HomeMy WebLinkAbout2007-08-13 - Agendas - FinalTayelteyi;le
113 W. Mountain St.
Fayetteville, AR 72701
Telephone: (479) 575-8267
AGENDA FOR A MEETING OF THE
PLANNING COMMISSION
Monday, July 23, 2007, 5:30 p.m.
Room 219, City Administration Building
ORDER OF PLANNING COMMISSION MEETING
A. Introduction of agenda item — Chair
B. Presentation of Staff Report
C. Public Comment
D. Presentation of request — Applicant
E. Questions & Answer with Commission
F. Action of Planning Commission (Discussion & Vote)
NOTE TO MEMBERS OF THE AUDIENCE
If you wish to address the Planning Commission on an agenda item please queue behind the podium when
the Chair asks for public comment. Public comment occurs after the Planning Staff has presented the
application and will only be permitted during this part of the hearing for each item. Members of the public
are permitted a maximum of 10 minutes to speak; representatives of a neighborhood group will be allowed
20 minutes. The applicant/representative of an application before the Planning Commission for
consideration will be permitted a maximum of 20 minutes for presentation.
Once the Chair recognizes you, go to the podium at the front of the room and give your name and address.
Address your comments to the Chair, who is the presiding officer. He/She will direct them to the
appropriate appointed official, staff member or others for response. Open dialogue will not be permitted:
please ask any questions, and answers will be provided once public comment has been closed. Please keep
your comments brief, to the point, and relevant to the agenda item being considered so that everyone
has a chance to speak.
Please, as a matter of courtesy, refrain from applauding or booing any speakers or actions of the Planning
Commission.
2007 Planning Commissioners
Jill Anthes
Lois Bryant Matthew Cabe
James Graves Porter Winston
Audy Lack Christine Myres
Alan Ostner Sean Trumbo
rye'Ficylle
TENTATIVE AGENDA
113 W. Mountain St.
Fayetteville, AR 72701
Telephone: (479) 575-8267
AGENDA FOR A MEETING OF THE
PLANNING COMMISSION
Monday, August 13, 2007, 5:30 p.m.
Room 219, City Administration Building
The following items will be considered:
Consent:
1. Approval of the minutes from the July 23, 2007 Planning Commission meeting.
2. ADM 07-2695: (FAYETTEVILLE DIAGNOSTIC CLINIC): Submitted by PATRICK HARGUS
ENGINEERING DESIGN ASSOCIATES for property located at 3344 N. FUTRALL DRIVE. The
property is zoned R -O, RESIDENTIAL OFFICE and contains approximately 1.11 acres. The request is for
a one-year extension on the approval of the Fayetteville Diagnostic Clinic, LSD 06-2197.
Planner: Dara Sanders
Old Business:
3. ADM 07-2625: (Master Street Plan Update): Submitted by Planning Staff, recommending
amendments to and adoption of the Master Street Plan for the City of Fayetteville.
New Business:
4. LSD 07-2633: Large Scale Development (WALGREEN'S @ 6TH & ONE MILE RD, 558):
Submitted by JEFFERY NICHOLAS SPRINGFIELD HOLDING GROUP,LLC for property located at
2964 W 6TH ST.@ THE INTERSECTION OF ONE MILE ROAD. The property is zoned C-2,
THOROUGHFARE COMMERCIAL and contains approximately 1.96 acres. The request is to approve a
13,659 s.f. retail building with associated parking. Planner: Jesse Fulcher
5. CUP 07-2666: (VERIZON WIRELESS SANG AVENUE, 481): Submitted by WOODEN, FULTON
& SCARBOROUGH, P.C. for property located at THE SANG AVENUE WATER TOWER SITE. The
property is zoned RSF-4, SINGLE FAMILY - 4 UNITS/ACRE and contains approximately 0.13 acres.
The request is for a 150' wireless communication facility on the subject property. Planner: Andrew Garner
6. CUP 07-2668: (VERIZON ALLIED STORAGE, 601): Submitted by WOODEN, FULTON &
SCARBOROUGH, P.C. for property located at 85 W. 15TH STREET. The property is zoned I-1, HEAVY
COMMERCIAL/LIGHT INDUST and contains approximately 14.98 acres. The request is for a 130'
wireless communication facility on the subject property. Planner: Jesse Fulcher
7. RZN 07-2667: (HOBSON INC., 433): Submitted by DONALD E. WILSON for property located at
7613 WEDINGTON (12611 HWY 16W). The property is zoned R -A, RESIDENTIAL -AGRICULTURAL
and contains approximately 2.38 acres. The request is to rezone the subject property to C-2, Thoroughfare
Commercial. Planner: Andrew Gamer
8. RZN 07-2669: (PREMIUM BRANDS/ARKA, Inc., 560): Submitted by PREMIUM BRANDS for
property located at 1030 RAZORBACK ROAD, S OF HWY 62. The property is zoned I-1, HEAVY
COMMERCIAL/LIGHT INDUST and contains approximately 14.68 acres. The request is to rezone the
subject property to C-2, Thoroughfare Commercial. Planner: Jesse Fulcher
9. R-PZD 07-2634: Planned Zoning District (THE COVES @ WALNUT CROSSING, 555):
Submitted by RAUSCH COLEMAN HOMES for property located at N OF HWY 62W AND W OF
WALNUT CROSSING PZD. The property is zoned RSF-1, SINGLE FAMILY - 1 UNIT/ACRE and
contains approximately 50.40 acres. The request is to for Zoning and Land Use approval for a Residential
Planned Zoning District with 184 single family dwelling units. Planner: Jesse Fulcher
10. Fayetteville Downtown Cultural Arts District. Recommendation to the Planning Commission and
City Council by Fayetteville Downtown Partners and the Cultural Arts District Committee (a subcommittee
established by the Chair of the Planning Commission) to establish a Cultural Arts District, identified as
roughly Maple Street to Sixth Street and Arkansas Avenue to College Avenue/South School.
All interested parties may appear and be heard at the public hearings. A copy of the proposed amendments and other pertinent data
are open and available for inspection in the office of City Planning (575-8267), 125 West Mountain Street, Fayetteville, Arkansas. All
interested parties are invited to review the petitions. Interpreters or TDD for hearing impaired are available for all public hearings; 72
hour notice is required. For further information or to request an interpreter, please call 575-8330.
