Loading...
HomeMy WebLinkAbout2001-07-09 - Agendas - Final AGENDA FOR A REGULAR MEETING OF THE PLANNING COMMISSION A meeting of the Fayetteville Planning Commission will be held Monday,July 9,2001 at 5:30 p.m. in the City Administration Building, 113 West Mountain Street,Room 219, Fayetteville,Arkansas. The following items will be considered: Approval of minutes from the June 25,2001 meeting. New Business: 1. LSD O1-21.00: Large Scale Development(Merit Electric, pp 642)was submitted by Milholland Company on behalf of Merit Electric for property located south of Pump Station Road and east of City Lake Road. The property is zoned I-1 and I-2, Heavy Commercial/Light Industrial and General Industrial and contains approximately 2 acres. The request is to build an 8,460 sq.ft. warehouse. 2. LSD 01-19.00: Large Scale Development (Hometown Developments, pp 524) was submitted by Robert Schmitt of Hometown Developments for property located on the south and west corner of Fletcher Avenue&Rodgers Drive. The property is zoned R-2, Medium Density Residential and contains approximately 0.50 acres with 7 dwelling units proposed. 3. ADM O1-28.00: Administrative Item (Hometown Development, pp 524) was submitted by Robert Schmitt on behalf of Hometown Development for property located south and west of the intersection of Fletcher&Rodgers Avenue. The request is for a waiver of the City of Fayetteville minimum street standards. 4. CUP O1-19.00: Conditional Use(City of Fayetteville P.V.F.V, pp 600)was submitted by Jamie Highfill on behalf of the City of Fayetteville for property located at 1932 S. Garland. The property is zoned I-1 and R-1, Heavy Commercial/Light Industrial and Low Density Residential and contains approximately 5.15 acres. The request is to allow parking in a R-1 district. 5. RZN O1-10.00: Rezoning (McDonald,pp 329)was submitted by George Faucette on behalf of James & Judy McDonald for property located at 461 E. Township. The property is zoned R-1,Low Density Residential and contains approximately 0.42 acres. The request is to rezone to C-2, Thoroughfare Commercial 6. ANX 01-2.00: Annexation (Cross Creek Subdivision,LLC,pp 359) was submitted by Philip Humbard of Engineering Services Inc.on behalf of Cross Creek Subdivision, LLC for property located east of Sunshine Road and south of Mount Comfort Road. The property is in the Planning Growth Area and contains approximately 14.47 acres. 7. RZN O1-11.00: Rezoning(Cross Creek Subdivision,LLC,pp 359)was submitted by Philip Humbard of Engineering Services Inc. on behalf of Cross Creek Subdivision, LLC for property located east of Sunshine Road and south of Mount Comfort Road. The property is zoned A-1, Agricultural and contains approximately 14.47 acres. The request is to rezone to R-1,Low Density Residential. 8. RZN O1-12.00: Rezoning(Reindl, pp 484) was submitted by Robert Sharp, Architect on behalf of Brian Reindl for property located at 509 W. Spring Street. The property is zoned I-1, Heavy Commercial/Light Industrial and contains approximately 1.91 acres. The request is to rezone to C-3, Central Commercial. All interested parties may appear and be heard at the public hearings. A copy of the proposed amendments and other pertinent data are open and available for inspection in the Office of City Planning(575-8264),City Administration Building, 113 West Mountain Street,Fayetteville,Arkansas. All interested parties are invited to review the petitions. Interpreters or TDD for hearing impaired are available for all public meetings. 72 hour notice ,is required. For further information or to request an interpreter,please call Don Bunn at 575-8330. ORDER OF PLANNING COMMISSION MEETING A. Introduction of agenda item- Chairman B. Presentation of request-Applicant C. Public Comment D. Response by Applicant/Questions & Answer with Commission E. Action of Planning Commission(Discussion and vote) NOTE TO MEMBERS OF THE AUDIENCE If you wish to address the Planning Commission on an agenda item,raise your hand when the Chairman asks for public comment. He will do this after he has given Planning Commission members the opportunity to speak and before a final vote is taken. Public comment will only be permitted during this part of the hearing for each item. Once the Chairman recognizes you, go to the podium at the front of the room and give your name and address. Address your comments to the Chairman, who is the presiding officer. He will direct them to the appropriate appointed official, staff member or others for response. Please keep your comments brief,to the point, and relevant to the agenda item being considered so that everyone has a chance to speak. Please, as a matter of courtesy,refrain from applauding or booing any speakers or actions of the Planning Commission. 2001 Planning Commissioners: Bob Estes - Chairman Lorel Hoffman -Vice Chairman Lee Ward- Secretary Nancy Allen Don Bunch Sharon Hoover Don Marr Loren Shackelford Alice Bishop Addendum to Planning Commission Agenda Packet for July 9,2001 Replace 2.2 with 2.2a LSD 01-19.00 Page 2 4. All replacement trees shall be a minimum 2 inch caliper. The required replacement shall include 8 large trees which will require a total of 3200 square feet of growing space (open land not in utility easements, rights-of-way, or the like)to ensure proper growing space. 5. Approval of this project by the Planning Commission does not guarantee that sewer capacity will be available at the time of construction. 6. Plat Review and Subdivision comments (to include written staff comments provided to the applicant or his representative, and all comments from utility representatives-AR Western Gas, SWBT, Ozarks, SWEPCO, Cox Communications) 7. Staff approval of final detailed plans, specifications and calculations (where applicable) for grading, drainage,water, sewer, fire protection, streets (public and private), sidewalks, parking lot(s) and tree preservation. The information submitted for the plat review process was reviewed for general concept only. All public improvements are subject to additional review and approval. All improvements shall comply with City's current requirements. 