Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout121-24 RESOLUTION113 West Mountain Street
Fayetteville, AR 72701
(479) 575-8323
Resolution: 121-24
File Number: 2024-1824
MUSCO SPORTS LIGHTING, LLC. (PURCHASE AGREEMENT):
A RESOLUTION TO APPROVE THE PURCHASE OF LIGHTS, POLES, AND CONTROLLERS FROM MUSCO
SPORTS LIGHTING, LLC. IN THE TOTAL AMOUNT OF $95,051.18, PURSUANT TO A SOURCEWELL
COOPERATIVE PURCHASING CONTRACT
WHEREAS, SSI of Northwest Arkansas was recently awarded the contract to construct the new pickleball courts at
Wilson Park and lighting the existing basketball court; and
WHEREAS, Musco Sports Lighting, LLC is one of the preferred lighting providers that specializes in athletic lighting
and is a vendor in the Sourcewell system.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF FAYETTEVILLE,
ARKANSAS:
Section 1: That the City Council of the City of Fayetteville, Arkansas hereby authorizes the purchase of lights, poles,
and controllers from Musco Sports Lighting, LLC in the total amount of $95,051.18, pursuant to a Sourcewell
cooperative purchasing contract.
PASSED and APPROVED on April 16, 2024
Attest:
Page 1
CITY OF
FAYETTEVILLE
ARKANSAS
MEETING OF APRIL 16, 2024
CITY COUNCIL MEMO
TO: Mayor Jordan and City Council
THRU: Alison Jumper, Director of Parks, Natural Resources and Cultural Affairs
Susan Norton, Chief of Staff
FROM: Ted Jack, Park Planning Superintendent
SUBJECT: Lighting System for Pickleball and Basketball Courts at Wilson Park
RECOMMENDATION:
2024-1824
Recommend purchasing lights, poles, and controllers for the new pickleball courts and existing basketball court
at Wilson Park through a Sourcewell Cooperative Purchase Agreement (# 041123-MSL) contract for
$86,607.00 plus tax for a total of $95,051.18.
BACKGROUND:
SSI of Northwest Arkansas recently was awarded the contract to construct the new pickleball courts at Wilson
Park (Bid 23-46) and lighting the existing basketball court. As part of that contract, the contractor will install
new lights which are to be provided by the city. Musco is one of the preferred lighting providers that specializes
in athletic lighting, and they are a vendor in the Sourcewell system.
DISCUSSION:
Pickleball is extremely popular, and the addition of lights will greatly extend the use time of the new Pickleball
courts and the existing basketball court.
BUDGET/STAFF IMPACT:
Funds for this project come from GL Account 2250.520.9255-5806.00, Project 13001.5000.2301.
ATTACHMENTS: SRF (#3), Musco Sourcewell Submittal (#4), Musco Purchase Agreement - Musco Signed
(#5)
Mailing address:
113 W. Mountain Street www.fayetteville-ar.gov
Fayetteville, AR 72701
== City of Fayetteville, Arkansas
y 113 West Mountain Street
Fayetteville, AR 72701
(479)575-8323
- Legislation Text
File #: 2024-1824
Lighting System for Pickleball and Basketball Courts at Wilson Park
A RESOLUTION TO APPROVE THE PURCHASE OF LIGHTS, POLES, AND CONTROLLERS
FROM MUSCO SPORTS LIGHTING, LLC. IN THE TOTAL AMOUNT OF $95,051.18, PURSUANT
TO A SOURCEWELL COOPERATIVE PURCHASING CONTRACT
WHEREAS, SSI of Northwest Arkansas was recently awarded the contract to construct the new
pickleball courts at Wilson Park and lighting the existing basketball court; and
WHEREAS, Musco Sports Lighting, LLC is one of the preferred lighting providers that specializes in
athletic lighting and is a vendor in the Sourcewell system.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
FAYETTEVILLE, ARKANSAS:
Section 1: That the City Council of the City of Fayetteville, Arkansas hereby authorizes the purchase of
lights, poles, and controllers from Musco Sports Lighting, LLC in the total amount of $95,051.18,
pursuant to a Sourcewell cooperative purchasing contract.
Page 1
Ted Jack
Submitted By
City of Fayetteville Staff Review Form
2024-1824
Item ID
4/16/2024
City Council Meeting Date - Agenda Item Only
N/A for Non -Agenda Item
3/13/2024 PARKS & RECREATION (520)
Submitted Date Division / Department
Action Recommendation:
Recommend purchasing lights, poles, and controllers for the new pickleball courts and existing basketball court at
Wilson Park through a Sourcewell Cooperative Purchase Agreement (# 041123-MSL) contract for $86,607.00 plus
tax for a total of $95,051.18.
2250.520.9255-5806.00
Account Number
13001.5000.2301
Project Number
Budgeted Item? Yes
Does item have a direct cost? Yes
Is a Budget Adjustment attached? No
Purchase Order Number:
Change Order Number:
Original Contract Number:
Budget Impact:
Park Development
Fund
Wilson Park Pickleball Courts
Total Amended Budget
Expenses (Actual+Encum)
Available Budget
Item Cost
Budget Adjustment
Remaining Budget
Project Title
$ 531,325.00
$ 400,734.17
130,590,83
$ 95,051.18
35,539.65
Previous Ordinance or Resolution # 80-24
Approval Date:
V20221130
Comments: Resolution 80-24 authorized a contract with SSI of NW Arkansas to construct pickleball courts and install
lighting to be provided by the city. This is to cover purchase of the lights.
MUSCO LIGHTING PROPOSAL
PREPARED FOR:
Wilson Park Pickleball
Lighting Project
Fayetteville, AR
March 7. 2024
Project #227370
Submitted by:
Musco Sports Lighting, LLC
Attn: Jeff Annen
2107 Stewart Road
Muscatine, Iowa 52761
Toll Free: 800-756-1205
Fax: 800-374-6402
OCXDO
mus
We Make It Happen.
This information Is provided by Musco exclusively For this project. Reproduction or distribution of the enclosed documents or
Musco Sports Lighting, LLC is prohibited. M-1164-enUS-5
TABLE OF CONTENTS
0000
musco.
Wilson Park Pickleball
A. BILL OF MATERIALS
B. LIGHTING DESIGN
C. CONTROLS AND MONITORING
D. STRUCTURAL INFORMATION
E. WARRANTY
F. PRODUCT INFORMATION
C=
musco
Wilson Park Pickleball, 227370
A. BILL OF MATERIALS
0000
musco
Wilson Park Pickleball, 227370
18
Light -Structure S stemTm Total Light ControlTm TLC-LED-550 luminaires
2
30 ft galvanized steel poles
4
40 ft galvanized steel poles
6
Pre -cast concrete foundations 9,500 PSI with integrated grounding
✓
Factory wired and assembled pole top luminaire assemblies
✓
Factory wired electrical component enclosures
✓
Factory built wire harnesses with plug-in connections
Controls
2
24" x 48" Control and monitoring cabinet
✓
High/medium/low dimming
6
30-amp contactors
2
On -Off -Auto OOA switches
2
Player -activated pushbuttons with strobe LED
Warrant
✓
::]guaranteed
Musco's Constant 25TM product assurance and warranty program that eliminates
100% maintenance costs for 25 years, including labor, materials, monitoring and
light levels.
M-1911-enUS-10 Wilson Park Pickleball, Project # 227370
B. LIGHTING DESIGN
0000
musco
Wilson Park Pickleball, 227370
Wilson Park Pickleball
Fayetteville, AR, USA
Lighting System
Pole/Fixture Summary
Pole ID
Pole Height
Mtg Height
Fixture Qty Luminaire Type Circuit
BB1-BB2
30'
30'
1 3 1 TLC-LED-550 1.62 kW C
P1-P2
P4-P5
40'
40'
3 TLC-LED-550 1.62 kW A
6
18
Fixture Type Summary
Type Source Wattage Lumens L90 I L80 I L70 Quantity
TLC-LED-550 LED 5700K - 75 CRI 540W 67,000 >120,000 1 >120,000 1 >120,000 18
Single Luminaire Amperage Draw Chart
Driver Specifications
m
Line Amperage Per Luminaire
(.90 min power factor)
(max draw)
Single Phase Voltage
208
220
240
277
347
380
480
(60)
(60)
(60)
(60)
(60)
(60)
(60)
TLC-LED-550
3.2
3.0
2.8
2.4
1.9
1.8
1.4
Light Level Summary
Grid Name
Calculation Metric
Illumination
Circuits
Fixture City
Ave
Min
Max
Max/Min
Ave/Min
Basketball
Horizontal Illuminance
33.7
22
45
2.06
1.53
C
6
Basketball Spill
Horizontal Illuminance
0
0
0
0.00
C
6
Basketball Spill
Max Vertical Illuminance Metric
0
0
0
0.00
C
6
Basketball Spill -Candela
Max Candela Metric
1.50
0
12.8
0.00
C
6
Pickleball1-3
Horizontal Illuminance
41.2
30
52
1.76
1.37
A
12
Pickleball4-6
Horizontal Illuminance
42.5
32
53
1.64
1.33
A
12
From Hometown to Professional
00:O
mus
,r
We Make It Happen
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23 2023 Musco Sports Lighting, LLC.
