoning-is proposed. Finding: The Physician's Specialty Hospital provides a medical service not only to the citizens of Fayetteville but to the entire region. This specialized medical service provides same-day medically necessary and elective surgery procedures that do not require extended hospital stay or supervision. Staff finds that the Hospital provides + . increased access to health care for the residents of Northwest Arkansas.Staff finds that the proposed zoning is justified and needed to allow for the facility to adapt or continue serving persons with medical needs in a growing community. While the Physician's Specialty Hospital has already obtained conditional use approval from the Planning Commission to operate a hospital (Use Unit 4) on the subject property,staff finds that the rezoning request is justified to avoid the delay . and expense of having to obtain a new conditional use permit for any future expansion. Staff recommends in favor of the rezoning request, finding that rezoning the property to P-1,Institutional,which allows city-wide uses(Use Unit 1),cultural and recreational facilities(Use Unit 4),and government facilities(Use Unit 5)would be compatible with surrounding land uses and zoning. Staff also finds that the P-1 zoning district would more accurately reflect and govern the existing use and development of the property than the current R-O zoning.Future development on the site under P-1 would continue to be compatible under the City's standard development regulations.Additionally,the bulk and area requirements of the R-O and the P-1 zoning districts have similar setback requirements and maximum K.IReports120091PCReports109-March 23WZN 09-3233(Physician'v Specialty Hospital).doc March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item Page 3 of 14 building area percentages; therefore, staff finds that the intensity and density allowed on the subject property will not substantially change as a result of the rezoning request. 3. A determination as to whether the proposed zoning would create or appreciably increase traffic danger and congestion. Finding: It is expected that a rezoning from R-O to P-1 would result in the potential for a slight increase in traffic compared with that allowed under the existing zoning. However, during review of the previously approved conditional use request, staff and the Planning Commission found that the hospital use as proposed by the applicant,would not create a noticeable increase in traffic to the property or result in a dangerous traffic condition.This site is accessed off of an improved local street (Parkview Drive)connecting directly to an improved Principal Arterial street,Joyce Boulevard.The existing street infrastructure is capable of supporting the volumes of traffic that could be generated under the P-1 zoning. 4: . A determination as to whether the proposed zoning would alter the population density and thereby undesirably increase the load on public services including schools, water, and sewer facilities. Finding: Staff finds that the proposed zoning would not create undesirable impacts to public' services,or a density that is incompatible with the surrounding area, based on a review of infrastructure, existing land uses, and the development potential of=the property.The property is currently being utilized for a medical office and hospital facility. The change in zoning to P-1 would not permit uses that would adversely impact public services. Increased load on public services were taken into consideration and recommendations from the Engineering,Fire,and Police Departments are included in this report. 5. If there are reasons why the proposed zoning should not be approved in view of considerations under b (1) through (4) above, a determination as to whether the proposed zoning is justified and/or necessitated by peculiar circumstances such as: a. It would be impractical to use the land for any of the uses permitted under its existing zoning classifications; b. There are extenuating circumstances which justify the rezoning even though there are reasons under b (1)through(4)above why the proposed zoning is not desirable. Finding: Not applicable. Staff recommends in favor of the requested zoning. K.IReports120091PCReportsl09-March 23IRZN09-3233(Physician's Specialty Hospital).doc March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 4 of 14 Fayetteville Unified Development Code (3) Land area per dwelling unit. 161.16 District R-O,Residential Office Manufactured home 3,000 sq.ft. Townhouses&apartments: (A) Purpose. The Residential-Office District is No bedroom. 