8. Sidewalk construction in accordance with current standards to include a minimum six foot sidewalk with a minimum six foot greenspace 9. Large Scale Development approval to be valid for one calendar year. 10. Prior to the issuance of a building permit the following is required: a. Grading and drainage permits b. Separate easement plat for this project c. Project Disk with all final revisions d. Completion of all required improvements or the placement of a surety with the City (letter of credit, bond, escrow) as required by §158.01 "Guarantees in Lieu of Installed Improvements"to guarantee all incomplete improvements. Further, all improvements necessary to serve the site and protect public safety must be completed, not just guaranteed,prior to the issuance of a Certificate of Occupancy. Background: An Administrative Item was approved by the Planning Commission on April 23, 2001 to allow this project to proceed without the proper street frontage. This approval was conditioned upon approval of a Large Scale Development and limited to six units per lot. The proposed Large Scale Development was reviewed at the May 30, 2001 Technical Plat review and was tabled at the June 14, 2001 Subdivision Committee meeting due to several corrections that were requested to be added to the plan. The project was presented to the Subdivision Committee again on June 28, 2001. Discussion at the Subdivision Committee meeting included the proposed site density,tree preservation, traffic, and sewer capacity. The Subdivision Committee forwarded the Large Scale Development to the full Planning Commission Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.2a AGENDA FOR A REGULAR MEETING OF THE PLANNING COMMISSION A meeting of the Fayetteville Planning Commission will be held Monday,July 9,2001 at 5:30 p.m. in the City Administration Building, 113 West Mountain Street,Room 219, Fayetteville,Arkansas. The following items will be considered: Approval of minutes from the June 25,2001 meeting. New Business: 1. LSD O1-21.00: Large Scale Development(Merit Electric, pp 642)was submitted by Milholland Company on behalf of Merit Electric for property located south of Pump Station Road and east of City Lake Road. The property is zoned I-1 and I-2, Heavy Commercial/Light Industrial and General Industrial and contains approximately 2 acres. The request is to build an 8,460 sq.ft. warehouse. 2. LSD 01-19.00: Large Scale Development (Hometown Developments, pp 524) was submitted by Robert Schmitt of Hometown Developments for property located on the south and west corner of Fletcher Avenue&Rodgers Drive. The property is zoned R-2, Medium Density Residential and contains approximately 0.50 acres with 7 dwelling units proposed. 3. ADM O1-28.00: Administrative Item (Hometown Development, pp 524) was submitted by Robert Schmitt on behalf of Hometown Development for property located south and west of the intersection of Fletcher&Rodgers Avenue. The request is for a waiver of the City of Fayetteville minimum street standards. 4. CUP O1-19.00: Conditional Use(City of Fayetteville P.V.F.V, pp 600)was submitted by Jamie Highfill on behalf of the City of Fayetteville for property located at 1932 S. Garland. The property is zoned I-1 and R-1, Heavy Commercial/Light Industrial and Low Density Residential and contains approximately 5.15 acres. The request is to allow parking in a R-1 district. 5. RZN O1-10.00: Rezoning (McDonald,pp 329)was submitted by George Faucette on behalf of James & Judy McDonald for property located at 461 E. Township. The property is zoned R-1,Low Density Residential and contains approximately 0.42 acres. The request is to rezone to C-2, Thoroughfare Commercial 6. ANX 01-2.00: Annexation (Cross Creek Subdivision,LLC,pp 359) was submitted by Philip Humbard of Engineering Services Inc.on behalf of Cross Creek Subdivision, LLC for property located east of Sunshine Road and south of Mount Comfort Road. The property is in the Planning Growth Area and contains approximately 14.47 acres. 7. RZN O1-11.00: Rezoning(Cross Creek Subdivision,LLC,pp 359)was submitted by Philip Humbard of Engineering Services Inc. on behalf of Cross Creek Subdivision, LLC for property located east of Sunshine Road and south of Mount Comfort Road. The property is zoned A-1, Agricultural and contains approximately 14.47 acres. The request is to rezone to R-1,Low Density Residential. 8. RZN O1-12.00: Rezoning(Reindl, pp 484) was submitted by Robert Sharp, Architect on behalf of Brian Reindl for property located at 509 W. Spring Street. The property is zoned I-1, Heavy Commercial/Light Industrial and contains approximately 1.91 acres. The request is to rezone to C-3, Central Commercial. All interested parties may appear and be heard at the public hearings. A copy of the proposed amendments and other pertinent data are open and available for inspection in the Office of City Planning(575-8264),City Administration Building, 113 West Mountain Street,Fayetteville,Arkansas. All interested parties are invited to review the petitions. Interpreters or TDD for hearing impaired are available for all public meetings. 