26 38 41 40 35 28 33 35 33 24
26 37 42 39 33 30 35 35 32�24
3 33 43 44 36 37 43 40 31
31 39 42 35----'y 37 43 33 23
24 31 34 33 29 33 39 41 37 26
24 32 34 32 28 36 40 40 37 25
SCALE IN FEET 1 : 10
N
0' 10' 20'
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23
Pole location(s) (@ dimensions are relative
to 0,0 reference point(s) 0
OF
Wilson Park Pickleball
Fayetteville, AR, USA
Grid Summary I
Name Basketball
Size 105' x 60'
Spacing 10.0' x 10.0'
Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Guaranteed Average 30
Scan Average 33.72
Maximum 45
Minimum 22
Avg/Min 1.53
Guaranteed Max/Min 2.5
Max/Min 2.06
UG (adjacent pts) 1.47
CU 0.54
No. of Points 60
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 6
Total Load 3.24 kW
Guaranteed Performance: The ILLUMINATION described above
is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary
from computer -calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume ±3
nominal voltage at line side of the driver and structures
located within 3 feet (1m) of design locations.
mus
I r
We Make It Happen
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
2023 Musco Sports Lighting, LLC.
SCALE IN FEET 1 : 20
N
0' 20' 40'
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23
Pole location(s) (@ dimensions are relative
to 0,0 reference point(s) 0
Wilson Park Pickleball
Fayetteville, AR, USA
Grid Summary I
Name Pickleball 1-3
Size 112' x 62'
Spacing 10.0' x 10.0'
Height 3.0' above grade
MAINTAINED HORIZONTAL
Entire Grid
Guaranteed Average
30
Scan Average
41.15
Maximum
52
Minimum
30
Avg/Min
1.39
Guaranteed Max/Min
2.5
Max/Min
1.76
UG (adjacent pts)
1.40
CU
0.37
No. of Points
72
LUMINAIRE INFORMATION
Applied Circuits
A
No. of Luminaires
12
Total Load
6.48 kW
Guaranteed Performance: The ILLUMINATION described above
is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary
from computer -calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume ±3
nominal voltage at line side of the driver and structures
located within 3 feet (1m) of design locations.
00:O
mus
I r
We Make It Happen
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
2023 Musco Sports Lighting, LLC.
SCALE IN FEET 1 : 20
N
0' 20' 40'
Pole location(s) (@ dimensions are relative
to 0,0 reference point(s) 0
Wilson Park Pickleball
Fayetteville, AR, USA
Grid Summary I
Name Pickleball4-6
Size 112' x 62'
Spacing 10.0' x 10.0'
Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Guaranteed Average 30
Scan Average 42.46
Maximum 53
Minimum 32
Avg/Min 1.32
Guaranteed Max/Min 2.5
Max/Min 1.64
UG (adjacent pts) 1.36
CU 0.38
No. of Points 72
LUMINAIRE INFORMATION
Applied Circuits A
No. of Luminaires 12
Total Load 6.48 kW
Guaranteed Performance: The ILLUMINATION described above
is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary
from computer -calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume ±3
nominal voltage at line side of the driver and structures
located within 3 feet (1m) of design locations.
00:O
mus
I r
We Make It Happen
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23 2023 Musco Sports Lighting, LLC.
T^-
0.0 �.�
0.0
Jt
0 . 0
l
0.0
'J�
0.0
0.0 0.®.0
SCALE IN FEET 1 : 50
N
0' 50' 100'
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23
0.0
0.0 0,0
.Amin
Pole location(s) (@ dimensions are relative
to 0,0 reference point(s) 0
Wilson Park Pickleball
Fayetteville, AR, USA
Grid Summary I
Name Basketball Spill
Spacing 30.0' x 30.0'
Height 3.0' above grade
MAINTAINED HORIZONTAL
Grid
Scan Average 0.0000
Maximum 0.00
Minimum 0.00
CU 0.00
No. of Points 43
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 6
Total Load 3.24 kW
Guaranteed Performance: The ILLUMINATION described above
is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary
from computer -calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume ±3
nominal voltage at line side of the driver and structures
located within 3 feet (1m) of design locations.
00:O
mus
I r
We Make It Happen
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
2023 Musco Sports Lighting, LLC.
T--
0.0 �.�
0.0
Jt
0 . 0
l
0.0
'J�
0.0
0.0 0.®.0
SCALE IN FEET 1 : 50
N
0' 50' 100'
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23
0.0
0.0 0,0
Pole location(s) (@ dimensions are relative
to 0,0 reference point(s) 0
Wilson Park Pickleball
Fayetteville, AR, USA
Grid Summary I
Name Basketball Spill
Spacing 30.0' x 30.0'
Height 3.0' above grade
MAINTAINED MAX VERTICAL
Grid
Scan Average 0.0003
Maximum 0.00
Minimum 0.00
CU 0.00
No. of Points 43
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 6
Total Load 3.24 kW
Guaranteed Performance: The ILLUMINATION described above
is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary
from computer -calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume ±3
nominal voltage at line side of the driver and structures
located within 3 feet (1m) of design locations.
00:O
mus
I r
We Make It Happen
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
2023 Musco Sports Lighting, LLC.
Pole
Luminaires
CITY LOCATION
SIZE
GRADE
MOUNTING
LUMINAIRE TYPE QTY/POLE THIS OTHER
ELEVATION
HEIGHT
GRID GRIDS
2 BB1-BB2
30'
1 -
30'
TLC-LED-550 1 3 1 3 0
SCALE IN FEET 1 : 50
N
0' 50' 100'
Pole location(s) (@ dimensions are relative
to 0,0 reference point(s) 0
Wilson Park Pickleball
Fayetteville, AR, USA
Grid Summary I
Name Basketball Spill -Candela
Spacing 30.0' x 30.0'
Height 5.0' above grade
Illumination
MAINTAINED CANDELA (PER FIXTURE)
Entire Grid
Scan Average 1.4978
Maximum 12.78
Minimum 0.00
CU 0.00
No. of Points 43
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 6
Total Load 3.24 kW
Guaranteed Performance: The ILLUMINATION described above
is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary
from computer -calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume ±3
nominal voltage at line side of the driver and structures
located within 3 feet (1m) of design locations.
00:O
mus
I r
We Make It Happen
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23 2023 Musco Sports Lighting, LLC.
SCALE IN FEET 1 : 50
N
0' 50' 100'
Pole location(s) G dimensions are relative
to 0,0 reference point(s) 0
Wilson Park Pickleball
Fayetteville, AR, USA
INCLUDES:
Basketball
Pickleball 1-3
Pickleball 4-6
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures
located within 3 feet (1m) of design locations.
Single Luminaire Amperalie Draw CAP
Driver Specifications Line Amperage Per Luminaire
(.90 min power factor) (max draw)
208 110 140 117 347 380 480
Single Phase Voltage (60) (60) (60) (60) (60) (60) (60)
TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4
00:O
mus
r
We Make It Happen
ENGINEERED DESIGN By: Mitchell Thys • File #227370D • 29-Sep-23
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981,
2023 Musco Sports Lighting, LLC.
C. CONTROLS AND MONITORING
0000
musco.
Wilson Park Pickleball, 227370
Project Information
.ate I
Control System ��
Control System ID: _`
Control System Type: Control -Link tb\trol and MAMring
�► System
Communication Type: Nl�l •\11WerLine-ST
Power Requirements
Control cabinet(s): 15
Control voltage (phase to neutrall 120/60
VA loading - Inrush �X
VA loading -Sealed
Lighting Circuits:
Voltage/Hertz/Ph1j 3
Important Notes:
Project Name: Wilson Park Pickleball I Project #: 227370
Control System ID: 1 of 2
Distribution Panel Location/ID: Pickleball
ject Notes:
This field has a pushbutton/strobe assembly
1553.0 Control and monitoring cabinet -
180.0 primary
240/60/1
24 X 48
1. Please confirm that the lighting circuit voltage listed above is accurate for this facility. This is the voltage/phase being
connected and utilized at each lighting pole's electrical components enclosure disconnect. Inaccurate voltage/phase can
result in additional costs and delays. Contact your Musco sales representative to confirm this item.
2. Ina 3 phase design, all 3 phases are to be run to each pole location. Musco's single phase luminaires come pre -wired to utilize
all 3 phases across the entire facility.
3. One contactor is required for each circuit at each pole location. Contactors are 3 pole and 100% rated for the published
continuous load.
4. If the lighting system will be fed from more than one distribution location, additional equipment maybe required. Contact
your Musco sales representative.
5. Size overcurrent devices using the full load amps column of the Circuit Summary by Switch chart (Minimum power factor is
0.9). Size conduit per code unless otherwise specified as larger to allow for harness connectors.
6. Avoid use of in -ground junction/pull boxes when possible. If used, all wire connectors must be UL listed for Wet Locations to
prevent leakage current.
7. Control power wiring must be in separate conduit from line or load power wiring. Communication cables must be in separate
conduit from any power wiring.
8. Refer to Installation Instructions for more details on equipment information and the installation requirements.
C000
MUSCo,
Sales Representative: Nate McDonald I Project Engineer: Mitchell Thys I Scan: 227370E I Document ID: 227370P1 V2-0727133943
Page 1 of 6 -- 27-July-2023
Project Name: Wilson Park Pickleball I Project #: 227370
Control System ID: 1 of 2
Distribution Panel Location/ID: Pickleball
Equipment Layout and Connection Details
Control cabinet location
2a O) LIJ
p jl
I DO I I
jl
1a
I �I
II
1 a Line power to contactors, and equipment grounding conductor. Requires one
circuit per contactor, size wiring per load and voltage drop.
1 b Load power from contactors, and equipment grounding conductor. Requires
one circuit per contactor, size wiring per load and voltage drop.