1,000 sq.ft. designed primarily to provide area for offices One bedroom 1,000 sq.ft. without limitation to the nature or size of the Two or more bedrooms 00 s .ft. Fraternityor Sorority 5050 0 sq.ft.per resident office, together with community facilities, restaurants and compatible residential uses. (D) Density. (B) Uses. Units er acre 1 24 or less (1) Permitted uses. (E) Setback regulations. Unit 1 City-wide uses by right Front 15 ft. Unit 5 Government facilities Front,if parking is allowed between the right 5o ft. Unit 8 Single-family dwellings of-way and the building Unit 9 Two-family dwellings Front,in the Hillside Overlay District 15 ft. Unit 12 Offices,studios and related services Side 10 ft. Unit 25 Professional offices Side,when contiguous to a residential district 15 ft. - - - - - Side,in the Hillside Overlay District 8 ft (2) Conditional uses. Rear,without easement or alley 25 ft. Rear,from center line of public alley loft Rear,in the Hillside Overlay.District 15 ft. Unit 2 City-wide uses b conditional use permit ' Unit 3 Public protection and utility facilities Unit 4 Cultural and recreational facilities (F) Building height regulations.' - Unit'l1 Manufactured home park Unit 13 Eating laces Buildin-Height Maximum Unit 15 Neighborhood shopping oods 'Unit 24 Home occupations - Unit 26 Multi-family dwellings Height regulations. Any building which Unit 36 Wireless communications facilities exceeds the height of 20 feet shall be setback from Unit a2 Clean technolo ies .any side boundary line of an adjacent single family district an additional distance of one foot for each (C) Bulk and area regulations. foot of height in excess of 20 feet. (Per dwelling unit for residential structures) (G) Building area. On any lot,the area occupied (1) Lot width minimum. by all buildings shall not exceed 60%of the total area of such lot. Manufactured home park 100 ft. Lot within a manufactured home 50 ft. (Code No.1965,App.A.,ArL 5(x);Ord.No.2414,2-7-78;Ord.No. ark .2603,2-19-80;Ord.No.2621,4-1-80;Ord_No.1747;6-29-70;Code , Single-family 60 fL 1991,§160.041;Ord.No.4100,§2(Ex.A),6-16-98;Ord No.4178, Two-family 60 ft. 8-31-99;Ord.4726,7-19-05;Ord.4943,11-07-06;Ord.5079,11-20- Three or more 90 ft. 07;Ord.5195, 11-6-08;Ord.5224,3-3-09) (2) Lot area minimum. Manufactured home ark 3 acres Lot within a manufactured home 4,200 sq.ft. ark Townhouses: Development 10,000 sq.ft. Individual lot 2,500 sq.ft. Single-family 6,000 sq.ft. Two-family 6,500 sq.ft. Three or more8,000 s .ft. Fraterni or Sorority1 acre K:tReportsl20091PCReports109-March23IRZN09-3233(Physician's Specialty Bospital).doc March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 5 of 14 Fayetteville Unified Development Code 161.26 District P-1,Institutional (A) Purpose. The Institutional District is designed to protect and facilitate use of property owned by larger public institutions and church related organizations. (13) Uses. (1) Permitted uses. C -wide uses by right I Unit :::�C'ultml and recreational facilities I Units 1 Government facilities (2) Conditional uses. Unit 2 City-wide uses by conditional use permit Unit 3 Public protection and utili facilities Unit 26 Multi-family dwellings Unit f 36 Wireless communications facilities Unit42 Clean technologies (C) Density. None. (D) Bulk and area regulations. None. Setback regulations. Front 30 ft. Front,if parking is allowed between the right-of- 50 ft. way and the building Side 20 ft. Side,when contiguous to a residential district 25 ft. Rear 25 ft. Rear,from center line of public alley 10 ft. (F) Height regulations. There shall be no maximum height limits in P-1 Districts,provided,, however, that any building which exceeds the height of 20 feet shall be set back from any boundary line of any residential district a distance of one foot for each foot of height in excess of 20 feet. (G) Building area On any lot the area occupied by all buildings shall not exceed 60%of the total area of such lot. (Code 1965,App.A.,Art.5(XI);Ord.No.2603;Ord.No.2603,2-19- 80;Ord. No. 2621,4-1-80; Ord.No. 1747, 6-29-70; Code 1991, §160.042;Ord.No.4100,§2(Ex.A),6-16-98;Ord.No.4178,8-31- 99;Ord.5073,11-06-07;Ord.5195, 11-6-08) K.Wep oru 12 0 0 9W C Rep o ris 1 0 9-March 2 3 U?ZN 09-3233(Phys ic ian's Specialty Horp i1a 1).do c March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 6 of 14 ENGINEERING DIVISION COMMENTS RZN 09-3233: (PHYSICIAN'S SPECIALTY HOSPITAL, 175): Submitted by CEI ENGINEERING ASSOCIATES, INC. for property located at 3873 NORTH PARKVIEW DRIVE. The property is zoned R-O, RESIDENTIAL OFFICE and contains approximately 2.97 acres. The request is to rezone the subject property to P-1, Institutional. Planner: Dara Sanders Public water is available to the property. There is an 8"main along Parkview Drive. Sanitary sewer is available to the site. There is an 8" public main along the west property line of this parcel. The site has access to Parkview Drive. This is a fully developed two lane city street. Standard improvements and requirements for drainage will be required for any development. This property is not affected by the 100-year