72 hour notice ,is required. For further information or to request an interpreter,please call Don Bunn at 575-8330. LSD 01-21.00 Page I PC Meeting of July 9.2001 FAYETTEVILLE THE CITY OF FAYETTEVILLE,ARKANSAS Merit Electric,LSD 113 W. Mountain St. Fayetteville,AR 72701 TO: Fayetteville Planning Commission Members THRU: Tim Conklin, City Planner FROM: Sara Edwards,Ron Petrie P.E. DATE: July 5,2001 Project: LSD 01-21.00: Large Scale Development(Merit Electric, pp 642) was submitted by Milholland Company on behalf of Merit Electric for property located south of Pump Station Road and east of City Lake Road. The property is zoned I-1 and I-2,Heavy Commercial/Light Industrial and General Industrial and contains approximately 2 acres. The request is to build an 8,460 sq.ft. warehouse. Findings: The subject property is located approximately 500 feet southeast of the intersection of City Lake Road and Pump Station Road.Adjacent property is zoned A-I to the north and east and I-1/I-2 to the south. City Lake Road is a collector street on the Master Street Plan and has the required right-of-way existing. The applicant is providing the 15 parking spaces required by ordinance. Currently 22.4%of the site is covered in tree canopy. The applicant is proposing to preserve 5.5% of the site and to replace 10.3%canopy. The total preserved and replaced is 15.8%. The requirement in an I-1 zone is 15%. The Tree and Landscape Administrator is in support of this replacement due to the poor health of the trees on this site. Recommendation: Approval subject to the conditions listed below. Conditions of Approval: 1. Planning Commission determination of the requested waiver from §172.01(C)(3)which requires that a one-way parking lot aisle be 12 feet wide. The applicant is requesting to provide a 27'aisle in order to facilitate the movement of large truck traffic. Please see attached request from applicant. Staff is in support of this request. 2. Planning Commission determination of the requested waiver from §172.01(F)(2)(a) which requires that"all landscaped islands be protected from potential damage by vehicles by placing concrete curbs or wheel barriers adjacent to the landscaped area." The applicant is proposing to curb the area around the landscaping between the two curb cuts. However, they are not proposing to area on the outside of the driveways. Please see attached request from applicant. Staff is not in support of this request and is recommending that both sides of the driveways be curbed in order to protect all required Planning Commission July 9, 2001 LSD01-21 Merit Electric Page 1.1 LSD 01-21.00 Page 2 landscaping. 3. Plat Review and Subdivision comments (to include written staff comments provided to the applicant or his representative, and all comments from utility representatives- AR Western Gas, SWBT, Ozarks, SWEPCO, Cox Communications) 4. Staff approval of final detailed plans, specifications and calculations(where applicable) for grading, drainage, water, sewer, fire protection, streets (public and private), sidewalks, parking lot(s) and tree preservation. The information submitted for the plat review process was reviewed for general concept only. All public improvements are subject to additional review and approval. All improvements shall comply with City's current requirements. 5. Sidewalk construction in accordance with current standards to include a minimum six foot sidewalk with a minimum ten foot greenspace. 6. Large Scale Development approval to be valid for one calendar year. 7. Approval of this project does not guarantee that sewer capacity will be available at the time of construction. 8. Prior to the issuance of a building permit the following is required: a. Grading and drainage permits b. Separate easement plat for this project c. Project Disk with all final revisions d. Completion of all required improvements or the placement of a surety with the City (letter of credit,bond, escrow) as required by §158.01 "Guarantees in Lieu of Installed Improvements"to guarantee all incomplete improvements. Further, all improvements necessary to serve the site and protect public safety must be completed,not just guaranteed,prior to the issuance of a Certificate of Occupancy. Background: The proposed Large Scale Development was reviewed at the June 13, 2001 Technical Plat review and the June 28, 2001 Subdivision Committee meeting. Discussion at the Subdivision Committee meeting included tree preservation and the parking lot waiver requests. The Subdivision Committee forwarded the Large Scale Development to the full Planning Commission subject to all staff comments. INFRASTRUCTURE: Planning Commission July 9, 2001 LSD01-21 Merit Electric Page 1.2 LSD 01-21.00 Page 3 a) Water. Existing b) Sanitary sewer. Existing. C) Streets. Existing. d) Grading and Drainage. A preliminary grading plan and drainage report has been submitted. A final plan and report will be required prior to beginning construction. APPLICABLE CODE SECTIONS: §172.01 OFF-STREET PARKING LOT DESIGN REQUIREMENTS. C. Parking lot design standards. 3. TABLE 1. DIMENSIONAL REQUIREMENTS: Angle Type Width Curb I Way 2 Way Stall (A) (B) Length Aisle Aisle Depth (In (C) Width Width (E) Feet) (In (D) (D) (In Feet) (In (In Feet) Feet) Feet) 00 Standard 8 22.5 12 24 8 Parallel Compact 7.5 19.5 12 24 7.5 300 Standard 9 18 12 24 17 Compact 7.5 15 12 24 14 450 Standard 9 12.5 12 24 19 Compact 7.5 10.5 12 24 16 600 Standard 9 10.5 18 24 20 Compact 7.5 8.5 15 24 16.5 900 Standard 9 9 24 24 19 Compact 7.5 7.5 22 24 15 Planning Commission July 9, 2001 LSD01-21 Merit Electric Page 1.3 LSD 01-21.00 Page 4 §172.01 OFF-STREET PARKING LOT DESIGN REQUIREMENTS. F. Parking Lot Landscaping Requirements. 2. General Requirements: a. Separation of Landscaped Areas and Vehicles.All landscaped areas shall be protected from potential damage by vehicles by placing concrete curbs or wheel barriers adjacent to the landscaped area except as provided in §17.2.b. b. Vehicle Overhang.Except when exercising Option 3., F.3.a.