THE CITY OF FAYETTEVILLE, ARKANSAS
PLANNING DIVISION CORRESPONDENCE
TO: Fayetteville Planning Commission
FROM: Dara Sanders, Associate Planner
THRU: Jeremy Pate, Director of Current Planning
DATE: August 03, 2007
PC Meeting of August 13, 2007
125 W. Mountain St.
Fayetteville, AR 72701
Telephone: (479) 575-8267
ADM 07-2695: Administrative Item (FAYETTEVILLE DIAGNOSTIC CLINIC, 212):
Submitted by PATRICK HARGUS ENGINEERING DESIGN ASSOCIATES for property
located at 3344 N. FUTRALL DRIVE. The property is zoned R -O, RESIDENTIAL OFFICE
and contains approximately 1.11 acres. The request is for a one-year extensionof the approval of
the Fayetteville Diagnostic Clinic, LSD 06-2197.
Planner: Dara Sanders
BACKGROUND
Property Description:: The subject property is Lot 7 of the North Hills Medical Park Planned Unit
Development (PUD). The subdivision is zoned R -O, Residential Office land :located within the
Design Overlay District. The addition to the rear of the building will be a 2 story addition with 1,260
square feet per floor for a total of 2,520 square feet. The addition to the front of the building is a2°a
floor addition with 1,457 square feet.
Background: The original Large Scale Development for the project was approved by the Planning
Commission on August 17, 2006. The reason that the construction of the project has been delayed is
due to finacial considerations involved in the puchase of the MRI equipment for this facility.
Proposal: The applicant requests to extend the approval of the Large Scale Development for one
year, to expire on August 17, 2008. The Planning Department received the applicant's extension
request on August 06, 2007, within the required one year time limit. Should this; extension be..,
granted, all permits are required to be issued before the one-year extended deadline. If the permits are
not issued prior to August 17, 2008, all of the approved plans for the project shall be rendered null
and void.
RECOMMENDATION
Planning Staff recommends approval of ADM 07-2695, the requested extension to the LSD 06-2197,
with the following conditions:
1. The applicant shall be allowed until August 17, 2008 to receive all required building permits.
K: IReports120071PC Reports108-l3-071,4DM 07-2695 (Fayetteville Diagnostic Clinic Extension).doc
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 1 of 12
If all permits have not been received by this time, the Large Scale Development approval
shall be revoked.
2. All other conditions of approval for the project shall remain applicable.
DISCUSSION
The City of Fayetteville Unified Development Code (UDC) Section 166.20(b) gives the Planning
Commission authority to extend approval of a large scale development one additional year from the
original approval. In order to extend this approval, the applicant must: (1) request the extension
prior to the one year time limit, and (2) show good cause why the tasks could not reasonably be
completed within the normal one year. If the one year extension is granted, it is within this time that
the applicant shall receive all permits and approvals as required by City, State, and Federal
regulations to start construction of the development or project.
(1) The applicant has submitted the extension request to the Planning Division on August 06,
2007, prior to the one year time limit ending on August 17, 2007.
(2) The applicant has stated that financial considerations involved in the puchase of the MRI
equipment has delayed this project, but that they plan to move forward upon resolution of
this matter.
K:1 Reparls12007tPC Reports108-13-071ADM 07-2695 (Fayetteville Diagnostic Clinic Extension).doc
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 2 of 12
CHAPTER 166: DEVELOPMENT
166.20 Expiration Of Approved Plans
And Permits
(A) Applicability. The provisions of this
section apply to all of the following plans
and permits:
(1) Preliminary plats;
(2) Planned zoning district developments;
(3) Conditional uses;
(4) Large-scale developments;
(5) Lot splits;
(6) Physical alteration of land permits;
(7) Storm water, drainage, and erosion control
permits;
(8) Tree preservation plans;
(9) Sign permits; and,
(10) Floodplain development permits.
(B) One-year time limit.
(1) Tasks to be completed. All of the above -
enumerated plans and permits are
conditioned upon the applicant
accomplishing the following tasks within
one (1) year from the date of approval:
(a) For any renovation or new
construction, receive a building
permit; and/or,
(b) For a lot split, record a deed or
survey at the Washington County
Circuit Clerk's Office,
stamped for recordation by the City
Planning Division; and/or,
(c) Receive a Certificate of Zoning
Compliance; and/or,
(d) Receive all permits and approvals
required by City, State, and Federal
regulations to start construction of
the development or project.
be completed within the normal one (1)
year limit.
Expiration. If the required task(s) are not
completed within one (1) year from the
date of approval or during an allowed
extension period, all of the above -
enumerated plans and permits shall be
rendered null and void.
(C) Three-year time limit.
(1) Tasks to be complete. All of the above -
enumerated plans and permits are also
conditioned upon the applicant completing
the project and receiving final inspection
approval and/or a final Certificate of
Occupancy permit within three (3) years
from the date of issuance of a Building
Permit.
(2) Extensions. Prior to the expiration of the
three (3) year time limit, an applicant may
request the Planning Commission to
extend the three (3) year period to
complete the project by up to two (2)
additional years. The applicant has the
burden to show good cause why the
project could not reasonably be completed
within the three (3) year time limit.
(3) Expiration. If the applicant fails to meet
the requirements of subsection (C)(1)
within three (3) years from the date of
issuance ofa Building Permit or during an
allowed extension period, all of the above -
enumerated plans and permits, shall be
rendered null and void.
(2) Extensions. Prior to the expiration of the
one (1) year time limit, an applicant may
request the Planning Commission to
extend the period to accomplish the tasks
by up to one (1) additional year. The
applicant has the burden to show good
cause why the tasks could not reasonably
K: IReports120071PC Reportr108-13-071ADM 07-2695 (Fayetteville Diagnostic Clinic Extension).doc
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 3 of 12
ENGINEERING DESIGN ASSOCIATES, P.A.
134 WEST EMMA AVENUE
SPRINGDALE, ARKANSAS 72764
479-756-1266
Fax: 479-756-2129
August 6, 2007
RE: Fayetteville Diagnostic Clinic LSD.