floodplain. March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 7 of 14 Date 2/25/09 Jeremy Pate Zoning and Development Director City of Fayetteville 113 W. Mountain Fayetteville, Arkansas 72701 Dear Director Pate, This document is in response to the request for a determination of whether the proposed RZN 09-3233: (Physician's Specialty Hospital, 175): Submitted by CEI Engineering Associates, Inc., for property located at 3873 N. Parkview Drive would substantially alter the population density and thereby undesirably increase the load on public services and create an appreciable increase in traffic danger and congestion. The property contains approximately 2.97 acres. It is the opinion of the Fayetteville Police Department that this RZN will not substantially alter the population density, and will not create an appreciable or undesirable increase in the load on police services. This RZN will not create an appreciable increase in traffic danger and congestion. Sincerely, Captain William Brown Fayetteville Police Department March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 8 of 14 Andrew Garner Re comments for planning items due 2/20 Fire. Deaa�ent Cor ments From: David Williams To: Lintvedt, Karl; Sanders, Dara Date: 3/18/09 8:46AM Subject: Re: comments for planning items (due 2/20) Dara, I have not had a chance to review this yet. I do not feel it will effect any of the department's services by changing to P-1. Thanks, David Williams Fire Marshal Fayetteville Fire Dept. email: dwilliams@ci.fayetteville.ar.us >>> Dara Sanders 3/13/2009>>> David, Have you had a chance to look at this request? I will be out of the office all of next week. Please forward your comments to one of the other planners on Monday if you can't send them today. Thanks! Dara Sanders Planning Division City of Fayetteville >> Karl Lintvedt 2/25/2009 10:40 AM >>> Police, Fire, and Engineering: The following item from today's Technical Plat Review agenda requires comments from your department regarding potential impacts on City services. I've attached a map to give you an idea of the project's location and scale. Please return the comments by Friday, March 6, and feel free to contact me with any questions you might have. As always, we appreciate your help. RZN 09-3233: (PHYSICIAN'S SPECIALTY HOSPITAL, 175): Submitted by CEI ENGINEERING ASSOCIATES, INC. for property located at 3873 NORTH PARKVIEW DRIVE. The property is zoned R-O, RESIDENTIAL OFFICE and contains approximately 2.97 acres. The request is to rezone the subject property to P-1, Institutional. Planner: Dara Sanders Thanks, Karl Lintvedt Planning Technician City of Fayetteville 479-718-7688 CC: Fulcher, Jesse; Garner, Andrew March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 9 of 14 - Consolidated Land Development Services 3317 SW"I"Street * Bentonville,AR 72712 • (479) 273-9472 • Fax (479) 273-0844 February 23, 2009 City of Fayetteville 125 W. Mountain St. Fayetteville, AR 72701 (479) 575-8267 RE: Rezone —Written Description Physicians Specialty Hospital CEI Project #23586.0 1 On behalf of Physicians Surgery Center, CEI Engineering Associates, Inc. is requesting a rezoning of the property indicated on the attached rezone application and per the attached legal description. Rezoning is requested from an R-O zoning district to a P-1 zoning district. Rezoning of the afore mentioned property is requested to provide a better zoning for the current use of the property and to clean up conditional uses on the property. Land use for the proposed zoning will remain the same as well as traffic and appearance as what is currently approved. Thank you for your consideration on this matter and please do not hesitate to contact us with questions or comments. Respectfully submitted, Jae Ineman, RLA Pr j r ect Manager March 23,2009 Planning Commission CALIFORNIA • ARIZONA • TEXAS • ARKANSAS • MINNESOTA • PEN NSYLVAN IAV-Wl`GFGKFGFAysi(ft0MNIiiaIty Hosp. Agenda Item 3 Page 10 of 14 Consolidated Land Development Services 3317 SW"I"Street * Bentonville,AR 72712 • (479) 273-9472 • Fax (479) 273-0844 February 23, 2009 City of Fayetteville 125 W. Mountain St. Fayetteville, AR 72701 (479) 575-8267 RE: Rezone —Written Statements Physicians Specialty Hospital CEI Project#23586.0 A rezone from the current R-0 zoning district to a P-1 zoning district is consistent with the current use of the property and rezoning to this district would effectively clean up the conditional use permits approved for the site. Under current usage the rezone should not increase the amount of traffic generated. Under current usage there should not be an increase on public utilities or infrastructure due to the rezone. Thank you for your consideration on this matter and please do not hesitate to contact us with questions or comments. Rjeec ully submitted, Ja e eman, RLA P ject Manager March 23,2009 Planning Commission CALIFORNIA • ARIZONA • TEXAS • ARKANSAS • MINNESOTA • PEN NSYLVANIAFZZPGEGKGFAly6iftommKialty Hosp. Agenda Item 3 Page 11 of 14 RZN09-3233 PHYSICIAN'S SPECIALTY HOSPITAL Close Up View L � I Ia a x 0 SUBJECT PROPERTY Ia Ia ' � 2 PARKSNORE OR PARKDHORE DR I - I I 2 ��,yvy Ask: r r ID DVD D C B D O C BLVD O d�y�. l TCE DLVD. L -?t �,•;. b�t axe,%) Y }\, Overview 777 e_ 0 75 150 300 450 600 Marc 23,2009 Feet Plann ng Commission RZN 9-3233 Physician's Specialty Hosp. Page 12 of 14 RZN09-3233 PHYSICIAN'S SPECIALTY HOSPITAL One Mile View 0 AIN IND 9 +N `I i r m � n la c vF4,itY �, H P x '•1'•. �--� V�a%'.'