HomeMy WebLinkAbout2024-02-27 - Agendas - Final
City Council Transportation Committee
Tuesday, February 27,2024
5:30 pm or Immediately Following the City Council Agenda Session
City Hall Room 111
VIDEO CONFERENCING BY ZOOM WILL BE AVAILABLE FOR THIS MEETING. TO
REGISTER FOR THE MEETING GO TO THIS REGISTRATION LINK
https://us06web.zoom.us/webinar/register/WN_cPGBon8cS7m96aqjLsB0bA
Members: Sarah Bunch, Holly Hertzberg; Sarah Moore, Bob Stafford
City Staff: Chris Brown, Public Works Director/City Engineer; Terry Gulley, Asst. PW Director
for Operations/Transportation Services Director
Agenda:
1. New Business:
A. DICKSON STREET IMPROVEMENTS: Update on the improvements planned for
2024 along Dickson Street.
2. Reports and Presentations:
A. Transit Discussion
3. Informational Items (These Projects are all on City Council Consent Agenda):
A. Benchmark Construction Company of NWA, Inc. construction contract for
North and College Intersection Project.
4. Adjourn
LP
LP
LP
P
LP
U
G
T
S
UGTSUGTS
UGTS
LP
LP
EX
.
R
/
W
EX
.
R
/
W
EX
.
R
/
W
EX
.
R
/
W
EX
.
R
/
W
EX
.
R
/
W
EX.R/W
EX.R/W
EX
.
R
/
W
EX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/W
EX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/W
EX
.
R
/
W
EX
.
R
/
W
EX
.
R
/
W
EX.R/W EX.R/W EX.R/W EX.R/W
EX.R/W
EX.R/W
EX
.
R
/
W
LP
WS
WS
WS
W-12 W-12 W-12 W-12
W-12 W-12
W-12 W-12 W-12 W-12 W-12
W-12 W-12 W-12 W-12
W-12 W-12 W-12 W-12 W-12 W-12
W-
2
W-
2
W-
2
W-
2
W-
2
W-
2
W-
2
S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8
S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8
S-
1
2
S-
1
2
S-
1
2
S-
1
2
S-
1
2
S-
1
2
S-
1
2
S-
1
2
S-
1
2
1
3
3
5
1
3
3
2
1332
1
3
3
3
1333
1
3
3
4
1
3
3
6
13
3
1
EX.R/W EX.R/W EX.R/W EX.R/W EX.R/W EX.R/W EX.R/W
EX
.
R
/
W
EX
.
R
/
W
EX
.
R
/
W
LP
STRUCTURE - (47)
STRUCTURE - (48)
8" PVC @ -1.75%
8" PVC @ -3.45%
0+
0
0
1+
0
0
2+00
18" RCP @ 0.
5
1
%
1331.55
1331.23
1331.18 P ELEC.CONDUIT
ELEC.CONDUIT
ELEC.CONDUIT
ELEC.CONDUIT
ELEC.CONDUIT
ELEC.
C
O
N
D
U
I
T
ELEC.CONDUIT ELEC.CONDUIT ELEC.C
O
N
D
U
I
T
Install 65.80 L.F. of 18" RCP @ 0.51%55.79 L.F. of 24" RCP @ 0.85%
N-1
RIM:1333.87
STA. 1+86.3 L
INV OUT:1326.40 W
M-2
RIM:1332.37
STA. 1+08.3 L
INV IN:1326.04" E
INV OUT:1326.04 W
M-1
RIM:1331.71
STA. 0+40.4 L
INV IN:1325.53" E
-0+20 0+00
13
3
2
.
9
5
13
3
2
.
9
5
0+20
13
3
2
.
5
5
13
3
2
.
5
5
0+40
13
3
2
.
1
5
13
3
2
.
1
5
0+60
13
3
1
.
8
9
13
3
1
.
8
9
0+80
13
3
1
.
7
2
13
3
1
.
7
2
1+00
13
3
1
.
7
4
13
3
1
.
7
4
1+20
13
3
1
.
6
2
13
3
1
.
6
2
1+40
13
3
1
.
4
5
13
3
1
.
4
5
1+60
13
3
1
.
3
6
13
3
1
.
3
6
1+80
13
3
1
.
6
5
13
3
1
.
6
5
2+00
13
3
1
.
8
8
13
3
1
.
8
8
2+20
13
3
2
.
4
9
13
3
2
.
4
9
2+40
13
3
2
.
8
5
13
3
2
.
8
5
2+60
13
3
3
.
2
9
13
3
3
.
2
9
2+80
13
3
3
.
7
0
13
3
3
.
7
0
3+00
13
3
4
.
0
9
13
3
4
.