2a Control power with equipment ground to control cabinet. Requires dedicated
20 A circuit. Provide transformer if control voltage not present.
Lighting system
1 Control and monitoring cabinet -
primary
COOO
Imusco,
Sales Representative: Nate McDonald I Project Engineer: Mitchell Thys I Scan: 227370E I Document ID: 227370P1 V2-0727133943
Page 2 of 6 -- 27-July-2023
Circuit Summary
Pickleball
Control Module ID:1
1
Project Name: Wilson Park Pickleball I Project #: 227370
Control System ID: 1 of 2
Distribution Panel Location/ID: Pickleball
Lighting Circuit Voltage: 240/60/1
1 Pickleball P1 3 8.31 30 1 C1
Pickleball P2 3 8.31 30 1 C2
Pickleball P4 3 8.31 30 1 0
Pickleball P5 3 8.31 30 1 C4
Sales Representative: Nate McDonald I Project Engineer: Mitchell Thys I Scan: 227370E I Document ID: 227370P1 V2-0727133943
COOOSCE lighting@musco.com
Page 3 of 6 -- 27-July-2023
Project Information
.ate I
Control System ��
Control System ID: _`
Control System Type: Control -Link tb\trol and MAMring
�► System
Communication Type: Nl�l •\11WerLine-ST
Power Requirements
Control cabinet(s): 15
Control voltage (phase to neutrall 120/60
VA loading - Inrush �X
VA loading -Sealed
Lighting Circuits:
Voltage/Hertz/Ph1j 3
Important Notes:
Project Name: Wilson Park Pickleball I Project #: 227370
Control System ID: 2 of 2
Distribution Panel Location/ID: Basketball
ject Notes:
This field has a pushbutton/strobe assembly
1063.0 Control and monitoring cabinet -
128.0 primary
240/60/1
24 X 48
1. Please confirm that the lighting circuit voltage listed above is accurate for this facility. This is the voltage/phase being
connected and utilized at each lighting pole's electrical components enclosure disconnect. Inaccurate voltage/phase can
result in additional costs and delays. Contact your Musco sales representative to confirm this item.
2. Ina 3 phase design, all 3 phases are to be run to each pole location. Musco's single phase luminaires come pre -wired to utilize
all 3 phases across the entire facility.
3. One contactor is required for each circuit at each pole location. Contactors are 3 pole and 100% rated for the published
continuous load.
4. If the lighting system will be fed from more than one distribution location, additional equipment maybe required. Contact
your Musco sales representative.
5. Size overcurrent devices using the full load amps column of the Circuit Summary by Switch chart (Minimum power factor is
0.9). Size conduit per code unless otherwise specified as larger to allow for harness connectors.
6. Avoid use of in -ground junction/pull boxes when possible. If used, all wire connectors must be UL listed for Wet Locations to
prevent leakage current.
7. Control power wiring must be in separate conduit from line or load power wiring. Communication cables must be in separate
conduit from any power wiring.
8. Refer to Installation Instructions for more details on equipment information and the installation requirements.
C000
MUSCo,
Sales Representative: Nate McDonald I Project Engineer: Mitchell Thys I Scan: 227370E I Document ID: 227370P1 V2-0727133943
Page 4 of 6 -- 27-July-2023
Project Name: Wilson Park Pickleball I Project #: 227370
Control System ID: 2 of 2
Distribution Panel Location/ID: Basketball
Equipment Layout and Connection Details
Control cabinet location
2a O) LIJ
p jl
I DO I I
jl
1a
I �I
II
1 a Line power to contactors, and equipment grounding conductor. Requires one
circuit per contactor, size wiring per load and voltage drop.
1 b Load power from contactors, and equipment grounding conductor. Requires
one circuit per contactor, size wiring per load and voltage drop.
2a Control power with equipment ground to control cabinet. Requires dedicated
20 A circuit. Provide transformer if control voltage not present.
Lighting system
1 Control and monitoring cabinet -
primary
COOO
Imusco,
Sales Representative: Nate McDonald I Project Engineer: Mitchell Thys I Scan: 227370E I Document ID: 227370P1 V2-0727133943
Page 5 of 6 -- 27-July-2023
Circuit Summary
Basketball
Control Module ID: 2
Project Name: Wilson Park Pickleball I Project #: 227370
Control System ID: 2 of 2
Distribution Panel Location/ID: Basketball
Lighting Circuit Voltage: 240/60/1
1 Basketball BB1 3 8.31 30 2 C1
Basketball BB2 3 8.31 30 2 C2
COOO
musco.
Sales Representative: Nate McDonald I Project Engineer: Mitchell Thys I Scan: 227370E I Document ID: 227370P1 V2-0727133943
Page 6 of 6 -- 27-July-2023
D. STRUCTURAL INFORMATION
0000
musco
Wilson Park Pickleball, 227370
LIGHT STRUCTURE
STEEL POLE BY
MUSCO LIGHTING
(SEE POLE ID)
z
O
Ul U �
w
cr m
a i-
w
m U
Q W
[o w
I- a
Q w
U w
w
Of ,
IZ
0
N
►•A
POLE FOUNDATION SCHEDULE
POLE
DESIGNATION
FORCES (1.)
DRILLED PIER
MOMENT (M)
FT-LBS
SHEAR (V)
LBS
VERTICAL (P)
LBS
DIAMETER
INCHES
EMBEDMENT
DEPTH
CONCRETE
BACKFILL
YD3 (2.)
BB1, BB2
5,973
317
464
30
8'-0"
1.0
P1, P2, P4, P5
11,497
449
528
30
8'-0"
1.0
1. ASD LOAD COMBINATION D + 0.6W.
VERTICAL FORCE IS WEIGHT OF DRESSED POLE (DOES NOT INCLUDE PRECAST BASE WEIGHT).
2. MINIMUM CONCRETE BACKFILL VOLUME, SITE CONDITIONS MAY REQUIRE ADDITIONAL BACKFILL.
SOIL BACKFILL,
SEE NOTE BELOW
= w
IL
w
P
_
LIGHT STRUCTURE
Z U)
PRECAST BASE BY
Z
c LD
MUSCO LIGHTING
(SEE POLE ID)
m Q
w0
Z
O
a LL
a.
CONCRETE
BACKFILL
w p
J
J W
a
o w
�
f
UNDISTURBED,
IN -SITU SOIL
PRECAST BASE IDENTIFICATION
PRECAST
BASE TYPE
PRECAST
BASE WEIGHT
PRECAST
BASE LENGTH
PROJECTION
ABOVE GRADE
STANDARDIm
EMBEDMENT
1 B
920 LBS
15'-2"
7'-2"
8'-0"
POLE IDENTIFICATION
FIXTURE
FIXTURE AND
POLE
POLE
PRECAST
CONFIGURATION
ACCESSORIES
DESIGNATION
TYPE
BASE TYPE
(FIX. PER XARM)
EPA (FT )
BB1, BB2
LSS30A
113
3 (3)
3.9
P1, P2, P4, P5
LSS40A
113
1 3 (3)
3.9
I DESIGN NOTES I
DESIGN PARAMETERS:
WIND: V = 110 MPH, Vasd = 85 MPH ( EXPOSURE C, RISK CATEGORY II) PER
INTERNATIONAL BUILDING CODE, 2021 EDITION (ASCE 7-16). DESIGN WIND PARAMETERS
ARE AS NOTED, ACTUAL EXPOSURE MUST BE VERIFIED FOR THE SITE BY THE PROPER
GOVERNING OFFICIAL.
GEOTECHNICAL PARAMETERS:
ALLOWABLE END BEARING SOIL PRESSURE: 1,500 PSF OR SKIN FRICTION: 250 PSF
ALLOWABLE LATERAL SOIL BEARING PRESSURE:
100 PSF/FT (GRADE TO-2'-0"); 200 PSF/FT (BELOW-2'-0")
IN ACCORDANCE WITH THE 2021 EDITION OF THE INTERNATIONAL BUILDING CODE,
CHAPTER 18. SEE TABLE 1806.2, SOIL MATERIAL CLASS 5 & SECTION 1806.3.4.
DESIGN SOIL PARAMETERS ARE AS NOTED. ACTUAL ALLOWABLE SOIL PARAMETERS
MUST BE VERIFIED ON SITE.
A GEOTECHNICAL ENGINEER OR REPRESENTATIVE OF IS RECOMMENDED (NOT
REQUIRED) TO BE AVAILABLE AT THE TIME OF THE FOUNDATION INSTALLATION TO
VERIFY THE SOIL DESIGN PARAMETERS AND TO PROVIDE ASSISTANCE IF ANY
PROBLEMS ARISE IN FOUNDATION INSTALLATION.
ENCOUNTERING SOIL FORMATIONS THAT WILL REQUIRE SPECIAL DESIGN
CONSIDERATIONS OR EXCAVATION PROCEDURES MAY OCCUR. POLE FOUNDATIONS
WILL NEED TO BE ANALYZED ACCORDING TO THE SOIL CONDITIONS THAT EXIST. IF
ANY DISCREPANCIES OR INCONSISTENCIES ARISE, NOTIFY THE ENGINEER OF SUCH
DISCREPANCIES. FOUNDATIONS WILL THEN BE REVISED ACCORDINGLY. REVISIONS
WILL BE ANALYZED PER RECOMMENDATIONS DIRECTED BY A REGISTERED ENGINEER.
ALL EXCAVATIONS MUST BE FREE OF LOOSE SOIL AND DEBRIS PRIOR TO
FOUNDATION INSTALLATION AND CONCRETE BACKFILL PLACEMENT. TEMPORARY
CASINGS OR DRILLERS SLURRY MAY BE USED TO STABILIZE THE EXCAVATION DURING
INSTALLATION. CASINGS MUST BE REMOVED DURING CONCRETE BACKFILL PLACEMENT.
CONCRETE BACKFILL MUST BE PLACED WITH A TREMIE WHEN SLURRY OR WATER IS
PRESENT WITHIN THE EXCAVATION.
CONTRACTOR MUST BE FAMILIAR WITH THE COMPLETE SOIL INVESTIGATION REPORT
AND BORINGS, AND CONTACT THE GEOTECHNICAL FIRM (IF NECESSARY) TO
UNDERSTAND THE SOIL CONDITIONS AND THE POSSIBILITY OF GROUND WATER
PUMPING AND EXCAVATION STABILIZATION OR BRACING DURING PRECAST BASE
INSTALLATION AND PLACEMENT OF CONCRETE BACKFILL.
CONCRETE:
CONCRETE SHALL BE AIR -ENTRAINED AND HAVE A MINIMUM COMPRESSIVE DESIGN
STRENGTH AT 28 DAYS OF 3,000 PSI. 3,000 PSI CONCRETE SPECIFIED FOR EARLY POLE
ERECTION, ACTUAL REQUIRED MINIMUM ALLOWABLE CONCRETE STRENGTH IS
1,000 PSI. ALL PIERS AND CONCRETE BACKFILL MUST BEAR ON AND AGAINST FIRM
UNDISTURBED SOIL.