$b t— SUBJECTPROPERTY Holt R r v �1 SF{�. ;11 <1 EIgtNEAOEJ NRq` �v '+�RSFd 7110RNHILL dR� � d�r�s. tr C7 +'g4tt`° V5Nd13DN 3I \. V 9 4 t - I Haadun xi t 4� Overview Legend Boundary _ - Subject Property i'`�,planning Area E ®RZN09-3233 - o Overlay Distract 000°°o Outside City Legend Hillside-Hilltop O erlay District 0 0.25 0.5 1 2009 23Wommission Agenda Item 3 Page 13 of 14 March 23,2009 Planning Commission RZN 09-3233 Physician's Specialty Hosp. Agenda Item 3 Page 14 of 14 TZI PC Meeting of March 23, 2009 ARKANSAS 125 W. Mountain St. THE CITY OF FAYETTEVILLE, ARKANSAS Fayetteville,AR 72701 Telephone:(479)575-8267 PLANNING DIVISION CORRESPONDENCE TO: Fayetteville Planning Commission FROM: Andrew Garner, Senior Planner THRU: Jeremy Pate, Director of Current Planning DATE: March 18, 2009 ADM 09-3250(Ruskin Heights Sidewalk and Curb Finish Variance,370).Submitted by Ruskin Heights,LLC for the Ruskin Heights R-PZD located on the south side of Mission Boulevard,west of Crossover Road. The request is for a variance of the minimum street design standards to permit a smooth, exposed aggregate finish for the curb, gutter, and sidewalk, when the standards require a broom finish. Planner: Andrew Garner Findings: Background:The Ruskin Heights R-PZD 06-2299 is located on the south side of Mission Boulevard, west of Crossover Road. This project was approved by the Fayetteville City Council on March 20, 2007.The developer is in the process of developing the first phase of the project and has constructed much of the infrastructure required for final plat. Proposal: The applicant is requesting a variance of the City's requirements for a broom finish for curb, gutter, and sidewalk construction.The applicant proposes to pressure wash the surface of the concrete instead of a broom finish,to create a smooth,exposed aggregate finish for the curb,gutter, and sidewalk. The applicant's letter states that the proposed finish will have a more traditional appearance. Discussion: The curb and gutter for the entire development has already been constructed with the proposed finish.Early on during the construction,the contractor and the developer were notified by the Engineering Division that the finish did not meet the City's criteria and they were instructed not to continue.The developer continued this construction method against the instructions of City staff. Staff has concerns with the proposed finish because the layer of cement on top of the concrete has been removed by the pressure washing. Staff's opinion is that this top layer of cement provides protection for the concrete from natural elements,and with that layer being removed the life of the concrete is severely shortened.Additionally,a pressure washed finish on the sidewalk will result in a smoother sidewalk that is less safe for pedestrians than a broom finished sidewalk that provides better traction. A memo from the City Engineering Division is attached and describes the issues in detail. K.IREPORM0091PCREPORYY09-MARCH23WDM09-3250(RUSKINHGHTSCURBSWVARIANCE).DOC March 23,2009 Planning Commission ADM 09-3250 Ruskin Heights Agenda Item 4 Page 1 of 10 Staff has the following recommendations for ADM 09-3250 (Ruskin Heights Curb and Sidewalk Variance): Curb and Gutter Recommendation: Staff recommends approval the variance to permit a pressure washed finish on the curb and gutter with the following condition: 1. Planning Commission determination of a variance from Fayetteville Unified Development Code Section 171.01(A) to permit a pressure washed finish on curb and gutter,as opposed to a broom finish.Staffrecommends in favor of this variance with the condition that a 20 year maintenance bond for the replacement value of the curb and gutter be provided prior to final plat recordation. Sidewalk Recommendation: Staff recommends denial of the variance to permit a pressure washed finish on public sidewalks: 2. Planning Commission determination of a variance from the Fayetteville Unified Development Code Section 171.13(A)(16)to permit a pressure washed finish on public sidewalk,as opposed to a broom finish.Staffrecommends denial, because the proposed finish is considerably smoother than the standard broom finish. With the