(3)., a portion of a standard parking space may be landscaped instead of paved to meet part of the landscaping requirement. The landscaped area may be up to two feet of the front of the space as measured from a line parallel to the direction of the bumper of the vehicle using the space. Landscaping may only be ground cover plants in the overhang area PLANNING COMMISSION ACTION: -yes-Required Approved Denied Date: Comments: CITY COUNCIL ACTION: Required Approved Denied Date: The "CONDITIONS OF APPROVAL", beginning on page one of this report, are accepted in total without exception by the entity requesting approval of this development item. by title date Planning Commission July 9, 2001 LSDOI-21 Merit Electric Page 1.4 l d AoCCand Company REGISTRATIONS: eng.i.neering. &Sa vecyinq PE:AR, OK, MO Melvin L. Milholland, PE, PLS PLS: AR, OK June 19, 2001 Project No. E-595 City of Fayetteville 113 W. Mountain St. REfolmi'v" Fayetteville, AR 72701 JUN ? 0 2001 ATTN: Sara Edwards, Planning P ALINING DIV. RE: Merit Electric-Waiver requests Dear Sara: The following Waivers are requested for the above referenced project in accordance with comments received from PLAT REVIEW-In-House Review Committee. 1. 172.0l.F.2.A.2.b. Landscaping shall be dispersed throughout the parking area and located within concrete curbed islands sis inches high. CURBS WILL HAMPER THE CONSTRICTED VEHICULAR CIRCULATION PATTERN AND IS NOT NEEDED FOR DRAINAGE CONTROL IN THIS INDUSTRIAL SETTING. 2. 166.08.6.Table page 26. Collector Streets between curb cuts= 30' - TO ALLOW TWO "CURB CUTS"ALONG CITY LAKE ROAD A DISTANCE OF 29'HAS BEEN PROVIDED FOR LARGE DELIVERY TRUCK(TRACTOR-TRAILER) TURNING RADIUS 3. 172.0l.c.3. One Way Aisle Width with Parallel Parking= 12' -DUE TO LARGE DELIVERY TRUCKS AND THE LOADING/UNLOADING OF THESE TRUCKS, A WIDE DRIVE IS NEEDED AROUND THE BUILDING. THIS AREA CONTAINS ONLY TOW PARKING SPACES;ALL OTHER SPACES ARE LOCATED ON THE FRONT SIDE OF THE BUILDING. Reasons for requests: 1. Curb and guttering would hamper the constricted vehicular circulation pattern, and is not needed for drainage control at this rural industrial site setting. 2. Curbing, along the north of hard surfaced asphalt areas, in combination with a low retaining wall is used to direct increased surface flow from adjoining properties. Planning Commission 105 West Center Street; Fayetteville,Arkansas 71701; Phone: (501)443-4714; fax: (501) July 9, 2001 LSD01-21 Merit Electric Page 1.5 /n�d�/ilkoCCand Company REGISTRATIONS: L�nQineerin�. C7�urvet�en� PE: AR, OK, MO Melvin L. Milholland, PE, PLS PLS: AR, OK 3. Two parallel parking spaces are provided for employee parking on the north side of the building inside security fencing. This location is for warehouse employees and when making delivers after hours their car may be in a protected area. 4. By designating an entrance and exist, and restricted traffic circulation to south bound vehicular movement, double"curb cuts" are necessary to accommodate service to this site. The distance between the requested "curb cuts"is 29-feet. Sincerely, Mil and C pa Thomas M. Jefcoat, ASLA Project Manager cc: Gary W.Rakes E:\E-595\docs\01.06.19-WaiverRequest.wpd Planning Commission 205 West Center Street; Fayetteville,Arkansas 72701; Phone: (501)443-4724; Fax: (501) July 9,2001 LSD01-21 Merit Electric Page 1.6 0 City of Fayetteville Tree Preservation Application & Plan Requirements Applicant Name: Gary Rakes Date: 05-24-01 Project Name: Merit Electric Plat Page k 642 Location: City Lake Road Zoning: I-1 & I-2 ZONING: % MIN. CANOPY R-1 Low Density Residential 25% R-1.5 Moderate Density Residential 20% R-2 Medium Density Residential 20% R-3 High Density Residential 20% _ R-0 Office and Professional 20% C-1 Neighborhood Commercial 20% C-2 Thoroughfare Commercial 15% % Tree Canopy _ C-3 Central Business 15% Required to be Preserved*: 15 % _ C4 Downtown Commercial 10% X 1-1 Light IndustriaVHeavy Commercial 15% Total Area of Site: X I-2 Heavy Industrial 15% Acres: 2.00 _ P-1 Institutional 25% Square Feet: 87,080.79 Total Area of Existing Tree Canopy: Acres: 0.45 Square Feet: 19,543 % of Total Site Area: 22.4% Existing Tree Canopy Preserved: Acres: 0.11 Square Feet: 4,790 " % of Total Site Area' 5.5% Replacement Tree Canopy: Must have previous approval by Landscape Administrator Acres: 0.21 Square Feet: 9,000 % of Total Site Area: 10.3% Total Canopy: (Preserved Tree Canopy+Replacement Canopy as approved) Acres: 0.32 Square Feet: 13,790 % of Total Site Area: 15.8% The fee for Tree Preservation is$120.00 and can be paid at the Planning Office in the City Administration. For further clarification, see the attached step by step process for tree preservation plans, or contact the Landscape Administrator at 575-8308. Planning Commission July 9, 2001 LSD01-21 Merit Electric Page 1.7 LSD01 -21 AERIT ELECTROCLOSE UP Q t �o -1 E�:] A-1 a Subject Property j 1-2 -1 El d Master Street Plan Freeway/Expressway N N Principal Arterial Minor Arterial w E Collector Historical Collector s STREETS 200 0 200 400 600 800 Feet Planning Commission July 9, 2001 LSD01-21 Merit Electric Page 1.8 LSD 01 -21 OERIT ELECTRIC ONE MILE _ R�2 R-1 � 19TH 1-1 1-2 Subject Property R-1 1-1 h 1-2 Z co p 2 1-2 G Q R-1 yk Master Street Plan , Freeway/Expressway N Principal Arterial .