Dear Mr. Pate,
On behalf of Materia Medica, LLC, whose address is 3344 Futrall Dr., Fayetteville, AR, we would like to
request an extension to the LSD approval for The Fayetteville Diagnostic Clinic. The expiration date on the
approval is 8-17-07. The development is a building expansion to the existing building located on lot 7 of the
North Hills Medical Park.
Due to financial considerations involved in the purchase of the MRI equipment the project was put on hold.
Please let me know if you require anything else to process this request.
Best regards,
ottr
Patrick Hargus, RYLA
Engineering Design Associates, P.A.
Ph. 479-756-1266
4 l
RECEIVED
AUG 0 6 2007
CITY OF FAYETTEVILLE
PLANNING DIVISION
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 4 of 12
THE CITY OF FAYETTEVILLE, ARKANSAS
PLANNING DIVISION CORRESPONDENCE
TO: Subdivision Committee Members
FROM: Suzanne Morgan, Current Planner
Matt Casey, Assistant City Engineer
THRU: Jeremy Pate, Director of Current Planning
DATE: August 16, 2006 Updated August 22, 2006
LSD 06-2197
Page 1
SC Meeting of August 17, 2006
125 W. Mountain St.
Fayetteville, AR 72701
Telephone: (479) 575-8267
LSD 06-2197: Large Scale Development (FAYETTEVILLE DIAGNOSTIC CLINIC, 212):
Submitted by PATRICK HARGUS ENGINEERING DESIGN ASSOCIATES for property located at
3344 N. FUTRALL DRIVE. The property is zoned R -O, RESIDENTIAL OFFICE and contains
approximately 1.11 acres. The request is for an addition of approximately 4,000 s.f. to the existing
2 -story medical office building. Planner: Suzanne Morgan
Findings:
Property Description: The subject property is Lot 7 of the North Hills Medical Park Planned Unit:
Development (PUD). The subdivision is zoned R -O, Residential Office and::located within the
Design Overlay District. As a PUD, the bulk and area regulations are varied from :the standard R-0
requirements. Namely, there are no building setback requirements from side and rear property line;..
however, all building shall be separated in accordance with Building Safety and Fire Code
regulations.
Proposal: Any development within the Design Overlay District requires Large Scale Development
Approval. The applicant requests approval to construct an approximately 4,000 square foot addition
to the existing Fayetteville Diagnostic Clinic. A two-story, 2,520 square foot addition will be made
to the southwest corner of the structure and a 1,460 square foot addition is requested over the main
entrance. The existing canopy which overhangs the sidewalk and connectsalllots within the
subdivision will be reconstructed around the new corner of the structure. It will encroach into the
Common Property; approval of this encroachment has been granted from the POA (see attached
letter).
Parking: Parking for all lots within the subdivision is shared and was provided with the
development of the Medical Park. The existing parking is adequate for full build -out of the
subdivision.
Right-of-way being dedicated: Sufficient right-of-way was dedicated with the final plat for
Northhills Medical Park.
Adjacent Master Street Plan Streets: Northhills Blvd (Collector)
K:: IReports120061SC Reports108-17-061LSD 06-2197 (Fayetteville Diagnostic Clinic).doc
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 5 of 12
LSD 06-2197
Page 2
Street Improvements: No street improvements are required.
Tree Preservation:
Existing canopy: 35.4%
Preserved canopy: 33.4%
Reqiured canopy: 20%
Mitigation: None
Surrounding Land Use / Zoning
Direction
Land Use
Zoning
North
Parking
R -O (PUD)
South
Common Area
R -O (PUD)
East
Medical Office
R -O (PUD)
West
Medical Office
R -O (PUD)
Building Area.: On any lot within the R -O zoning district, the area occupied by all buildings shall not
exceed 60% of the total area of such lot. The building, not including the area covered by the
walkway overhang, occupies 48.1% of the total area of the lot.
Design Overlay District:
• Greenspace:
• Curb Cuts:
• Lighting:
• Exterior Appearance:
• Building Material:
Site Coverage:
The overall property is developed. The proposed addition
does not encroach within the required 25' greenspace
requirement along adjacent rights-of-way.
Several sign variances were granted for the Medical Park.
Any new signs shall comply with existing ordinances.
No new curb cuts are proposed.
The development shall comply with lighting requirements.
Elevations have been submitted for the addition which will
match the materials and colors of the existing structure. The
building is matches the theme of the design for the overall
Medical Park. Planning Commission determination of
architectural treatment of fronts, along with Commercial
Design Standards, is required.
The materials consist of masonry and natural looking
materials as required in the Design Overlay District.
Twenty-five percent (25%) of the site shall be left in open
space. The percent of the site occupied by structures and
surfaced area post construction is 65%.
K' Reportsl20061SC Reports108-17-061LSD 06-2197 (Fayetteville Diagnostic Clinic).dac
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 6 of 12
LSD 06-2197
Page 3
• Landscaping: The ordinance requires that eighty percent (80%) of the open
space shall be landscaped which may include ponds and
fountains. Staff finds the existing trees and vegetation on the
property sufficient to meet this requirement.
• Fencing: N/A
• Outdoor Storage: N/A
• Access: The Medical Park was platted and developed prior to the
adoption of the Design Overlay District requirements.
Pedestrian access is not provided from the right-of-way to
each individual lot within the subdivision. However,
sidewalks are provided within the common area and between
the structures to provide pedestrian access within the
subdivision.
Recommendation: Staff recommends approval of LSD 06-2197 at the Subdivision Committee
with the following conditions:
Conditions of Approval:
Planning Commission determination and approval of Commercial Design Standards.
Staff finds the submitted elevation drawings to be in compliance with Commercial
Design Standards and Design Overlay District requirements. The materialsand colors
are compatible with the existing and surrounding structures.
Revise the canopy calculations on the Tree Preservation Plan to reflect those in the report
issued by the Urban Forester.
Standard Conditions of approval:
3. All wall and freestanding signs shall be permitted by a separate sign permit application
prior to installation.
4 All exterior lighting shall comply with the City's lighting ordinance. The applicant shall
submit a lighting plan and cut sheets of the proposed light fixtures to Planning Staff for
review prior to issuance of a building permit.
5. All mechanical/utility equipment shall be screened using materials that are compatible
with and incorporated into the structure.
6. Should a trash container be installed on this property, it shall be screened with access not
visible from the street, utilizing materials that are compatible with main structure.