steepness ofthe development, changing the texture ofthe pedestrian sidewalk to a smoother finish could increase the likelihood ofslips andfalls. PLANNING COMMISSION ACTION: yes Required Approved Denied Date: March 23,2009 Comments: The "CONDITIONS OF APPROVAL", stated in this report, are accepted in total without exception by the entity requesting approval of this development item. BY Title Date K:IREPOR7S120091PCREPOR73109-MARCH231ADM09-3250(RUS19NHGHTSCURBSWVARIANCE).D0C March 23,2009 Planning Commission ADM 09-3250 Ruskin Heights Agenda Item 4 Page 2 of 10 FAYETTEVILLE THE CITY OF FAYETTEVILLE,ARKANSAS 113 W. Mountain St. Fayetteville,AR 72701 Telephone:479-575-8206 ENGINEERING DIVISION CORRESPONDENCE TO: Planning Commission Members FROM: Matt Casey P.E., Assistant City Engineer DATE: March 17, 2009 SUBJECT: Ruskin Heights Concrete Finish Waiver Request Ruskin Heights LLC,the developer of Ruskin Heights,has submitted a letter to the City requesting a waiver of the City's requirements for curb and gutter and sidewalk construction. The developer is requesting to pressure wash the surface of the concrete to create a smooth,exposed aggregate finish for both the curb and gutter and the sidewalk. The curb and gutter for the entire development has already been constructed with the proposed finish. Early on during the construction, the contractor and the developer were notified by the Engineering Division that the finish did not meet the City's criteria and they were instructed not to continue. The developer continued this construction method against the instructions by the City staff. On August 6, 1996, the Fayetteville City Council passed a resolution(#94-96) adopting the current version of the Minimum Street Standards. In these standards, Section 4-6 states that all curb and gutter shall be Portland Cement concrete meeting the requirements of Arkansas Highway and Transportation Division standard specifications. Section 802.19 of the AHTD specs calls for either a broomed finish or a rubbed finish for the construction of curb and gutter. A rubbed finish is seldom used in this area. The finish that is generally used and widely accepted is the broomed finish_ With this finish, after the concrete has been placed and smooth, a coarse broom is rubbed across the concrete to roughen the fine layer of cement that coats the concrete. This finish provides a texture to the concrete that has sufficient traction for both pedestrians and vehicular traffic. The concern that the Engineering staff has with the proposed finish is that the layer of cement on top of the concrete has been removed. It is our opinion that this layer provides protection for the concrete from natural elements such as rain,snow,and temperature extremes. It is true that over the coarse of many years this layer is gradually worn away an no longer offers protection. At that point, the concrete becomes more susceptible to wear and deterioration. With that layer being removed at the beginning of construction, we feel that the life of this concrete has been severely shortened. Engineering staff recommends that the curb and gutter either be removed and replaced with proper Ruskin Heights Page 1 of 2 March 23,2009 Planning Commission ADM 09-3250 Ruskin Heights Agenda Item 4 Page 3 of 10 construction methods,or a maintenance bond be submitted with the City for the replacement value of the curb for a term of 20-years. The developer is also requesting that a waiver be granted allowing this same pressure washed, exposed aggregate finish to be used for all of the public sidewalks in the development. Section 171.13(A)(16)of the City of Fayetteville Unified Development Code states that the material used for sidewalk construction shall be Portland Cement Concrete having a broom finish. In addition, the AHTD specifications also call for a broom finish for sidewalk construction. In addition to the concerns stated for the curb and gutter,the traction issue for the sidewalks is critical. The proposed finish is considerably smoother than the standard broom finish. With the steepness of the development,changing the texture of the pedestrian sidewalk to a smoother finish could increase the likelihood of slips and falls. In chapter 4 of the United States Department of Transportation sponsored publication, "Designing Sidewalks and Trails for Access," it states "A broom finish should be used on concrete sidewalks to increase the slip resistance for pedestrians. Decorative paints and surfaces,such as polished stones or exposed aggregate rock,are not as slip resistant and should be avoided." For these reasons, the Engineering Division recommends that this waiver request not be approved and that the sidewalks be constructed with a broom finish. Ruskin Heights Page 2 of 2 March 23,2009 Planning Commission ADM 09-3250 Ruskin Heights Agenda Item 4 Page 4 of 10