GENERAL NOTES:
FIXTURES MUST BE LOCATED TO MAINTAIN 10'-0" MINIMUM HORIZONTAL CLEARANCE
FROM ANY OBSTRUCTION. ENGINEER MUST BE NOTIFIED IF FOUNDATIONS ARE NEAR
ANY RETAINING WALLS OR WITHIN / NEAR ANY SLOPES STEEPER THAN 3H : 1V. POLES,
FIXTURES, PRECAST BASES, ELECTRICAL ITEMS AND INSTALLATION PER MUSCO
LIGHTING.
DRILLED PIER DIAMETER _
(SEE POLE FNDTN. SCH.) ����111111111/�,,
OF AUTO'''%,� ,/`ARKANSAS �1
POLE FOUNDATION ELEV. P.
C.1 .
SEPC 027.
= `� LICENSED
SCALE: NOT TO SCALE
U ; OF IOWA ; _ PROFESSIONAL
SOIL BACKFILL NOTE: k 1
THE TOP TWO FEET OF ANNULUS SHALL BE BACKFILLED WITH No. 977 ENGINEER 1,
SOIL, WITH A CLASSIFICATION OF CLASS 5 (TABLE 1806.2) OR ��
BETTER. COMPACTION, 95% FOR COHESIVE SOIL AND 98% 'i ��O 3
FOR A
PROCTOR E SITOING NLES
SS ILL BASED UPON STANDARD ''gRKANSPsZ
����`��� �,; p` /iaL Q
III /�/
Y
Z_
J
Q
~
W
J
m
�
J
J
OJUW
F—
J
V
J
w
Q
F_
Q
LL
r
V)
0 W
® 3n
w�
allo
® ® u4
oN00
ii0o
0
� Y 00
C,
a�
0
U
00 -It
m IV
c" m
0 Lo
LU
j O v U)
co �
LL
0 ��w°
cn0mz
U 0 _j
Z
U = w
Z W Z J
W woa
taw
z
O
H
Q
0
z o
Z1 C)g LL c)
w N
w
z Q U) �
w w w Z
a J
ind U) z cA
PROJECT NUMBER
227370
DATE
17 JANUARY 2024
DRAWING NUMBER
C1
OF ONE
E. WARRANTY
0000
musco
Wilson Park Pickleball, 227370
0000
mus o
;z7ff
Wo "mmm
25-Year Product Assurance & Warranty Program
Project name: Wilson Park PICkleball Project number: 227370
owner: City of Fayetteville city, Fayetteville state:AR
Covered product(,,): Light -Structure System TM with TLC for LED TM technology
Date issued: Date of Shipment Expiration: Date of Shipment + 25 Years
Musco Sports Lighting, LLC will provide all materials and labor to maintain operation of your lighting system to
original design criteria for 25 years. Musco products and services are guaranteed to perform on your project as
detailed in this document.
Light Performance
Specified illumination levels will be maintained and are marked as guaranteed in the Musco Illumination Summary.
Individual luminaire outages that occur during the warranty and maintenance period are repaired when the usage of any
field is materially impacted.
Spill Light Control
If specified, spill light levels at identified locations are guaranteed to be controlled to the maximum values provided in the
Musco Illumination Summary.
Energy Consumption
Total average kW consumption for your lighting system is guaranteed to be not more than the total load shown in the
Musco Illumination Summary.
Monitoring, Maintenance, and Control Services
Musco shall monitor the performance of your lighting system, including on/off status, hours of usage, and luminaire
outages. If outages that affect playability are detected, Musco will contact you and proactively dispatch technicians.
On -off control of your lighting system is provided via an easy -to -use web site scheduling system, smartphone app, phone,
email, or fax. Our trained Control -Link CentralTM service center staff is available toll -free 24/7. Regular usage reports are
always available on Control -Link Central's web site.
Structural Integrity
Your project has been designed to IBC, 2021, 110mph, Exposure C
Structural integrity of equipment manufactured by Musco is guaranteed.
Musco has a team of people to ensure fulfillment of our product and services warranty and maintains financial
reserves dedicated to support our fulfillment of this warranty. Please keep this document as your signed
contract guaranteeing comprehensive service for the 25 year period.
- Page 1 of 2 -
©2005, 2019 Musco Sports Lighting, LLC M-1291-enUS-11
W). "_,� R", 07 W, I- r�Wy I
"M
25-Year Product Assurance & Warranty Program
Terms and Conditions
Service under this Contract is provided by Musco Sports Lighting, LLC ("Musco") or
an authorized servicer approved by Musco. Services performed under this Contract
shall consist of furnishing labor and parts necessary to restore the operation of the
Covered Product(s) to original design criteria provided such service is necessitated
by failure of the Covered Product(s) during normal usage. This Contract covers
Product(s) consisting of Musco's Total Light Control — TLC for LED® with
Control -Link® and any additional Musco manufactured product as listed on page 1.
"We", "us," and "our' mean Musco. "You" and "your" mean the purchaser of the
Covered Product(s). No one has the authority to change this Contract without the
prior written approval of Musco. Musco shall not assume responsibility for their
agents or assignees other than as described below. If there is a conflict between the
terms of this Contract and information communicated either orally or in writing by one
or more of our employees or agents, this Contract shall control.
Additional Provisions
Availability of Service: Control -Link Central TM operators shall be available
24/7 via web site, phone, fax, or email. Maintenance service specialists shall
be available 8AM to 5PM Central Time, and services shall be rendered during
these same hours in your local time zone, Monday through Friday (with the
exception of national holidays). Hours of operation are subject to change without
notice to you. Musco will exercise all reasonable efforts to perform service under
this Contract, but will not be responsible for delays or failure in performing such
services caused by adverse weather conditions, acts of any government, failure
of transportation, accidents, riots, war, labor actions or strikes or other causes
beyond its control.
2. Determination of Repairs: Musco will utilize the field monitoring system and
any information provided by the customer to determine when the usage of the
field is materially impacted. From this information, Musco will determine needed
repair and/or replacement of Covered Product(s) and parts. Repair will be with
Product(s) of like kind and quality.
3. Your Requirements Under this Contract: You must meet all electrical
and installation requirements as specified by the manufacturer. In addition,
you promise and assure: full cooperation with Musco, Musco's technicians
and authorized servicers during telephone diagnosis and repair of the
Covered Product(s); reasonable accessibility of the Covered Product(s); a
nonthreatening and safe environment for service.
You agree to check fuses and to replace fuses as needed. Musco provides
spare fuses in the lowest alpha -numeric numbered enclosure. Musco will
replenish spare fuses used.
You agree to keep your control system online. This means keeping the required
control voltage to the control system at all times. Any deviation from this practice
must be discussed with Musco's Warranty Department.
4. Service Limitations — This Contract does not cover: Maintenance, repair,
or replacement necessitated by loss or damage resulting from any external
causes such as, but not limited to, theft, environmental conditions, negligence,
misuse, abuse, improper electrical/power supply, unauthorized repairs by third
parties, attachments, damage to cabinetry, equipment modifications, vandalism,
animal or insect infestation, physical damage to Covered Product(s) parts or
components, failure of existing structures, supporting electrical systems or
any non-Musco equipment, or acts of God/nature (including, but not limited to:
earthquake, flood, tornadoes, typhoons, hurricanes, or lightning).
5. Contract Limitations:
a. EXCLUSIONS FROM COVERAGE: IN NO EVENT WILL MUSCO BE LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES WHICH INCLUDE, BUT ARE NOT LIMITED TO, ANY DELAY IN
RENDERING SERVICE OR LOSS OF USE DURING THE REPAIR PERIOD
OF THE COVERED PRODUCT(S) OR WHILE OTHERWISE AWAITING
PARTS.
b. Limitation of Liability: To the extent permitted by applicable law, the
liability of Musco, if any, for any allegedly defective Covered Product(s)
or components shall be limited to repair or replacement of the Covered
Product(s) or components at Musco's option. THIS CONTRACT IS YOUR
SOLE EXPRESS WARRANTY WITH RESPECT TO THE COVERED
PRODUCT(S). ALL IMPLIED WARRANTIES WITH RESPECT TO
THE COVERED PRODUCT(S) INCLUDING, BUT NOT LIMITED TO,
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, ARE HEREBY EXPRESSLY EXCLUDED.
c. For the purposes of and by your acceptance of this Contract you acknowledge
and agree that if a surety bond ("Bond") is provided the warranty and/or
maintenance guarantee provided for in this Contract and any corresponding
liability on behalf of the issuing surety under the Bond is limited to the first
twelve (12) months of said warranty and/or maintenance guarantee coverage
period. Any warranty and/or guarantee coverage period in excess of said
initial 12 month period does not fall within the scope of the Bond and shall be
the sole responsibility of Musco.
d. Musco requires reasonable access for a crane or man lift equipment to
service the lighting system. Musco will not be responsible for damage from
operating the vehicle on the property when the equipment is operated in the
prescribed manner over the designated access route.
e. Obsolescence or Environmental Restrictions: If during any maintenance
or other work performed under this Warranty, any of the parts of the
Covered Product(s) are found to be either obsolete, no longer available, or
prohibited by any state of federal agency, Musco shall replace said parts with
comparable parts and materials with equal operating characteristics solely at
Musco's discretion. The cost of replacement of any obsolete cellular related
technology shall be borne by you. Prior to completing any such work, Musco
shall notify you of the cost (if any) you will incur in the replacement of such
parts under this section.
6. Transfer and Assignment: Except to owners, you shall not have the right to
assign or otherwise transfer your rights and obligations under this Contract
except with the prior written consent of Musco; however, a successor in interest
by merger, operation of law, assignment or purchase or otherwise of your entire
business shall acquire all of your interests under this Contract.
7. Governing Law: Unless otherwise governed by applicable state law, the Contract
shall be interpreted and enforced according to the laws of the State of Iowa.