Elevations of the screening materials are required prior to building permit.
KkReports120061SC Reports108-17-061LSD 06-2197 (Fayetteville Diagnostic Clinic).doc
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 7 of 12
LSD 06-2197
Page 4
7. Plat Review and Subdivision comments (to include written staff comments provided to
the applicant or his representative, and all comments from utility representatives - AR
Western Gas, SWBT, Ozarks, SWEPCO, Cox Communications)
8. Staff approval of final detailed plans, specifications and calculations (where applicable)
for grading, drainage, water, sewer, fire protection, streets (public and private),
sidewalks, parking lot(s) and tree preservation. The information submitted for the plat
review process was reviewed for general concept only. All public improvements are
subject to additional review and approval. All improvements shall comply with City's
current requirements.
9. Large scale development shall be valid for one calendar year.
10. Prior to the issuance of a building permit the following is required:
a. Grading and drainage permits
b. Separate easement plat for this project that shall include the tree preservation
area.
c. Project Disk with all final revisions
d. Completion of all required improvements or the placement of a surety with
the City (letter of credit, bond, escrow) as required by Section 158.01
"Guarantees in Lieu of Installed Improvements" to guarantee all incomplete
improvements. Further, all improvements necessary to serve the site and
protect public safety must be completed, not just guaranteed, prior to the
issuance of a Certificate of Occupancy
11. Additional conditions:
Subdivision Committee Action:
Motion: Anthes
Second: Bryant
Vote: 3-0-0
Meeting Date: August 17, 2006
Comments:
✓ Approval O Forwarded to P.C.
The "Conditions of Approval" listed in the report above are accepted in total without exception by
the entity requesting approval of this development item.
Signature Date
K.:IReports120061SCReports108-17-061LSD 06-2197 (Fayetteville Diagnostic Clinic).doc
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 8 of 12
161.15 District R -O, Residential Office
(A) Purpose. The Residential -Office
District is designed primarily to provide
area for offices without limitation to the
nature or size of the office, together with
community facilities, restaurants and
compatible residential uses.
(B) Uses.
11 Permitted uses.
Unit 1
City-wide uses by right
Unit 5
Government facilities
Unit 8
Single-family dwellings
Unit 9
Two-family dwellings
Unit 12
Offices, studios and related services
Unit 25
Professional offices
(2) Conditional uses.
Unit 2
City-wide uses by conditional use permit
Unit 3
Public protection and utility facilities
Unit 4
Cultural and recreational facilities
Unit 11
Manufactured home park
Unit 13
Eating places
Unit 24
Home occupations
Unit 26
Multi -family dwellings
Unit 36
Wireless communications facilities
(C) Bulk and area regulations.
(Per dwelling unit for residential
structures)
(1) Lot Width minimum.
Manufactured home park
100 ft.
Lot within a
park
manufactured home
50 ft.
Single-family
Single-family
60 ft.
Two-family
6,500 sq. ft.
60 ft.
Three or more
Fraternity or Sorority
90 ft.
(2) Lot area minimum.
Manufactured home park
3 acres
Lot within a manufactured home
park
4,200 sq. ft.
Townhouses:
Development
Individual lot
10,000 sq. ft.
2,500 sq. ft.
Single-family
6,000 sq. ft.
Two-family
6,500 sq. ft.
Three or more
8,000 sq. ft.
Fraternity or Sorority
1 acre
LSD 06-2113
Page 5
(3) Land area per dwelling unit.
Manufactured home
3,000 sq. ft.
Townhouses & apartments:
No bedroom
One bedroom
Two or more
bedrooms
1,000 sq. ft.
1,000 sq. ft.
1,200 sq. ft.
Fraternity or Sorority
500 sq. ft. per resident
(D)
Density.
Units per acre
14to24
E) Setback regulations.
Front
30 ft.
Front, if parking is allowed between the right-
of -way and the building
50 ft.
Front, in the Hillside/Hilltop Overlay District
15 ft.
Side
10 ft.
Side, when contiguous to a residential district
15 ft.
Side, in the Hillside/Hilltop Overlay District
8 ft
Rear, without easement or alley
25 ft.
Rear, from center line of public alley
10 ft.
Rear, in the Hillside/Hilltop Overlay District
15 ft.
(F) Height regulations. There shall be no
maximum height limits in R -O Districts
except for the HHOD, provided, however,
that any building that exceeds the height
of 20 feet shall be set back with any
boundary line of any RSF or RMF District
an additional distance of one foot for each
foot of height in excess of 20 feet. In the
Hillside/Hilltop Overlay District the
maximum building height is 60 ft. as
measured from the lowest point of the
structure at the historic grade, prior to
development, to the highest point of the
structure allowing 3 stories on the uphill
side and 4 stories on the downhill side of
the building. If the building is placed on a
graded pad then the height of the building
is reduced allowing a maximum of 3
stories as measured from the historic
grade, pre -development.
(G) Building area. On any lot, the area
occupied by all buildings shall not exceed
60% of the total area of such lot.
K: IReports120061SC Reports108-17-061LSD 06-2197 (Fayetteville Diagnostic Qinic).doc
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 9 of 12
LSD06-2197
Close Up View
FAYETTEVILLE DIAGNOSTIC CLINIC
LONGVIEW ST
Overview
Legend
yUUe o Overlay District — FLOODWAY -----
- 100 YEAR ---
0 75 150
300
500 YEAR
LIMIT OF STUDY
BaseLine Profile
Fayetteville
Outside City
raa
LS006-2197
vector.GDB.Foatprint_2004
Min
Hillside -Hilltop Overlay District
450
600
FeAtDM
August 13, 2007
Planning Commission
)7-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 10 of 12
LSD06-2197
FAYETTEVILLE DIAGNOSTIC CLINIC
One Mile View
RMF -12
A's Pjy5 D0. - -PRIVq
91 „
G1 G2
SUBJECT PROPERTY
C 2 RSFA"
R-0-RSFA -A'
R-0RSF4 tt1S�� RF -4
R-0 R -A RMR-24 I
SFd U �
`T i' _ RMF 24 RMP -24 j "'S
RMF -24
- - RMF261 -89 R-0
2
R-0- ..iO rv-R M1 2➢ R
�- RT -12, RNA -26
R -A
j S _LIMEADE
MEADE ¢
C
R -A BOWERS
PRN4c
_. CASSAf'$r.__ ASSATTST _..