• Minor Arterial Collector w E Historical Collector S v STREETS .". ; Fayetteville City Limits 0.5 ' 0 0.5 Mlles Planning Commission NEI July 9, 2001 LSD01-21 Merit Electric Page 1.9 Planning Commission July 9, 2001 LSDOI-21 Merit Electric Page 1.10 LSD 01-19.00 Page 1 PC Meeting of July 9, 2001 FAYETTEVILLE THE CITY OF FAYETTEVILLE,ARKANSAS Hometown Development,LSD 113 W. Mountain St. Fayetteville,AR 72701 TO: Fayetteville Planning Commission Members THRU: Tim Conklin, City Planner FROM: Sara Edwards,Ron Petrie P.E. DATE: July 5,2001 Project: LSD 01-19.00: Large Scale Development (Hometown Developments, pp 524) was submitted by Robert Schmitt of Hometown Developments for property located on the southwest corner of Fletcher Avenue & Rodgers Drive. The property is zoned R-2, Medium Density Residential and contains approximately 0.50 acres with seven dwelling units proposed. Findings: This property was before the Planning Commission on April 23, 2001 with a request to not provide the required street frontage for lots in an R-2 zone. Right-of-way for Center Street exists directly in front of this property and runs parallel with Fletcher Street. This waiver was approved subject to the project being processed as a large scale development. The applicant is proposing to provide seven units with four bedrooms each. There is property zoned R-2 to the east, west and south of this project. If this project is not approved, the applicant is requesting to build Center Street which would require several waivers to be approved by the Planning Commission(AD 01-28). Recommendation: Staff recommends denial of the proposed large scale development that has seven units proposed. Staff would support the project if it is limited to six units as conditioned by the Planning Commission action AD 01-11.00. Conditions of Approval: 1. The applicant shall remove the seventh unit and the associated parking to be in compliance with the Administrative Item (ADO1-11) conditions of approval that allowed this development to proceed without street frontage. See the attached conditions of approval and minutes from the Planning Commission approval ofAD 01-11. 2. Planning Commission determination of offsite improvements to Fletcher Avenue. A recent traffic count has determined that 834 vehicles per day presently use Fletcher Avenue. This development is projected to add 94 vehicles per day. The staff recommendation is that the portion of Fletcher Avenue adjacent to the Center Street Frontage be widened to 14'from centerline with curb &gutter. 3. All Dumpsters and utility equipment shall be screened. Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.1 LSD 01-19.00 Page 2 4. All replacement trees shall be a minimum 2 inch caliper. 5. Approval of this project by the Planning Commission does not guarantee that sewer capacity will be available at the time of construction. 6. Plat Review and Subdivision comments (to include written staff comments provided to the applicant or his representative, and all comments from utility representatives-AR Western Gas, SWBT, Ozarks, SWEPCO, Cox Communications) 7. Staff approval of final detailed plans, specifications and calculations(where applicable) for grading,drainage, water, sewer, fire protection, streets (public and private), sidewalks, parking lot(s) and tree preservation. The information submitted for the plat review process was reviewed for general concept only. All public improvements are subject to additional review and approval. All improvements shall comply with City's current requirements. 8. Sidewalk construction in accordance with current standards to include a minimum six foot sidewalk with a minimum six foot greenspace 9. Large Scale Development approval to be valid for one calendar year. 10. Prior to the issuance of a building permit the following is required: a. Grading and drainage permits b. Separate easement plat for this project c. Project Disk with all final revisions d. Completion of all required improvements or the placement of a surety with the City (letter of credit, bond, escrow) as required by §158.01 "Guarantees in Lieu of Installed Improvements"to guarantee all incomplete improvements. Further, all improvements necessary to serve the site and protect public safety must be completed, not just guaranteed,prior to the issuance of a Certificate of Occupancy. Background: An Administrative Item was approved by the Planning Commission on April 23, 2001 to allow this project to proceed without the proper street frontage. This approval was conditioned upon approval of a Large Scale Development and limited to six units per lot. The proposed Large Scale Development was reviewed at the May 30, 2001 Technical Plat review and was tabled at the June 14, 2001 Subdivision Committee meeting due to several corrections that were requested to be added to the plan. The project was presented to the Subdivision Committee again on June 28, 2001. Discussion at the Subdivision Committee meeting included the proposed site density,tree preservation, traffic, and sewer capacity. The Subdivision Committee forwarded the Large Scale Development to the full Planning Commission Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.2 LSD 01-19.00 subject to all staff comments. Page 3 INFRASTRUCTURE: a) Water. Existing b) Sanitary sewer would have to be extended to serve this property. See the attached memo regarding the sewer system on Mount Sequoyah . c) Streets. Seethe conditions of approval. d) Grading and Drainage. A preliminary grading plan and drainage report has been submitted. A final plan and report will be required prior to beginning construction. PLANNING COMMISSION ACTION: yes Required Approved Denied Date: Comments: CITY COUNCIL ACTION: Required Approved Denied Date: The "CONDITIONS OF APPROVAL", beginning on page one of this report, are accepted in total without exception by the entity requesting approval of this development item. by title date Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.3 FAYETTEVILLE THE CITY OF FAYETTEVILLE,ARKANSAS 113 W. Mountain St. Fayetteville,AR 72701 Telephone:501-575-8264 ENGINEERING DIVISION CORRESPONDENCE TO: Planning Commission Members FROM: Ron Petrie P.E., Staff Engineer DATE: July 5, 2001 SUBJECT: Hometown Development (LSD 01-19.00) Sanitary Sewer Capacity on Mount Sequoyah When this project was presented to the Subdivision Committee on June 28, 2001, a nearby property owner voiced concerns about the existing sanitary sewer system on Mount Sequoyah. The Subdivision Committee requested that the Engineering Division provide additional information regarding the sewer system in this area and determine the effects of this proposed development on this portion of the system. A map is