8. Subrogation: In the event Musco repairs or replaces any Covered Product(s),
parts or components due to any defect for which the manufacturer or its agents
or suppliers may be legally responsible, you agree to assign your rights of
recovery to Musco. You will be reimbursed for any reasonable costs and
expenses you may incur in connection with the assignment of your rights. You
will be made whole before Musco retains any amounts it may recover.
Signature:
- Page 2of2-
Vice President of Sales
02005, 2019 Musco Sports Lighting, LLC M-1291-enU8-11
0000
musco
F. PRODUCT INFORMATION
Wilson Park Pickleball, 227370
TLC for LED°
5 Easy Pieces T1W
Complete System from
Foundation to Poletop
Factory wired, aimed, and tested
Fast, trouble -free installation
Comprehensive corrosion package
Integrated lightning ground
OC=
musco
FS I
n
TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
02015, 2019 Musco Sports Lighting, LLC • U.S. and foreign patent(s) issued and pending. • M-3301-en04-1
Datasheet: Light -Structure SystemTM MENEM
TLC for LED' - Precast Concrete Base
5 Easy Pieces -
Overview
The precast concrete base is set directly into the ground and
backfilled with concrete. The base includes an integrated
lightning ground system.
Features
Base
• Set pole on base in 24 hours
• Tapered upper section for slip -fit steel pole
• Access holes for wire entry
• Epoxy -coated ends prevent water intrusion
• Lifting hole accepts load -rated steel rod provided
by Musco
Integrated Lightning Ground System
F1
• Complies with NFPA 780, UL 96A, and EN 62305 standards
when installed per Musco installation instructions
D1, • UL Listed, Class II Lightning Protection,
file number E337467
• Tested up to 100 kA by independent laboratory
• Steel pole interfaces with integrated grounding system by
means of the pole grounding connector
• 2/0 AWG (crossectional area of 67.4 mm2) grounding
electrode conductor
• Concrete -encased grounding electrode, 20 feet (6.1 m)
total length,'/2 inch (12.7 mm) diameter
Technical Specifications
Base dimensions vary. For measurements refer to project -specific
!,I
Foundation and Pole Assembly drawing.
Construction
• Spun concrete construction
• Prestressed steel vertical strands and coil spiral for
strength throughout base
• Minimum design strength is 9500 Win (65.5 MPa) at 28 days
• Meets ASTM C1804 design requirements
I
Quality Assurance Tests
• 28-day compressive strength
• Bending moment capacity
• Grounding system continuity
0000 TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
©2012, 2019 Musco Sports Lighting, LLC • U.S. patents issued. M-2215-en04-3
musco
1
TLC for LED' - Precast Concrete Base
Wireway
Pole ID
Tapered upper
section for
slip -fit steel pole
Lifting hole
Grounding
electrode
conductor
Compacted
dirt fill
top 2ft(0.6m)'
Concrete backfill*
Pole grounding
connector
Steel
reinforcement
Handhole
Conduit
adapter plate
Wire access hole
Integrated
grounding electrode
'Standard pier foundation shown. Foundation and/or backfill may vary per alternate
foundation design.
5 Easy Pieces"
TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
02012, 2019 Musco Sports Lighting, LLC • U.S. patents issued. • M-2215-en04-3
Datasheet: Light -Structure SystemTM NUMEN
TLC for LED' - Galvanized Steel Pole
5 Easy Pieces -
Overview
The galvanized steel pole is designed to slip -fit together with
the precast concrete base and the poletop luminaire assembly.
i
Features
• Slip -fit connection allows pole assembly with come-alongs
• Built-in hardware for attaching electrical components
enclosure
• Wire access from inside the pole (no exposed wiring or
o conduit)
• Shipped in sections for easier handling
• Labeled with pole identification for location on field
Technical Specifications
Pole dimensions vary. For measurements refer to project
specific pole configuration drawing.
Construction
• Pole designs comply with all major building codes
• High strength, low alloy, tapered, round steel pole
• Hot -dip galvanizing inside and outside after fabrication
meets ASTM-Al23 and EN 1461 standards
• Conforms to AASHTO stress standards and BS EN 40-3-1
• Grounding lug —rated for aluminum (AL) or
copper (CLI) wiring
• Pole shipped in sections
• Stainless steel fasteners passivated and coated
• Material certifications are available
Quality Assurance Tests
• Bending stress
• Minimum galvanizing thickness
• Straightness measurement
`/`J`JO TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
©2005, 2019 Musco Sports Lighting, LLC M-2216-en04-3
musco
1
TLC for LED' - Galvanized Steel Pole
Weld mark to identify
field side orientation
Wire harness strain relief
provided on poles 80 ft (24.5 m)
and taller per NEC
Electrical
components enclosure
attachment bracket
Electrical components
enclosure hub with stainless
steel screw threads
Slip -fit attachment to
precast concrete base
Weld mark to identify
field side orientation
I;
"A
Jacking ear
Wire access handhole
Grounding lug
(inside handhole)
5 Easy Pieces"
O`= TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
02005, 2019 Musco Sports Lighting, LLC • M-2216-en04-3
musco
Datasheet: Light -Structure SystemTMENUEN
5 Easy Pieces -
TLC for LED' - Electrical Components Enclosure
Overview
The electrical components enclosure contains all necessary
equipment to operate luminaires. Built-in mounting hardware
\
allows for easy attachment to the galvanized steel pole. Quick
connect plugs fasten to the wire harness.
Features
Factory -built and tested as a unit
• Quick connect plug for easy field wiring
°
I
• Mounted 10 ft (3 m) above grade for servicing with ladder
Labeled with pole identification and electrical information
Drivers individually fused and spare fuses supplied
Wire access from inside the pole (no exposed wiring
I;
I
or conduit)
• Disconnect per circuit
Technical Specifications
For amperage draws and circuitry refer to project
specific document.
Construction
0.08 inch (2 mm) thick, powder -coated aluminum
• Enclosure ratings: NEMA 3R, IP54
• Designed to operate in up to 50' C (122' F) ambient
temperature
• Full length stainless steel hinge
00
• All stainless steel fasteners passivated and coated
i
i
• Meets touchsafe standards
• Up to four drivers per enclosure
l
• Approximate weight 65 lb (29 kg)
r1
• Lower enclosure size 14.25 in (362 mm) wide
�J
x 8 in (203 mm) deep x 52.5 in (1334 mm) high
r
• Upper enclosure size 14.25 in (362 mm) wide
(
x 8 in (203 mm) deep x 40.5 in (1029 mm) high
°
Quality Assurance Tests
• Grounding continuity
• High potential dielectric withstand
• Full functionality test
VIVO
musco
TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
©2015, 2023 Musco Sports Lighting, LLC - ECE 9 M-2217-en04-4
10
TLC for LED' - Electrical Components Enclosure
5 Easy Pieces"
Controller (if present)
Wiring
schematics
Driver
Spare fuses
Fuses
Pole alignment
beam switch
Ground bar (AL,CU)*
Surge protection, rated 50 kA
Powerline communication
(or wireless communication) module
(if present)
Disconnect (CU only)*
Terminal blocks
* Aluminum (AL)
Copper(CU)
0000 TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
02015, 2023 Musco Sports Lighting, LLC - ECE 9 - M-2217-en04-4
Musco
TLC for LED° -Wire Harness 5 Easy Pieces"
Overview
The factory -built wire harness connects the
electrical components enclosure to the poletop
luminaire assembly.
J Features
• Quick connect plugs for easy field wiring
• Factory -assembled support grip alleviates
strain on connections
• Spiral wound cable eliminates slippage
• Protective sleeve prevents wire damage
• All internal wiring, no exposed wires
• Labels identify pole and luminaires
00 Technical Specifications
i
i .40 Construction
##1 0.0 Spiral wound, wrapped cable, 14 AWG
(cross -sectional area of 2.08 mm2) copper wire
• Integral cable support grip
• Two wires per driver
• Each harness supports up to four drivers
• Multiple top connectors may be present if
required for number of luminaires
Quality Assurance Tests
• Connector/load resistance
• High potential dielectric withstand
• Grounding continuity
• Termination crimp
OC= TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
02005, 2019 Musco Sports Lighting, LLC M-2218-en04-3
musco.
1
TLC for LED' - Wire Harness
Top quick connector
Wire tie
Top cable support grip
Spiral wound cable consisting
of 14 AWG (cross -sectional
area of 2.08 mm2) copper wire
Mid -point cable support grip
for poles 80 ft (24.5 m) and taller
Flexible protective sleeve
Bottom quick connector
B
quick
5 Easy Pieces"
arness top
,onnector
support grip
iap hook
support grip
iap hook
uired)
iure harness
,onnector
arness bottom
,onnector
OC= TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
m2005, 2019 Musco Sports Lighting, LLC - M-2218-en04-3
musco,
MEMMUDatasheet: Light -Structure SystemTM
TLC for LED' — Poletop Luminaire Assembly, Weld On 5 Easy Pieces -
Overview
The factory -aimed poletop luminaire assembly is the upper
section of the pole and slip -fits together with the galvanized
steel pole.
Features
• Each luminaire is factory -built, tested, and ships as a unit
• Luminaires are factory -aimed to two -tenths degree
of accuracy
• Luminaire mounts and connects in a single step
• Slip -fit connection allows assembly with come-alongs
• All luminaires are factory -wired to a quick connect
harness for easy installation
• Labels identify pole and luminaire location
• No exposed wiring or conduit
• Factory -set pole alignment beam allows easy
field alignment
Technical Specifications
Construction
• Crossarms and pole shaft hot -dip galvanizing inside
and outside after fabrication meets ASTM-Al23 and
EN 1461 standards
• All aluminum components are powder -coated or
anodized to mil-A-8625F and BS 5599
• Luminaire and knuckle are powder -coated die-cast
aluminum
• All stainless steel fasteners are passivated and coated
• Crossarms are constructed of rectangular steel tubing
• Polecap is attached with stainless steel lanyard and
securing bolt
Quality Assurance Tests
• Galvanizing thickness
• High potential dielectric withstand
• Electrical continuity
TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
02015, 2019 Musco Sports Lighting, LLC U.S. and foreign patent(s) issued and pending. M-2219-en04-3
5 Easy Pieces"
TLC for LED' - Poletop Luminaire Assembly, Weld On
Crossarm
Die-cast aluminum
luminaire mounting plate
Die-cast aluminum knuckle
Aluminum housing
Aluminum spill light and
glare light control visor
Diode light source — LED
O`= TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States.