CASSATT $rC
IO RfYN0105
STRANGEDIY
RMF -24
RMF -24
R5(4 RSF,
$FA RSFA
RSFA` :.
RSF-4
RSFA„
RSFA
R$F`
Overview
Legend
Subject Property
LSD06-2197
Boundary
:..• Planning Area
r Overlay District
Outside City
0 0.25 0.5
Legend
Hillside -Hilltop Overlay District
1
M
ADN
'es August 13, 20C
Planning Commissic
07-2695 Fayetteville Diagnostic. Cljg
7
n
c
Agenda Item 2
Page 11 of 12
August 13, 2007
Planning Commission
ADM 07-2695 Fayetteville Diagnostic Clinic
Agenda Item 2
Page 12 of 12
THE CITY OF FAYETTEVILLE, ARKANSAS
PC Meeting of August 13, 2007
125 W. Mountain St.
Fayetteville, AR 72701
PLANNING DIVISION CORRESPONDENCE Telephone: (479) 575-8267
TO: Fayetteville Planning Commission
FROM: Karen Minkel, Senior Long Range Planner PI •
THRU: Tim Conklin, Planning and DevelopmentM nagement Director/1C .
Jeremy Pate, Director of Current Planning
Ron Petrie, City Engineer V R
DATE: July 26, 2007
ADM 07-2625: Administrative Item (Master Street Plan Update): The request is to forward the
proposed Master Street Plan with a recommendation for approval to the City Council.
Planner: Karen Minkel
BACKGROUND
The Planning Commission first reviewed the proposed Master Street Plan at a regular meeting on
July 9, 2007, and the Plan was tabled indefinitely.
The Planning and Engineering staffs were charged with updating the Master Street Plan (MSP) to
reflect the goals of City Plan 2025 and to complement the Future Land Use Map. In addition,
staff wanted to standardize cross-sections in order to minimize the number of requests for
individual street cross-sections in proposed developments. Staff developed the attached street
cross-sections through multiple meetings, and the proposed MSP has been reviewed by the
engineering and planning divisions, the fire department, solid waste division and the urban
forester. Staff also utilized professional guidelines and manuals for the update, including A
Policy on Geometric Design of Highways and Streets by the American Association of State
Highway and Transportation Officials and the proposed Context Sensitive Solutions by the
Institute of Transportation Engineers.
Changes to the map include:
(1) Policy decisions that have been made by the City Council since the last update;
(2) More small, connecting streets, mostly in the form of Collector streets;
(3) Greater sensitivity to the Future Land Use Map;
(4) Classification of streets in the newly annexed area;
(5) Alignment with the Fayetteville Alternative Transportation and Trails Plan; and
(6) Alignment changes to streets based on hillside and floodplain data.
Changes to the street cross-sections include:
K: IReports120071PC Reports108-13-07IADM 07-2625 (Master Street Plan Update).doc
August 13, 2007
Planning Commission
ADM 07-2625 Master Street Plan Update
Agenda Item 3
Page 1 of 42
(1) Better accommodation of pedestrians and cyclists;
(2) Greater sensitivity to context, offering low -impact development, suburban and urban
street cross-section options;
(3) Reduction of curb and gutter from two feet to one -and -a -half feet;
(4) Overall reduction of right-of-way requirements;
(5) Lane width measured from face of curb instead of back of curb in order to better describe
the visual width of the road; and
(6) Downtown street cross-section rights-of-way increased in order to make the downtown
cross-sections consistent with the City's sidewalk and landscaping ordinances.
Street
Previous R -O -W
Proposed R -O -W
Alleys (3)
20'
20', 24' for commercial
alley
Residential
40'
43'
Residential (LID)
N/A
50'
Hillside Residential
27'
27'
Local
50'
50'
Local Urban
N/A
53'
Hillside Local
33'
33'
Collector
70'
59', 70' at intersections
Minor Arterial
90'
85'
Principal Arterial
110'
97'
Principal Arterial
Parkway
N/A
107'
DMP 2 -Lane Urban
30'
37'
DMP 2 -Lane Urban
38'
45'
DMP 1 -Lane Urban
40'
43'
DMP College
N/A/
63'
Staff solicited feedback from four groups before presenting the proposed MSP to the Planning
Commission. The Plan was presented initially to the Street Committee on May 31, 2007 and
members expressed interest in hearing feedback from the public. The Plan was then presented to
utility companies at a meeting hosted by Ozarks Electric. A Master Street Plan Open House was
held at the Town Center Plaza during the Farmers Market on June 23, 2007. Between 50 and 60
citizens took the self -guided walking tour during the Open House and five left comments. The
last input session was held specifically for local engineers and developers to provide comments
on June 26, 2007. Nine engineers, developers and architects attended the session. No changes
were requested.
K:IReports 120071PC Reports108-13-07ADM 07-2625 (Master Street Plan Update).doc
August 13, 2007
Planning Commission
ADM 07-2625 Master Street Plan Update
Agenda Item 3
Page 2 of 42
A second Open House was held at Gulley Park on July 26, 2007 during one of the summer
concerts. Between 150 and 200 citizens viewed the proposed map and street cross-sections. Five
left comments, which are shown below:
What are the strengths of the MSP?
• Providing bike lanes and green space
• Bike lanes
What would you like to see changed in the MSP update?
• Extension of turning lanes whenever possible to prevent bottlenecking
• It looks like a great plan
Are there any important connections missing?
• It appears to be thorough
• Nothing that I know of
• Needs more bike lanes at West Deane St.
• My concern has not been added to the MSP -yet. But it does relate to College
Ave./South School. Rock Street at intersection should be closed. Traffic from
Huntsville Road at Jefferson light should be channeled there. Don't ruin the Spout
Spring Neighborhood by running commuter traffic at high counts through. Many
supporting safety, costs, etc. for this choice. I am suspicious of this. Trust me, the
people in the hollow will not be able to access Huntsville at Rock so don't pretend
to be making this decision for them. This is specifically accommodating
commuters over community. Two blocks, maybe saved by the short cut. No real
time due to curves, etc. Winter -Rock St. vs. S. College? Please re-engineer this
dangerous intersection BUT you can do it with better intentions. Close the Rock
St. access. Channel the 16E traffic down to the Jefferson light.