attached that shows the existing sanitary sewer system on Mount Seqouyah with the proposed development site shown. Also shown on the map are two different sewer main branches that are labeled Lateral No. I and Lateral No. 2. The proposed development would have to extend a sewer main from Lateral No. 2 due to the topography. This connection would either be from the existing sewer main shown on Fletcher Avenue or from Olive Avenue. The sewer lines that comprise Lateral No. 2 are a minimum of eight inches (8") in diameter. According to the Water/Sewer Superintendent,there have been no complaints of overflows on this lateral. This existing line would easily have the capacity to serve this development. The portion of the sewer system labeled Lateral No. 1 is comprised of six inch(6") diameter sewer pipes in which several complaints have been received by the Water/Sewer Superintendent of overflows primarily due to stormwater infiltration during heavy rainfalls. As stated previously, this development could not connect to this portion of the system due to the topography. According to the Capital Improvements Program,this portion of the system is scheduled for replacement and/or improvements in the year 2002. Currently there is $405,000.00 budgeted this year and $1,995,000.00 budgeted next year for this project. If actual flow data and capacity studies are needed by the Planning Commission, additional time would have to be provided in order to provide the calculations. It is the Engineering Division's and Water/Sewer Superintendent's opinion that Lateral No. 2 has sufficient capacity for this development. Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.4 t''c-� WAS h�IGIO a 1 C:) 4 L. - - If - _ �- 00 y -- I ~ I I I � p CID I Oco — CD LATE CD -.-- CD "INO. 2 , 1 � I CD SITE I ---- .. I - - I tt 1 1 I I I I I I 1 I 11 I - �� i I i I � ' � I , illllll � IIII I li � , I _ I es I 1 1 A I 1 I LATERAL NO. 1 1' I - f/ / — f i1 I ---�. - Planning Commission , LSD01-19 Hometown Development Page 2.5 zo*d -iClol FAYETTEV Y LLE THE CITY OF FAYMEVILLE,ARKANSAS - DEPARTMENTAL CORRESPONDENCE TO: Sara Edwards, Associate Planner FROM: Perry Franklin,Traffic Division Superintendent 4 DATE: April 23, 2001 SUBJECT: Sight distance for new development(Mr. Brian Dandy) at the SW corner of Rodgers Dr. and Lighton Trail 1 have checked the above location for adequate sight distance. I exited the property from the existing gravel drive to check the sight distance. The gravel drive and the 24'drive shown west of it would both have adequate sight distance if the vegetation to the east is trimmed back a couple of feet. Both Rodgers Dr. and Lighton Trail have a stop sign for west bound traffic coming down the hill towards this proposed drive. Sight distance to the west is unobscured. The drive should be located as far to the west as is practical to serve the property. If I can help you any further,please let me know. PLF/plf Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.6 FnIFA'd A6bg! b74 TOS *nIQ i33HIS — Audi do , FAYETTEVILLE THE CITY OF FAYETTEVILLE, ARKANSAS MEMORANDUM TO: Subdivision Committee COPY: Sara Edwards, Planning FROM: Kim J. Hesse, Landscape Administrator DATE: June 14, 2001 This memo addresses the tree preservation plan for Hometown Developments. After consultation with the City Attorney's office, it is apparent that either the applicant can be fined for violating the tree preservation ordinance by removing existing trees prior to development review or the clause pertaining to prior tree removal may apply. Public sentiment has appeared to favor requiring additional replacement versus minimal fines. In this event I recommend that additional replacement be required. This property is zoned R-2 and will require a 30% canopy replacement required by the "prior tree removal" clause. This will equate to 8 large replacement trees which will require a total of 3200 square feet of planting space (open land not in utility easements, rights-of-way, or the like) to ensure proper growing space. Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.7 City of Fayetteville •-....-----Tree Preservation Application &Plan Requirements.....- .. Applicant-Name: �l ._ . .:.L�nr/�% L-! -Date: . .. 5% l_.-U/�_. Project Name: Plat Pagem _!5�q Location: 3 20 Z(c Zoning: R- 2- ZONING: ZONING: % MIN.CANOPY % Tree Canopy ❑ RE Residential Estate 25% Required to be Preserved 20% p RA Residential Acre 25%. q ❑ RL Residential Large Lot 20% ❑ RS Residential Small Lot 20% Total Area of Site: ❑ R-1 Low Density Residential 25% Acres: 4- Sy ❑ R-1.5 Moderate Density Residential 20% Square Feet: 2/,7�� � R-2 Medium.Density Residential 20% ❑ R-3 High Density Residential 20% ❑. R-O -Office and..P-rofessionat—...___ -_20%_.. Total Area of Exi ree Canopy: ❑ C-1 Neighborhood Commercial 20% 02S Acres: ❑ C-2 Thoroughfare Commercial 15% quare Feet: togs ❑ C-3 Central Business 15% ❑ C-4 Downtown Commercial 10% h of Total Site Area` ❑ 1-1 Light Industrial/Heavy Commercial 15% —-— — p—1=2 Reavy fndustnar '— - 15% ❑ P-1 Institutional 25% Existing -- Acres: O. Square Feet: 727_74T % of Total Site Area: °v Replacement Tree Canopy: Must have previous approval by Landscape Administrator Acres: Square Feet: % of Total Site Area: Total Canopy: (Preserved Tree Canopy +Replacement Canopy as approved) Acres: Square Feet: % of Total Site Area: - ��C S EXrs7 Vii✓ -)`/ � -S�7E 1` S V2Va� Ntoi e uxts ��/ i2,0 Ui Wt lel 6.e f�/Gespv v�d The fee for Tree Preservation is $120.00 and can be paid at the Planning Office in the City Administration. For further clarification, see the attached step by step process for tree preservation plans, or contact the Landscape Administrator at 575-8308. Revised s-26- 0 tree.a Planning Commission p July 9, 2001 (� �� A I LSD01-19 Hometown Development \V�x {v G Page 2.8 To Whom It May Concern: I'm not necessarily