02015, 2019 Musco Sports Lighting, LLC • U.S. and foreign patent(s) issued and pending. • M-2219-en04-3
musco
Luminaire and Driver - TLC-LED-550
Luminaire Data
Weight (luminaire)
25 lb (11 kg)
UL listing number
E338094
UL listed for USA/Canada
UL1598 CSA-C22.2 No.250.0
CE Declaration
LVD, EMC, RoHS
Ingress protection (luminaire)
IP65
Impact rating
IK07
Material and finish
Aluminum, powder -coat
painted
Wind speed rating (aiming only)
150 mi/h (67 m/s)
UL, IEC ambient temperature rating
(luminaire)
Photometric Characteristics
Projected lumen maintenance per IESTM-21-11
50°C (1220F)
L90 (20k)
>120,000 h
L80 (20k)
>120,000 h
L70 (20k)
>120,000 h
Lumens'
67,000
CIE correlated color temperature
5700 K
Color rendering index (CRI)
75 typ, 70 min
LED binning tolerance
7-step MacAdam Ellipse
Footnotes:
1) Incorporates appropriate dirt depreciation factor for life of luminaire.
All components from foundation to poletop are designed to work
together in Light -Structure System" to ensure reliable, trouble -free
operation.
U.S. and foreign patent(s) issued and pending • 2018, 2021 Musco Sports Lighting, LLC • TLC-LED-550 570OK 75 CRI • M-4740-en04-1
1
Luminaire and Driver - TLC-LED-550
Driver Data
Typical Wiring
Electrical Data
Rated wattage'
Per driver
1080 W
Surges
Per luminaire
540 W
protection
Number of luminaires per driver
2
o
;Controller ; Luminaire
Starting (inrush) current
<40 A, 256 µs
(if present)
L1 Disconnect Fuse ---------
Fuse rating
15 A
Driver
_
UL, IEC ambient temperature rating,
50*C 022°F)
L2* Fuse
electrical components enclosure
Luminaire
Ingress protection, electrical
IP54
components enclosure
* If L2 is neutral then not switched or fused.
Efficiency
95%
t Not present if indoor installation.
Dimming mode
optional
Range, energy consumption
15 - 100%
Range, light output
20 - 100%
Flicker
<2%
Total harmonic distortion (THD) at full
<20%
output
Max operating current per luminaireZ 3.32 A 3.19 A 3.02 A 2.89 A 2.77 A 2.40 A 1.92 A 1.75 A 1.66 A 1.60 A
'
Footnotes:
1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment.
2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances.
Notes
1. Use thermal magnetic HID -rated or D-curve circuit breakers.
2. See Musco Control System Summary for circuit information.
15.00 in
(381 mm)
23.75 in
(603 mm)
T_
po
12.00 in
305 mm)
22.50 in
(572 mm)
1.39 A
CX= U.S. and foreign patents) issued and pending • 2018, 2021 Musco Sports Lighting, LLC • TLC-LED-550 5700K 75 CRI • M-4740-en04-1
musco
lA
Overview
Control -Link° Control and Monitoring System provides remote
on/off control, dimming, system monitoring, and management
of your lighting system.
Features
Control
• Lighting system and auxiliary equipment
• Control with: Control -Link website, smartphone app,
phone call, email, or fax up to 10 years in advance
• Seven controllable lighting zones
• Three customizable dimming levels (factory set at
100%,50%,20%)
• Multi -level user security settings
• Door -mounted or remote -mounted on/off/auto switches
allow for manual override of automated control
Monitoring
• Detects luminaire outages and other issues that affect light
quality
Management and Support
• Control -Link Central"" service center provides
support 24 hours a day, 7 days a week for scheduling,
monitoring, and reporting
• Luminaire outage notification within the next business day
• Customized usage reports through website
OC= ©2019, 2021 Musco Sports Lighting, LLC - Control -Link, is a registered trademark of Musco Corporation in the United States.
U.S. patents issued and pending. M-3089-en04-2
musco
Technical Specifications
Control and Monitoring Cabinet Ratings
UL 508A Listed ....................................... E204954
CE declaration................................LVD, EMC, RoHS
IEC 60439-1 compliant .............. UL test report 05NK26317
IEC Emissions/Immunity .....................Class A compliant
Operating temperature .......... -4°F to 140°F (-20°C to 60°C)
FCC Part 15 .................................Class A compliant
Weight for 72 inch (1829 mm) cabinet ...........180 lb (82 kg)
24.00 in
(610 mm)
18.00 in
0.44 in dia. (457 mm)
(11 mm)
n
Weight for 48 inch (1219 mm) cabinet ........... 140 lb (64 kg)
Short Circuit Current Rating (SCCR) 72.00 in
with 30 A contactors 18 kA (1829 mm)
with 60 or 100 A contactors 25 kA 731 in
*Minimum circuit breaker interrupt rating must be greater than or equal
to SCCR rating listed above. 49.25 in
(1251 mm)
Construction 48.00 in
(1219 mm)
Control and Monitoring Cabinet
• NEMA type 4 (IP65) cabinet
• Powder -coated aluminum 5052 H32 cabinet and panel
• Lockable, 3-point latch
• Supports lighting system voltage up to 480 V
• Requires 120 V or 230 V phase -to -neutral control voltage
• Protective cover isolates high voltage
On/Off/Auto Manual Switches Cabinet (optional)
• NEMA type 4 (IP65) cabinet
• Powder -coated aluminum 5052 H32 cabinet and panel
• Lockable door
• Hinged interior panel for switch mounting
Remote Wireless Antenna Cabinet (for wireless
communication)
• Cast aluminum with texture gray paint finish
• Omnidirectional antenna
• Operating temperature: -40°C (-40°F) to 85°C to (185°F)
• Frequency: 900 MHz or 2.4 GHz
_ 12.86 in
(327 mm)
11.38 in
(289 mm)
10.00 in
r (254 mm)
n
15.75 in
(400 mm)
0.44 in dia.
(11 mm)
12.00 in
(305 mm)�
11.69 in
(297 mr,
17.00 in
(432mm)
1
0
(400 00 mm)
Manual switches cabinet
i t� D
7.8 in
(200 man
4.5 in
(115 mm)
Remote wireless antenna cabinet
VccO ©2019, 2021 Musco Sports Lighting, LLC - Control -Link® is a registered trademark of Musco Corporation in the United States.
U.S. patents issued and pending. M-3089-en04-2
musco,
N
Internal Details
• Factory wired, programmed, and tested
• Internallyfused
• Control power terminal blocks provided
• One control circuit operates entire cabinet
• Plug-in wire harnesses provided to connect multiple cabinets
Control Module
Receives and stores schedules from Control -Link Central —
service center, operates your equipment, and verifies
schedules were carried out.
• Executes scheduled on/off or dimming events.
• Stores schedules for up to 7 days
• Reboots automatically and executes current schedule
when power is restored, in case of power interruption
• Monitors Musco lighting system and reports issues
to keep facilities operating and to help plan routine
maintenance. Alerts Control -Link Central service center to
schedule appropriate action or maintenance.
Communication Modules
Communication with Control -Link Central is done via an
integrated, high speed, cellular connection with no additional
monthly charges during the warranty period.
Communication with light poles is done via powerline
communication or wireless communication.
• Powerline communication requires a dedicated 20A circuit
(lighting circuit distribution panel)
• Wireless communication requires a dedicated antenna to
be mounted at least 3 ft above the cellular antenna, and
7 ft total distance away, and line of sight to lighting poles.
Contactor Modules
Operates equipment based on control module schedules.
• Compliant with IEC 60947-4-1 for continuous operation at
100% of rated current
• Contactors rated for 30, 60, or 100 amps
Ground Bar
Provides integral ground bar for lighting equipment grounding.
HTHHTH
d
------------------------------------------
`..
CAI=1E G:i�
oil
o 0
■ o o ■
���
��■
C�I�I�e1
0 0
—N
is
�
CAI=1��
FRI
l_I
l Iti
o 0
OO OO
o 0
,q
/`/ `JO ©2019, 2021 Musco Sports Lighting, LLC - Control -Link. is a registered trademark of Musco Corporation in the United States.
U.S. patents issued and pending. M-3089-en04-2
musco
L
C
rMot alelfftno @7 Wra 7Mo o 04 2Z
z F
N
COPYRIGHT (C) MUSOO UGHTING INC. 2005
Not to be reproduced in whole or put without
the wdtten ocneent of Mueoo Ughting Inc.
6-32 Thrd.
5.38
P&A
0
0
0
O
0
0
0
27
2.81
0
Pushbutton
Switch
Strobe
Contractor Wiring
2 wires for the pushbutton (12 AWG)
2 wires for the strobe light (12 AWG)
Controller
Pushbutton
Dimensions in inches
Color: Black bezel and gray housing.
Silver actuator
Material: Machined SS actuator.
Machined AL bezel
Malleable iron housing
Contact Current Rating: 15A (125VAC)
Internal Ground Screw
Torx Cover Screws (T-10)
W
SEQUENCE OF OPERATION (Control —Link):
1. The OOA needs to be in the AUTO position. A
schedule begins and the REC closes the 1/0 relay
which sends control power to the pushbutton.
2. The pushbutton is pressed to turn on the lights. The
contactors pull in, which also activates the holding
circuit. The lights remain ON for the preset amount
of time dictated by the timer dial T1 (Bottom Dial).