• I like the improvements that have already been taking place around Wilson Park
with speed bumps and look forward to more of this, and more greenery on College
Ave.
DISCUSSION
Design Speeds: Members of the public and several commissioners had questions about design
speeds and the relationship to lane width. Staff has added the desired operating speed to each
street cross-section as shown in the table below.
Street
Desired Operating Speed
Residential
15-20 mph
Local
20-25 mph
Collector
25-30 mph
Minor Arterial
35-40 mph
Principal Arterial
40-45 mph
K: IReports120071PC Reports108-13-071ADM 07-2625 (Master Street Plan Update).doc
August 13, 2007
Planning Commission
ADM 07-2625 Master Street Plan Update
Agenda Item 3
Page 3 of 42
The Engineering and planning staff also reviewed the proposed Context Sensitive Solutions in
order to reassess the width of travel lanes in the street cross-sections. The travel lane
recommendation for Collector Thoroughfares was 10-11 feet, which is consistent with the
proposed Collector street cross-section. Collector streets that are part of the Trails Master Plan
require a 15 -foot shared motorist and cyclist lane; collector streets without on -street linkages
would have a 10 -foot and a 9' /z -foot travel lane. The desired operating speed of 25-30 mph is
also consistent with the proposed Context Sensitive Solutions.
The recommended travel lane width for arterials with two to four lanes is 10-12 feet depending
on whether the area is residential or commercial. The proposed Master Street Plan is consistent
with this recommendation, requiring 11' travel lanes for Minor and Principal Arterials.
The Context Sensitive Solutions document does not address Residential or Local streets. Staff
reevaluated two of these street cross-section recommendations based on comments from
commissioners and amended the Low Impact Development street cross section and the Hillside
Local street cross-section. Staff reduced the lane widths of the Low -Impact Development street
cross-section by one foot on either side, creating 9' travel lanes, which are consistent with the
standard Residential street cross-section measurements. The two feet were added to the
greenspace to make additional room for trees and maintain the proposed right-of-way of 50 feet.
Commissioners also questioned the width of the Hillside Local street cross-section and asked
whether the 12.5' travel lanes could be reduced. Staff has added 7 -foot on -street parking on one
side to this cross-section, reducing the lane widths to 9.5 feet.
Staff further clarified travel lane widths by measuring the lanes without including the one -foot
gutter section. This change provides a more accurate representation of the lane width as
measured by the Context Sensitive Solutions guide and AASHTO.
Elements of "Green" Neighborhoods: The Planning Commission requested that staff clarify the
"green" neighborhood elements that would accompany the use of the low -impact development
street cross-sections. Staff used the U.S. Green Building CounciI's guide to LEED Neighborhood
Development projects to identify key elements of "green" neighborhoods. Staff also wanted to
provide developers with some flexibility to allow for innovative teelmiques and does not intend
for the listed elements to represent an exhaustive list.
The following text has been added:
The Low -Impact Development street cross-section will be recommended by staff only if
used in conjunction with other "green" neighborhood building practices. These
practices may include, but are not limited to, increasing energy and water efficiency,
decreasing vehicle miles traveled, avoiding floodplains, conserving wetlands and water
bodies, providing a diversity of housing types, utilizing a compact development pattern,
including certified green buildings, minimizing site disturbance through site design
and during construction, decreasing polluted stormwater run-off, building where jobs
and services are accessible by foot or transit, and improving air quality.
Collector Boulevards: In a second review of the proposed Master Street Plan, the fire department
K:IReports120071PCReports108-13-071ADM 07-2625 (Master Street Plan Update).doc
August 13, 2007
Planning Commission
ADM 07-2625 Master Street Plan Update
Agenda Item 3
Page 4 of 42
found that the Collector Boulevard street cross-section was inconsistent with Fayetteville Fire
Code. The fire department requires 20 feet free and clear on either side of the boulevard, not
including on -street parking. Attempting to reconcile this requirement with the Collector
Boulevard concept did not produce a workable standard street cross-section, and Planning and
Engineering staff recommend removing this street cross-section. The fire department has
expressed willingness to work with individual developers who would like to utilize this type of
street cross-section to find an acceptable solution, but staff did not feel comfortable
recommending a standard collector boulevard given the fire code regulations. In addition, staff
has added text that clarifies the fire code requirements when structures of 30 feet or three stories
are utilized. The fire code requires 26 feet free and clear where three-story structures are utilized
in order to accommodate fire apparatus.
Public Comment: In addition, Planning staff received written comments and letters, which are
attached to the report. Letters from Jeff Gaddy and Bob Gaddy support the removal of a proposed
north -south minor arterial east of Oakland Zion Road in favor of upgrading Oakland Zion Road
to a minor arterial. Bob Gaddy further added that the Commission should consider connecting
Sagely Lane to N. Altus Drive rather than extending Sagely Lane to E. Skillern Road. Skillern
Road could then be extended to connect with N. Altus Drive. An email was received from John
McClarty, Transportation Study Director with Northwest Arkansas Regional Planning,
supporting the upgrade of Highway 112 from a minor arterial to a principal arterial parkway,
although Regional Planning preferred N. Salem Road. The Planning Commission received letters
from several members of the Estates at Salem Hills neighborhood opposing the designation of
Howard Nickell as a Principal Arterial Parkway, which are also attached.
RECOMMENDATION: Recommend that the proposed Master Street Plan Update at the
August 13, Planning Commission meeting be forwarded to the City Council with a
recommendation for approval.
K:IReports120071PCReports108-73-07L4DM 07-2625 (Master Street Plan Update).doc
August 13, 2007
Planning Commission
ADM 07-2625 Master Street Plan Update
Agenda Item 3
Page 5 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
Connecting Fayetteville to other population centers and to provide for
circulation within the community requires consistent planning. New
development must be provided with proper access to alleviate problems
associated with congestion and safety by requiring streets in sufficient
number and of adequate size to accommodate peak traffic volumes.
The following street cross-sections are functionally classified in accordance
with the U.S. Department of Transportation's National Highway Functional
Classification Study Manual. In addition, the street cross-sections provide
sensitivity to context by providing options for both suburban and urban
developments and accommodating cyclists and low -impact development
neighborhoods.