opposed to higher density zoning in town, but if that new multiplex is built,the developer should pay the real infrastructure cost of the complex.I mean both the obvious costs and the hidden costs,and maybe even "civic duty" costs.Instead of requiring the developer to put 20 yards of sidewalk in front of the property,the city should be forcing him to go above and beyond—to pay for sidewalk installation from the curve on Fletcher to the Rodgers intersection, or to pay the city for capital improvements to that naked patch of grass across the street that we call a park. My residence is on a stretch of Rodgers that City Planning and time have forgotten,even though these houses have stood for 50 years.My neighbors and I don't even have the benefit of a sewer main under our street, so we need to own and maintain underground sewage tanks and lift station pumps to push our waste uphill to the sewer line on Lighton Trail. Our forgotten stretch suffers without any sidewalk of footpath, and the street is so narrow it makes walking downright hazardous. Further east on our dead-end drive,the Southern Heights subdivision enjoys sewer lines,sidewalks,and safe street widths,and of course these residents must drive back and forth to town right past our houses,on our substandard stretch of road. Fletcher and Summit are just as bad—the curve on Fletcher being the worst,by far,as cars from further up Mt. Sequoyah roll down at unsafe speeds.It is flat out crazy to walk or ride a bike around that curve as it is, and if we allow another 50 cars or so to use these residential streets,we are flirting with disaster. In my opinion, if the city allows this development,and others like it,we should be forcing the developers to offset the impact with real capital infrastructure improvements.I say,when they install sewer service for the multiplex,make them split the cost of a sewer main that picks up the forgotten section of Rodgers. Make them pay for sidewalks on Fletcher,on Rodgers,and around the park. Make them widen the streets on Fletcher, Summit,and Rodgers,especially on the two hazardous,blind corners where I see so many near misses.Make them buy playground equipment for the park across the street. Force them to commit to funding real infrastructure improvements in the immediate impact zone of this development.And if they refuse,deny or retract the permit,rezone the property,and send them packing. We toss around the phrase"quality of life"so often now that is has become cliche.But here we have a living,breathing example of a real quality of life issue,we have an opportunity to pull the phrase into having real meaning again. And this is what it means:if this development improves the quality of daily life for my neighbors and me,then I am not opposed to it.But if this multiplex goes up,and there are no tangible benefits to the immediate surrounding neighborhood,then I am wholeheartedly against it. Timothy Caffrey 824 E.Rodgers Fayetteville AR 72701 501-442-7013 Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.9 LSD01 - 19 Ho oetown Developn gent Close Up Q Q El C� R-1 R-2 El R-I R-2 Subject Property O R-2 O R-1 Master Street Plan Freeway/Expressway N N Principal Arterial Minor Arterial W E Collector Historical Collector ^,✓ STREETS s 200 0 200 400 600 Feet Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.10 v FAYETTEVILLE THE CITY OF FAYETTEVILLE,ARKANSAS 113 W. Mountain St. Fayetteville,AR 72701 Telephone:(501)575-8264 PLANNING DIVISION CORRESPONDENCE TO: Fayetteville Planning Commission FROM: Sara Edwards,Associate Planner THRU: Tim Conklin, City Planner DATE: April 19, 2001 AD 01-11.00: Administrative Item (Dandy, pp 524) was submitted by Brian Dandy and Robert Schmitt for property located on lots 1,2, & 3 of City Addition. The property is zoned R-2, Medium Density Residential. The request is to build multi-family units on two lots without street frontage. Findings: The applicant is requesting a waiver of the requirement that all new structures be located on a lot which has frontage on a public street. Recently, a property line adjustment has been approved for this property which decreased the number of lots from three to two. Each lot is approximately .5 acres. Currently, the property has frontage on undeveloped city owned right-of- way for the extension of Center Street. The right-of-way for Center Street in this location runs parallel to Fletcher Street. At this time staff feels that the both the topography and the location of the intersection prohibit the construction of Center Street in this location. Recommendation: Approval subject to the Planning Commission finding that the conditions below have been met. Conditions to Address/Discuss: 1. In order to grant the requested waiver the Planning Commission must make findings with regard to the following: The property owner shall make safe and convenient access for fire protection and sanitation vehicles. All structures shall be located on lots as to provide safe, convenient access for servicing, fire protection, and required off-street parking. 2. The density shall be limited to six units per lot.. The applicant is proposing to construct one six-plex on each lot. The density allowed in an R-2 zone is twenty four units per acre by right. This equals approximately 12 units per lot. 3. Each lot shall be required to go through the large scale development process. Any approval with regard to a variance for street frontage shall not be considered an approval of site design. Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.12 This project will be reviewed by applicable City staff and further conditions or revisions will be required. Relevant Code Sections: §164.05 STRUCTURES TO HAVE ACCESS. Every building hereafter erected or moved shall be located on a lot which has frontage on a public street; provided, the Planning Commission shall have the authority to waive this requirement where the property owner provides safe and convenient access for fire protection and sanitation vehicles. All structures shall be so located on lots as to provide safe and convenient access for servicing, fire protection, and required off-street parking. CHAPTER 151:DEFINITIONS Lot. (Zoning) A parcel of land of at least sufficient size to meet minimum zoning requirements for use, coverage and area, and to provide such yards and other open spaces as are herein required. The term includes the words "plot" or"parcel". Such lot shall have frontage on an improved public street, and may consist of: A. A single lot of record; B. A portion of a lot of record; C. A combination of complete lots of record, of complete lots of record and portions of lots of record, or of portions of lots of record; D. A parcel of land described by metes and bounds; provided that in no case of division or combinations shall any residential lot or parcel be created which does not meet the requirements of the Zoning Regulations, Chapter 167. §161.06 DISTRICT R-2 MEDIUM DENSITY RESIDENTIAL. A. Purpose. The High Density Appeal to the Planning Commission. Residential District is designed to permit Unit 2 City-Wide Uses by Conditional and encourage the developing of a variety of Use Permit. dwelling types in suitable environments in a variety of densities. Unit 3 Public Protection and Utility Facilities B. Uses. Unit 4 Cultural and Recreational 1. Uses Permitted. Facilities Unit 1 City-Wide Uses by.Right Unit 11 Mobile Home Park Unit 8 Single-Family Dwellings Unit 25 Professional Offices Unit 9 Multifamily Dwellings - C. Density. Medium Density Families Per Acre 4 to 24 2. Uses Permissible on Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.13 D. Bulk and Area Regulations. Fraternity or 1,000 Sq. Ft. per 1. Lot Width Minimum. Sorority Resident Mobile Home Park 100 Feet Lot within a 50 Feet E. Yard Requirements (feet). Mobile Home Park FRONT SIDE REAR One Family 60 Feet YARD YARD YARD Two Family 60 Feet 25 8 25 Three or More 90 Feet Cross Reference: Variances Chapter 156. Professional 100 Feet F. Height Regulations. Any Offices building which exceeds the height of 20 feet shall be set back from any side boundary 2. Lot Area Minimum. line an additional distance of one foot for Mobile Home Park 3 Acres each foot of height in excess of 20 feet. Lot Within a 4,200 Sq. Ft. (Code 1991, § 160.033; Code 1965, App. Mobile Home Park A, Art. 5(I1I); Ord. No. 2320, 4-5-77; Ord. Row House: No. 2700, 2-2-81) Development 10,000 Sq. Ft. Individual Lot 2,500 Sq. Ft. Single-Family 6,000 Sq. Ft. Two-Family 7,000 Sq. Ft. Three or More 9,000 Sq. Ft. Fraternity or 2 Acres Sorority Professional 1 Acre Offices 3. Land Area Per Dwelling Unit. Mobile Home 3,000 Sq. Ft. Apartments: Two or More 2,000 Sq. Ft. Bedrooms One Bedroom 1,700 Sq. Ft. No Bedroom 1,700 Sq. Ft. Planning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.14 ' F 4{'F CEWTER SL R6W 30F P.O.B. N P.O.D. E CORNER P LIGHTON ST NW CORNER N 89'57'30^W 188.52' L #2 CORNER rVT' .� 'ti 62.50' - 62. 2' - - 63.6 LOT#1 PARCEL B 94.26'--��� 94.26' PARCEL A H/ E N (N Pop S v _ CF -N w PJ+ .N N p OLD LOT LINE 3 3 2 3 gn o N"^p 1 pnp LEGEND r "Nl y o o v y N 0 SET IRON PIN y . W X FOUND CHISELED 'X' T. OO FOUND COTTON SPINDLE o PARCEL; B a PARCEL An • FOUND IRON PIN to NE N LOT LINA u i VICINITY MAP, W PRINC O Y 3 � 5 KILN a61. 3 0 6 75.71' t 94.34' SITE Roocsns OR �T "4J ROCK �*E aN�i 47.95' -.�62 � N89'58'56^E 170.05' `g oa' \ a�� br LAL DESCRIPTION (LOT#1 r� LOT I OF CITY ADDITION TO THE CITY OF FAYETTEVILLE,ARKANSAS AND FAYETTEVILLE, ARKANSAS BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS.BEGINNING AT THE HE CORNER OF SAID LOT I THENCE N89°57'30'W 63.60 FEET, THENCE LEGAL DESCRIPTION' !PARCEL Al S01°07'00'W 247.26 FEET, THENCE N89-58.56E63.61 FEET, THENCE NOI'06'57'E 247.19 FEET TO THE P.O.B.;CONTAINING 0.36 ACRES MORE OR LOT I AND PART OF LOT 2 Of CITY ADDITION TO THE CITY OF LESS FAYETTEVILLE,ARKANSAS AND BEING MORE PARTICULARLY DESCRIBED AS LEGAL DESCRIPTION (LOT#21 FOLLOWS;BEGINNING AT THE HE CORNER OF SAID LOT I THENCE N89'57'30'W 94.26 FEET, THENCE SOI'08'05'W 247.29 FEET, THENCE LOT 2 Of CITY ADDITION TO THE CITY OF FAYETTEVILLE,ARKANSAS AND N89'58'56'E 94.34 FEET, THENCE NOI-06.57-E 24219 FEET TO THE BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS;BEGINNING AT THE NE P.O.S.;CONTAINING 0.54 ACRES MORE OR LESS. CORNER OF SAID LOT 2 THENCE N89°57'30'W 62.42 FEET, THENCE LEGAL DESCRIPTION' (PARCEL B) Sol'07'59'W 247.32 FEET, THENCE N89°58'56E 62.49 FEET, THENCE N01°07'00'E Z47.26 FEET TO THE P.O.B.;CONTAINING 0.35 ACRES MORE OR LESS. PART OF LOT 2 AND PART OF LOT 3 OF CITY ADDITION TO THE CITY OF FAYETTEVILLB,ARKANSAS AND BEING MORE PARTICULARLY DESCRIBED LEGAL DESCRIPTION, (LOT#J) AS FOLLOWS:BEGINNING AT THE NW CORNER Of SAID LOT 3 THENCE SOI°09'13'W 211.37 FEET, THENCE S26°26'45E 40.12 FEET, THENCE PART OF LOT 3 OF CITY ADDITION TO THE CITY Of FAYETTEVILLE. N89°58'56'E 75.71 FEET, THENCE N01'08'05'E 247.29 FEET, THENCE ARKANSAS AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS;BEGINNING N89°57'30'W 94.26 FEET TO THE P.O.B.;CONTAINING 0.53 ACRES AT THE NW COMFIT OF SAID LOT 3 THENCE SOIV9'13'W 211.37 FEET, MORE OR LESS. THENCE S26-2645E 40.12 FEET, THENCE N89°58'56 E 43.95 FEET THENCE N01°07'59E 247.31 FEET, THENCE N6"7'50'W 62.50 FEET TO THE P.O.B.;CONTAINING 0.35 ACRES MORE OR LESS. - JORGENSEN & ASSOCIATES, INC. �GZSTgR� , ;, ENGINEERS SURVEYORS ATE Oe'•-d ®� NO 11118 124 WEST SUNBRIDGE SUITE 5 b O= FAYETTEVILLE,AR 72703 =O t smnKTUBB PH 501.442-9127 FAX 50 1-582,4807 �JY .:pow;:�`"' SCAEE: 1"=50' JOB#: CHECKED BY: DRAWN BY:BJR 1 ..G. JOR. DLJ C19RuVMWRIHLTOR.4TW DATE:22FEB01 "I'I.I I i i.Io- LOT LINE ADJUSTMENT FOR BOB SCHMITT nning Commission July 9, 2001 LSD01-19 Hometown Development Page 2.15