3. The timer times out and performs 2 functions.
3.1. Power from the timer is sent to the strobe as a
warning that the lights will extinguish in Y
amount of time (dictated by dial T2 (Top Dial)),
3.2. The timer activates a count down for the circuit
to turn off.
4. If the pushbutton is pressed again, before the strobe
turns off, the lights will remain ON for another cycle.
5. If the pushbutton is NOT pressed again the strobe
and lights will extinguish.
Strobe Light
Dimensions in inches
Color: Amber
Flash Rate/Minute: 90
Candlepower Peak: 1,000,000
Effective Candlepower: 300
MEYERS HUB, 1/2"NPT
NIPPLE, 1/2"NPT CLOSE
TIMER SETTINGS:
—Mode: A
—T2 (Time setting for Strobe Light)
—Range: 1 M (6 sec to 6 min)
—Turn dial to 5 (5 min)
—T1 (Playing Time)
—Range: 1 H (6 min to 6 hr)
Turn dial to 1 (1 Hr)
Strobe
0000
RANGE
T2 e
MW e
RANGE
T1 e
�00
00
W 'D C4
U
rZ
W a004
0G0
C O` ON
O m� 000
ao\
a
p O Y O
c0i 10
a:o o ago
J0B NUMBER:
DRAWN BY:
P. Hector
CHECK BY:
REPRESENTATIVE:
SCALE:
NS
DATE.
s/1/os
DRAWING NUMBER:
OF SHEETS
UL Product Certification for:
Musco Sports Lighting, LLC
100 1 st Ave W
PO Box 808
Oskaloosa, IA 52577
USA
High -Intensity Discharge Green Generation"" luminaires and remote ballast assemblies
Surface -Mounted Luminaires SportsCluster® and SportsCluster-2® luminaires and
ballast assemblies
• Light -Structure 2- and Light -Structure System"" luminaires any
remote ballast assemblies
• 1000 W Light -Palo"' and Light -Pak indoor luminaires
with Multi -Watt"" control system
• 1000 W Show -Light"" and Show -Light Green"' luminaires with
hooded light actuator system and remote ballast assemblies
• 2000 W Mirtran luminaire
• Stadium 2K Fixtures"" 2000 W luminaire and
Hot Restrike Green' 2000 W hot restrike luminaire
I
Management Equipment, Energy
Industrial Control Panels
Emergency Lighting and
Power Equipment
Lighting control systems for:
• Control -Link® control and
monitoring system
• Control -Link retrofit control system
Control panels and enclosures for: FF
• Control -Link® control and
monitoring system
• Control -Link retrofit control system
• Lighting contactor cabinets
Multi -Watt" control systems
• Auxiliary Lighting Interface Cabinet
(ALIC)
remote
E33316
E 139944
E204954
E311491
Luminaire Fittings Galvanized steel poles 12 ft (3.7 m) or less for: E132445
• Poles for Mirtran luminaire mounting
Rooftop poles
• Special applications
=Md
Luminaire Pole in Excess of Galvanized steel poles greater than 12 ft (3.7 m) for: E325078
12 ft (3.7 m) Light -Structure System"' luminaire mounting
• Sportspole- structure or mounting system and special applications
®RAskA•
11 �
02011, 2017 Musco Sports Lighting, LLC • M-1684-en04-10
Devices, Scaffolding Service platforms for: SA7004
• Light -Structure System"" luminaires and remote ballast assemblies
• SportsCluster® System luminaires and remote ballast assemblies
Lightning Conductors, Air Terminals, Light -Structure System"' pole structure concrete base E337467
and Fittings
Light -Emitting -Diode LED luminaires and driver assemblies E338094
Surface -Mounted Luminaires LED auxiliary luminaires
A copy of the UL Certificate of Compliance is available upon your request.
�NO�T�T�
11 �
©2011, 2017 Musco Sports Lighting, LLC - M-1684-en04-10
Manufacturer's Certification of Corrosion Protection for
Light -Structure System" and SportsCluster' Lighting Systems
The following standard corrosion protection is provided on your equipment:
• All exposed components are constructed of corrosion -resistant material and/or coated to protect against corrosion.
• All exposed carbon steel is hot -dip galvanized, meeting ASTM A123 and ISO/EN 1461.
• All exposed aluminum is powder -coated with high-performance polyester or anodized. All exterior reflective inserts are
anodized, coated with a clear, high -gloss, durable fluorocarbon, and protected from direct environmental exposure to
prevent reflective degradation or corrosion.
• All exposed hardware and fasteners are stainless steel, passivated, and coated with an aluminum based thermosetting ep-
oxy resin for protection against corrosion and stress corrosion cracking. Alternately, for hardware in non -stressed applica-
tions, an electroless nickel coating meeting ASTM B733 may be used. Pole strapping used to mount certain equipment to
light poles is annealed grade 304 stainless steel and passivated.
• Certain structural fasteners are carbon steel, galvanized meeting ASTM A153 and ISO/EN 1461 (for hot -dip galvanizing), or
ASTM B695 (for mechanical galvanizing).
This corrosion protection package only applies to equipment manufactured by Musco.
Musco Sports Lighting, LLC
rem
/
Greg Kubbe
Director of Product Performance
•T•T•T•
•
2005, 2020 Musco Sports Lighting, LLC - M-1502-en04-6
Date: March 18, 2024 Project Name: Wilson Park Pickleball Project #: 227370
1. SELLER NAME AND ADDRESS:
2. BUYER NAME AND ADDRESS:
Musco Sports Lighting, LLC ("Musco")
City of Fayetteville (the "Buyer")
100 1 s' Avenue West — PO Box 808
113 West Mountain Street
Oskaloosa, IA 52577
Fayetteville, AR 72701
Attn: Jeff Annen
Attn: Lioneld Jordan
Email: jeff.annen@musco.com
Email: mayor@fayetteville-ar.gov
Telephone: 641-673-0411
Telephone: 479-521-7700
800-825-6020 Ext 4081
3. OWNER NAME AND ADDRESS:
4. SHIPPING NAME AND ADDRESS:
City of Fayetteville
Wilson Park
113 West Mountain Street
675 North Park Avenue
Fayetteville, AR 72701
Fayetteville, AR 72701
Attn: Lee Farmer
Attn: Tim Edwards
Email. (farmer@fayetteville-ar.gov
Email: tim@ckingelectric.net
Telephone: 479-444-3481
Telephone: 479-957-2490
5. WARRANTY CONTACT:
6. FACILITY NAME AND ADDRESS:
City of Fayetteville (the "Buyer")
Wilson Park
113 West Mountain Street
675 North Park Avenue
Fayetteville, AR 72701
Fayetteville, AR 72701
Attn: Lee Farmer
Email: Ifarmer@fayetteville-ar.gov
Telephone: 479-444-3481
7. EQUIPMENT DESCRIPTION — Musco shall sell, transfer, and deliver to Buyer, and Buyer will purchase,
accept, and pay for the following goods (the "Equipment") in accordance with the "Total Price" paragraph
of this Agreement:
Light -Structure SystemTM Foundation-to-Poletop Lighting System
• 18 — Total Light ControlTm TLC-LED-550 factory -aimed and assembled luminaires
• Pole length factory assembled wire harnesses
• Factory wired and tested remote electrical component enclosures
• 2 - 30 ft galvanized steel poles
• 4 - 40 ft galvanized steel poles
• 6 Pre -cast concrete bases with integrated lightning grounding
With Controls
• Player -activated pushbutton control system with strobe to provide timed on/off control
• Control-Linke control and monitoring system to provide remote on/off and dimming
(high/medium/low) control and performance monitoring with 24/7 customer support
Built to the following specifications:
• Driver input voltage: 240
• Phase to pole: 1 phase
• Structural integrity: based upon IBC, 2021, 110mph, Exposure C
• Light level(s): 30 footcandles
8. RESPONSIBILITIES OF THE BUYER AND/OR THIRD PARTY — buyer/Third Party agrees to:
• Confirm supply voltage required for lighting system.
• Confirm pole or luminaire locations.
• Provide electrical design and materials for electrical distribution system.
• Provide labor and equipment for installation of electrical distribution system.
• Provide labor and equipment for installation of bases & poles.
1999, 2023 Musco Sports Lighting, LLC • M-1010-enUS116
Page 1 of 5
Date: March 18, 2024 Project Name: Wilson Park Pickleball Project #: 227370
9. MUSCO CONTROL -LINK° CONTROL SYSTEM — Musco agrees to provide design and layout for the
control system. In addition to the Equipment, Musco agrees to provide the following:
Control -Link CentralTM customer support services: commission the system; monitor and report system
alarms; provide automated facility management reports; provide on -off schedules via Control -Link
Central TM app or website, email,or phone call, and provide technical support 24 hours a day, seven days
a week.
10. MUSCO SERVICES — Musco agrees to provide, itself or through its subcontractors, design, layout, testing
and commissioning for the Equipment and the following (collectively, the "Services"):
No additional Services
11. CONSTANT 25TM WARRANTY & MAINTENANCE PROGRAM (the "Warranty") — Musco shall provide
parts, labor, and services as outlined in the Musco Constant 25 Warranty Agreement to maintain operation
of lighting equipment for a period of 25 years on the following terms:
• Warranty service begins: On the date of product shipment
• Expiration date: 25 years from date of shipment
• Monitoring, maintenance & control services
• Light levels — as specified in Musco design documents
• Spill light control — as specified in Musco design documents
• Energy consumption: as specified in Musco design documents
12. TOTAL PRICE — Buyer will pay for the above -described Equipment and, if applicable, Services. The Total
Price of $86,607.00 plus applicable taxes is payable as follows.
• $86,607.00 within 30 days from invoice date
A copy of the payment and performance bond (if applicable) is required prior to shipment.
Monthly progress invoicing and payments will apply.
Final payment shall not be withheld by Buyer on account of delays beyond the control of Musco.
Project is being purchased through the following cooperative purchasing agreement:
Sourcewell (contract number 041123-MSL)
Price includes delivery, to the address indicated in item #4 of this Agreement. Price does not include sales
tax, unloading or installation.