Additional Utility Easements will be required outside of the specified Right -
of -Way on a project specific basis, as determined by the utility companies.
* ACCESS MANAGEMENT: providing access to land development in such a way as to preserve safety and reasonable traffic flow
on public streets. Low, moderate and high designations are used for the level of access restrictions. A high level of access
management uses medians to restrict mid -block turns, consolidates driveways and controls the spacing of intersections. A low level of
access management limits full accessat some intersections.
August 13, 2007
Planning Commission
ADM 07-2625 Master atreet Plan Update
Agenda Item 3
Page 6 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
ALLEYS are used in conjunction with streets to provide rear access to
properties, garages, and off-street parking. Greenspace and alleys prohibit
fences and parking. They have a low level of access management.
1 a. RESIDENTIAL REAR ALLEY: ONE-WAY
Design Service Volume: < 200 vpd
Travel Lanes: One 10' lane
Parking: Not Allowed
Paved Width: 12' from outer edge of concrete strip
Right of Way: 20'
Sidewalks: None
Greenspace: Both sides of alley, min 4' wide, unencumbered
Curb cuts: Continuous access possible. No curb required
lb. RESIDENTIAL REAR ALLEY: TWO-WAY
Design Service Volume: < 200 vpd
Travel Lanes: Two 7' lanes
Parking: Not Allowed
Paved Width: 16' from outer edge of concrete strip
Right of Way: 20'
Sidewalks: None
Greenspace: Both sides of alley, min. 2' wide, unencumbered
Curb cuts: Continuous access possible. No curb required
Ic. COMMERCIAL REAR ALLEY: TWO-WAY
Design Service Volume: < 200 vpd
Travel Lanes: Two 9' lanes
Parking: Not Allowed
Paved Width: 20' from outer edge of concrete strip
Right of Way: 24'
Sidewalks: None
Greenspace: Both sides of alley, min. 2' wide, unencumbered
Curb cuts: Continuous access possible. No curb required
August 13, 2007
Planning Commission
ADM 07-2625 Master street Plan Update
Agenda Item 3
Page 7 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
RESIDENTIAL STREETS provide for the lowest level of traffic and
service. They provide access to residential property and are intended to be
used only by local traffic. A high degree of street connectivity is strongly
encouraged for easy dispersal of traffic. Residential Street block lengths
shall not exceed 600 feet. The Low -Impact Development street cross-
section will be recommended by staff only if used in conjunction with other
"green" neighborhood building practices. These practices may include, but
are not limited to, increasing energy and water efficiency, decreasing vehicle
miles traveled, avoiding floodplains, conserving wetlands and water bodies,
providing a diversity of housing types, utilizing a compact development
pattern, including certified green buildings, minimizing site disturbance
through site design and during construction, decreasing polluted stormwater
run-off, building where jobs and services are accessible by foot or transit,
and improving air quality. Residential streets have a low level of access
management.
2a. RESIDENTIAL:
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
< 300 vpd
15-20 mph
Two 9' lanes
Not Allowed
20' from face of curb
43'
Both sides of street, min. 5' wide, located in R.O.W. at
R.O.W. line
Both sides of street, min. 6' wide
2b. RESIDENTIAL LOW -IMPACT DEVELOPMENT:
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
Bio -Swale:
< 300 vpd
15-20 mph
Two 9' lanes
Not Allowed
20'
50'
One, at least 5' wide, adjoining 5' greenspace
One side of street, min. 5' wide
Both sides of street, 10' wide, tree plantings may be
permitted by the Urban Forester
August 13, 2007
Planning Commission
ADM 07-2625 Master 9jreet Plan Update
Agenda Item 3
Page 8 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
LOCAL STREETS provide for a moderate level of traffic flow and service.
They provide access to abutting land uses and provide connections to higher
order street classifications. Local Urban streets are encouraged in City
Neighborhood and Urban Center areas as depicted on the Future Land Use
Map. Local Urban Streets are also appropriate for areas that may function as
a main street for a neighborhood, offering mixed uses and a pedestrian -
friendly environment. They have a low to medium level of access
management.
3a. LOCAL:
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
3b. LOCAL URBAN:
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
< 4,000 vpd
20-25 mph
One 10' lane, One 9' lane
One 7' lane
27' from face of curb
50'
Both sides of street, min. 5' wide, located in R.O.W. at
R.O.W. line
Both sides of street, min. 6' wide
< 4,000 vpd
20-25 mph
Two 9' lanes
Two 8' lanes with bump -outs
20' from face of bump -out curb
36' entire width to face of curb
53'
Both sides of street, min. 8' wide with grated tree wells
against curb
Both sides of street, tree wells
August 13, 2007
Planning Commission
ADM 07-2625 Master Street Plan Update
Agenda Item 3
Page 9 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
COLLECTOR STREETS provide traffic circulation within residential,
commercial, and industrial areas. They collect traffic from local or
residential streets in neighborhoods and facilitate movement into the arterial
system. Connections between arterials should be direct in order to disperse
traffic throughout the city. Collector streets vary in width and function as
they respond to the context of the adjacent land uses. A minimum right-of-
way of 59 feet shall be provided where a collector is depicted on the Master
Street Plan with a 70 -foot right-of-way provided at intersections with other
collectors, minor arterials and principal arterials. The intersection right-of-
way must extend a minimum of 200 feet from the intersection. A 70 -foot
right-of-way may be required if the volume of traffic generated or predicted
warrants a continuous turning lane.
Where on -street linkages are not shown on the Fayetteville Alternative
Trails and Transportation (FATT) Plan, the paved width of 27 feet shall be
constructed, and the design should be consistent with the paved width of the
Local street cross-section. A Collector street without the on -street linkages
would have two 9 -foot lanes, a 7 -foot lane for parking, a 10 -and -a -half -foot
greenspace and a 5 -foot sidewalk on both sides of the street. All Collectors
have a moderate level of access management.
A Collector Boulevard street cross-section with a 65 -foot right-of-way is
encouraged in City Neighborhood and Urban Center areas as identified on
the Future Land Use Map. A Collector Boulevard is also encouraged for
areas that will receive or encourage significant pedestrian traffic. All
Collectors have a moderate level of access management.
4a. COLLECTOR (THROUGH):
Design Service Volume: < 4,000 vpd, < 6000 vpd with left turn bays
Desired Operating Speed: 25-30 mph
Travel Lanes: Two 14' shared motorist and cyclist lanes
Turn Lane: 12' turn bays where warranted
Bicycle Lanes: Shared with drive lane
Parking: None
Paved Width: 30' from face of curb
Right of Way: 59'
Sidewalks: Both sides of street, min. 5' wide, located in R.O.W. at
R.O.W. line
Greenspace: Both sides of street, min. 9' wide
August 13, 2007
Planning Commission
ADM 07-2625 Master Street Plan Update
Agenda Item 3
Page 10 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
4b. COLLECTOR (INTERSECTION):
Design Service Volume: < 4,000 vpd, < 6000 vpd with left turn bays
Desired Operating Speed: 25-30 mph
Travel Lanes:
Turn Lane:
Bicycle Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
Two 14' shared motorist and cyclist lanes
11' turn bays where warranted
Shared with drive lane
None
41' from face of curb
70'
Both sides of street, min. 5' wide, located at R.O.W.
Both sides of street, min. 9' wide
4c. COLLECTOR BOULEVARD:
Design Service Volume: < 4,000 vpd, < 6000 vpd with left turn bays
Desired Operating Speed: 25-30 mph
Travel Lanes: Two 10' lanes
Median/Turn Lane:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
10'
Two 8' lanes
19' from face of curb
48' entire width including median
65'
Both sides of street, min. 8' wide, with grated tree wells
against curb
None
MINOR ARTERIAL STREETS provide mobility throughout the city,
providing multiple modes of transportation within the arterial network.
Access should be limited to controlled intersections where possible. They
have a moderate level of access management.
5 MINOR ARTERIAL:
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Bicycle Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
< 12,200 vpd
35-40 mph
Four 11' lanes
5' wide, both sides of street next to curb
None
54' from face of curb
85'
Both sides of street, min. 5' wide, located in R.O.W. at
R.O.W. line
Both sides of street, min. 10' wide
August 13, 2007
Planning Commission
ADM 07-2625 Master Wreet Plan Update
Agenda Item 3
Page 11 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
PRINCIPAL ARTERIAL STREETS carry high volumes of through
traffic. They are designed as boulevards for beauty and safety. They have a
high level of access management and access should be primarily by way of
streets rather than curb cuts.
6. PRINCIPAL ARTERIAL BOULEVARD:
Design Service Volume: < 17,600 vpd
Desired Operating Speed: 40-45 mph
Travel Lanes: Four 11' lanes
Four 11' lanes at intersections
5' wide, both sides of street next to curb
10', 12' turn lane at intersections
None
28' from face of curb
66' entire width including median
97'
Both sides of street, min. 5' wide, located in R.O.W. at
R.O.W. line
Both sides of street, min. 10' wide
Bicycle Lanes:
Median:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
PRINCIPAL ARTERIAL PARKWAYS carry high volumes of through
traffic and are designed for beauty and safety. They have a high level of
access management and access should be primarily by way of streets rather
than curb cuts.
7 PRINCIPAL ARTERIAL
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Bicycle Lanes:
Median/Turn Lane:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
PARKWAY:
< 17,600 vpd
40-45 mph
Four 11' lanes
5' wide, both sides of street against curb
20' median, or 8' median with 12' turn lane
None
28' from face of curb with median
40' from face of curb with turn lane
76' entire width including median
107'
Both sides of street, min. 5' wide, located in R.O.W. at
R.O.W. line
Both sides of street, min. 10' wide
August 13, 2007
Planning Commission
ADM 07-2625 Master §treet Plan Update
Agenda Item 3
Page 12 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
H.H.O.D. (HILLTOP -HILLSIDE OVERLAY DISTRICT) STREETS
are designed with a narrow right-of-way in order to minimize grading
disturbance and tree removal, while still accommodating utility locations,
vehicular and pedestrian movements. (See example in street cross-section.)
Hillside Residential streets carry limited traffic through neighborhoods,
while Hillside Local streets collect traffic from the neighborhoods and
disperse it to minor arterials. They have a low level of access management.
8a. HILLSIDE RESIDENTIAL:
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
Utility Easements:
8b. HILLSIDE LOCAL:
Design Service Volume:
Desired Operating Speed:
Travel Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
Utility Easements:
< 500 vpd
15-20 mph
Two 9.5' lanes
Not Allowed
21' from face of curb
27'
One, at least 5' wide, abutting curb
None
Two, 15' at R.O.W.
< 4000 vpd
20-25 mph
Two 9.5' lanes
One 7' lane
27' from face of curb
33'
One, at least 5' wide, abutting curb
None
Two, 15' at R.O.W.
August 13, 2007
Planning Commission
ADM 07-2625 Master gtreet Plan Update
Agenda Item 3
Page 13 of 42
DRAFT: PLANNING COMMISSION
August 13, 2007
DOWNTOWN MASTER PLAN STREETS are specific to the Downtown
Master Plan area.
1 ST379/9
Design Service Volume:
Traffic Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
2 ST 45 8/10/9
Design Service Volume:
Traffic Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
3 ST 40 8/10/8
Design Service Volume:
Traffic Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
4 ST 63 11/11/11/11
Design Service Volume:
Traffic Lanes:
Bicycle Lanes:
Parking:
Paved Width:
Right of Way:
Sidewalks:
Greenspace:
< 300 vpd
Two 9' lanes
Not Allowed
20' from face of curb
37'
Both sides of street, min. 8' wide with grated tree wells
against curb
Both sides of street, tree wells
< 300 vpd
One 10' lane, one 9' lane
One 8' lane
28' from face of curb
45'
Both sides of street, min. 8' wide with grated tree wells
against curb
Both sides of street, tree wells
< 4,000 vpd
One 10' lane
Two 8' lanes
26' from face of curb
43'
Both sides of street, min. 8' wide with grated tree wells
against curb
Both sides of street, tree wells
<17,600
Four 11' lanes
None
None
46' from face of curb
63'
Both sides of street, min. 8' wide with grated tree wells
against curb
Both sides of street, tree wells
August 13, 2007
Planning Commission
ADM 07-2625 Master Vreet Plan Update
Agenda Item 3
Page 14 of 42