Source of Funds: Buyer agrees that Buyer's payment to Musco is not contingent upon Buyer getting
paid by the Owner/End User.
Buyer may not hold back or set off any amounts owed to Musco in satisfaction of any claims asserted by
Buyer against Musco. No partial payment by Buyer shall constitute satisfaction of the entire outstanding
balance of any invoice of Musco, notwithstanding any notation or statement accompanying that payment.
The Total Price was calculated utilizing parameters outlined in the project specifications. In the event soil
conditions vary from those relied upon, or if the soil cannot be readily excavated, Buyer shall be
responsible for Musco's additional associated costs, including but not limited to the cost of design,
alternate foundations, additional materials, and labor.
13. TAXES — Buyer shall pay all applicable state and local sales taxes, use or any similar tax invoiced
appropriately by Musco.
® Taxable ❑ Non -Taxable (Copy of resale or exemption certificate must be attached. Note:
Just holding a sales tax permit does not, in and of itself, qualify for
a non-taxable sale.)
0000
Musco
1999. 2023 Musco Sports Lighting, LLC • M-1010-enUS-46
Page 2 of 5
Date: March 18, 2024 Project Name: Wilson Park Pickleball Project #: 227370
14. PAYMENT/PERFORMANCE BONDING — Is there a bond on this project? ❑ Yes ® No
Principal Bond Holder:
Bonding Company Name:
Bonding Company Address:
Bonding Company Address
Phone Number:
Bond Number:
15. DELIVERY — Normal delivery to the shipping address indicated above is 10 to 12 weeks after submittal
approval or release of order, if later. If the Equipment is shipped in multiple lots, Musco shall prepare a
separate invoice for the price of the Equipment shipped at the time of each shipment. Buyer shall pay the
amount of each such invoice upon the same terms as set out in the "Total Price" paragraph of this
Agreement.
All deliveries shall be made by means of a common carrier or some other reasonable means chosen by
Musco. All risk of loss to Equipment sold shall pass to Buyer upon delivery by Musco of such Equipment
to the shipping location indicated above.
Delivery is subject to Buyer maintaining credit satisfactory to Musco. Musco may suspend or delay
performance or delivery at any time pending receipt of assurances, including full or partial prepayment or
payment of any outstanding amounts owed adequate to Musco in its discretion, of Buyer's ability to pay.
Failure to provide such assurances shall entitle Musco to cancel this contract without further liability or
obligation to Buyer.
16. NO RETAINAGE/WARRANTY — Buyer acknowledges payment in full is required within the agreed terms.
Warranty claims and back charges shall not be deducted from contract payments without prior approval
of Musco's Warranty Department (877-347-3319). Musco's Equipment and its performance are sold
subject to Musco's written warranty. The Warranty provided by Musco shall be in lieu of all other
representations, warranties and conditions of any kind, in respect of the Equipment or the Services and
Musco disclaims any other representation, warranty or condition whatsoever, whether written or oral,
express or implied, statutory or otherwise, including, but not limited to, the implied warranties and
conditions of merchantability and fitness for a particular purpose.
Buyer acknowledges that any warranty and/or maintenance guarantee contained within
payment/performance bonds issued on Musco's behalf pursuant to this Agreement and the corresponding
liability on behalf of the issuing surety shall apply only to the first 12 months of any warranty and/or
maintenance obligation of Musco specified in the written Warranty to be delivered to Buyer. The balance
of any warranty and/or maintenance obligation greater than 12 months shall be the sole responsibility of
Musco and shall not be guaranteed by a third party.
17. EXCLUSION OF SPECIAL DAMAGES — In no event shall Musco be liable for incidental, special or
consequential damages, including without limitation lost revenues and profits, in respect of this Agreement
or the Equipment and, if applicable, Services provided hereunder.
18. LIMITATIONS PERIOD — Unless otherwise specified in the Warranty to be delivered to Buyer, any action
or proceeding against Musco arising out of or relating to the Equipment or Services will be forever barred
unless commenced within the earlier 4 (a) one (1) year after delivery of the Equipment or if applicable
the period prescribed by the applicable statute of limitation or repose.
musco
1999, 2023 Musco Sports Lighting, LLC • M-1010-enUS-46
Page 3 of 5
Date: March 18, 2024 Project Name: Wilson Park Pickleball Project #: 227370
19. SECURITY AGREEMENT IR GGRs deratiGR ef the pFem sets GentaiRed heFeiR, Buyer heFeby gicants and
appliGable, land titles eF Feal pl:eperty regi6tFieG) aRY initial finanGiRg statements, financing Ghange
statements, nGtiGes of seGUFity intere6t Or other dGGUrrients relating te this seGYFity iRterest eF this
traRGaGtiGR. Buyer fuFther agrees te promptly furnish ally infoFlTlatiOR n ester! by M s o to effect'ote
the terms ofthits Agreement. Buyer further agrees te exeGute any deGUrnent reasonably required by MUGGe
GUGh seGLIFity interest. Buyer agrees that value has beeR giveR fel: this 6eG6lFitY inteFest and that the parties
have net agreed to nnstnene the time for ettnshment of the s rr'ty interest
20. INSURANCE — From and after delivery, regardless of the pending performance of the Services, until such
time as Buyer has performed in full all obligations contained herein, Buyer shall maintain adequate
insurance covering the Equipment in accordance with generally accepted business practices. Buyer shall
name Musco as loss payee until such time as Buyer has performed in full all obligations contained herein.
21. DEFAULT — Each of the following shall constitute a default ("Default") under this Agreement: a) failure to
pay, in full, any payment when due hereunder; b) Buyer becomes the subject of a bankruptcy, receivership
or insolvency proceeding; c) any warranty, representation or statement made or furnished to Musco by or
on behalf of the Buyer proved to have been false in any material respect when made or furnished, d) loss,
theft, damage, destruction or encumbrance to, or of, the Secured Property or the making of any levee,
seizure or attachment thereof or thereon prior to payment in full, or e) the occurrence or non-occurrence
of any event or events which causes Musco, in good faith, to deem itself insecure for any reason
whatsoever.
22. REMEDIES UPON DEFAULT — In the event of Default, Musco may, at its option, and without notice or
demand: a) declare the entire unpaid balance owing hereunder due and payable at once; b) proceed to
recover judgment for the entire unpaid balance due, c) exercise all rights provided to Musco under this
Agreement, any applicable personal property security act (or similar legislation), at law or in equity
including but not limited to entering the Buyer's premises and taking possession of the Secured Property.
All the remedies described herein are cumulative and may be exercised in any order by Musco. Buyer
agrees to pay all costs (including reasonable attorney's fees and court costs) incurred by Musco in
disposing of the Secured Property and collecting any amounts owing hereunder, and such costs shall be
part of the obligations secured hereunder.
23. FORCE MAJEURE — Musco shall not be liable for delays or failure to perform in respect of the Equipment
or the Services due, directly or indirectly, to (i) causes beyond Musco's reasonable control, or (ii) acts of
God or nature, acts (including failure to act) of any governmental authority, wars (declared or undeclared),
strikes or other labor disputes, fires, and natural calamities (such as floods, earthquakes, storms,
epidemics).
24. EEO COMPLIANCE — When applicable, Musco and Subcontractor shall comply with the EEO
Clause in Section 202 of Executive Order 11246, as amended, which is incorporated herein by
specific reference.
When applicable, Musco and Subcontractor shall abide by the requirements of 41 CFR 60-741.5(a)
and 41 CFR 60-300.5(a). These regulations prohibit discrimination against qualified individuals
on the basis of disability and against qualified protected veterans, and require affirmative action
by covered prime contractors and subcontractors to employ and advance in employment
qualified individuals with disabilities and qualified protected veterans.
25. CONDITIONS OF AGREEMENT
a. APPLICABLE LAW — This Agreement shall be governed by the laws, including the Uniform
Commercial Code, adopted in the State of Arkansas as effective and in force on the date of this
Agreement.
0000
musco
1999. 2023 Musco Sports Lighting, LLC • M-1010-enUS-46
Page 4 of 5
Date: March 18, 2024 Project Name: Wilson Park Pickleball Project #: 227370
b. EXPENSES/REMEDIES — Buyer shall pay to Musco the reasonable expenses, including court costs,
legal and administrative expenses, and reasonable legal fees (on a solicitor and client basis), paid
or incurred by Musco in endeavoring to collect amounts due from Buyer to Musco. It is further
understood that if Buyer does not make a payment as due, Musco has the right to forward appropriate
notices or claims on jobs with owners, bonding companies, general contractors, or the like, as
deemed appropriate by Musco.
c. ENTIRE AGREEMENT — This Agreement, the written Warranty to be delivered to Buyer, and any
invoice issued by Musco pursuant to this Agreement constitute the entire agreement between the
parties and supersede all prior statements of any kind made by the parties or their representatives.
No representative or employee of Musco has any authority to bind Musco to any term, representation,
or warranty other than those specifically included in this written Agreement or the written Warranty
to be delivered to Buyer in connection with this Agreement. This Agreement may not be amended or
supplemented except by written agreement executed by Musco and Buyer.
d. ACCEPTANCE — This Agreement is subject to the approval of Musco's Credit Department and the
written acceptance of this Order by Musco.
e. Buyer's acceptance of this Agreement is limited to acceptance of the express terms of this
Agreement and does not include any additional or different terms proposed by the Buyer or any
attempt to Buyer to vary the terms and conditions herein contained are expressly rejected and shall
be void and of no effect.
CITY OF FAYETTEVILLE MUSCO SPORTS LIGHTING, LLC
Acceptance Acceptance
this day of 20 this 19th day of March , 2024
r
ignature Signs
Lioneld Jord ayor James M. Hansen. Secretary
Name and Title Name and Title
Please remember to return all pages of this agreement.
i I (' ) 1999, 2023 Musco Sports Lighting, LLC • M-1010-enUS-46
muSCo • • ..
Page 5 of 5