0
9
3+20
13
3
4
.
4
8
13
3
4
.
4
8
3+40
13
3
5
.
1
2
13
3
5
.
1
2
3+60
13
3
5
.
7
7
13
3
5
.
7
7
3+80
13
3
6
.
5
1
13
3
6
.
5
1
Scale: 1" = 30'
30 0 30
PP-1
OV
E
R
A
L
L
P
L
A
N
&
DI
C
K
S
O
N
/
S
C
H
O
O
L
B
U
M
P
O
U
T
P
L
A
N
MC
CW
K:
\
E
n
g
i
n
e
e
r
i
n
g
D
e
s
i
g
n
S
e
r
v
i
c
e
s
\
P
r
o
j
e
c
t
s
\
B
O
N
D
P
R
O
G
R
A
M
\
2
0
1
9
B
o
n
d
P
r
o
g
r
a
m
\
D
o
w
n
t
o
w
n
W
a
l
k
a
b
i
l
i
t
y
\
D
i
c
k
s
o
n
S
t
r
e
e
t
\
D
W
G
\
D
i
c
k
s
o
n
S
t
r
e
e
t
P
r
o
p
o
s
e
d
B
a
s
e
M
a
p
-
C
W
.
d
w
g
Mar 28, 2023
DI
C
K
S
O
N
S
T
R
E
E
T
WA
L
K
A
B
I
L
I
T
Y
I
M
P
R
O
V
E
M
E
N
T
S
DD
CI
T
Y
O
F
AR
K
A
N
S
A
S
FA
Y
E
T
T
E
V
I
L
L
E
EXISTING CENTERLINE
PROPOSED CENTERLINE
1310
1315
1320
1325
EX
.
G
R
A
D
E
FI
N
I
S
H
E
D
GR
A
D
E
1330
1335
1340
1345
SCALE: 30H : 10V
R19.5'
F & I THERMO
WHITE LEFT TURN
ARROW
F & I THERMO
WHITE STRAIGHT
OR RIGHT TURN
ARROW
F & I THERMO
WHITE ONLY
MARKINGS
F & I 6" PAINTED
DOUBLE YELLOW
CENTERLINE STRIPE
F & I TRUNCATED
DOMES FOR ADA
RAMPS
11'
11'
11'
22'22'
73.33'
11.78'
F & I 18" THERMO
WHITE STOP LINE
3' CURB TAPER
3' CURB TAPER
F & I DROP INLET
EXTENSION
MODIFY STRUCTURE
M-2 BY CONVERTING
4' X 4' STORM BOX
INTO 4' X 8' STORM
BOX
MATCH EXISTING
CONCRETE
MATCH EXISTING
CONCRETE
MATCH EXISTING
CONCRETE
DICKSON ST.
WE
S
T
A
V
E
.
11'
11.93'
RELOCATE LIGHT
POLE 18" BEHIND
NEW CURB TO
EDGE OF BASE
(TYP.) AND
INSTALL NEW 12"
X 12" PULL BOX
RELOCATE LIGHT
POLE 18" BEHIND
NEW CURB TO
EDGE OF BASE
(TYP.) AND
INSTALL NEW 12"
X 12" PULL BOX
PROPOSED CROWN
PROPOSED CROWN
1.
0
0
%
TY
P
.
F & I 4" PAINTED
WHITE ON-STREET
PARKING LINES
1.
0
0
%
TY
P
.
EXISTING 24" RCP PROPOSED 18" RCP
EXISTING STORM BOX
TO BE MODIFIED EXISTING STORM BOX
TO BE MODIFIED
PROPOSED
STORM BOX
F & I TREE GRATE
AND TREE
F & I TREE GRATE
AND TREE
F & I DROP INLET
STRUCTURE N-1 WITH
4' EXTENSION AND
THROAT EXTENSION
120'120'
F & I 2' X 8' THERMO WHITE
CROSSWALK LINES
F & I 2' X 8' THERMO WHITE
CROSSWALK LINES
RE-INSTALL
PARKING KIOSK
RE-INSTALL
BIKE RACK
MODIFY STRUCTURE M-1 BY CONSTRUCTING
THROAT EXTENSION TO NEW CURB
EXTEND WATER VALVE COVER
TO GROUND SURFACE
NOTE: STATIONING CORRESPONDS TO THE
PROPOSED CENTERLINE ALIGNMENT
24" RCP
PROPOSED 4'
EXTENSION
R2.5'
57.07'
F & I 1.5"
ELECTRICAL
CONDUIT
LP
LP
P
L
P
LP
LP
LP
EX.R/W EX.R/W
EX.R/W
EX.R/W EX.R/W
EX
.
R
/
W
EX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/W
EX
.
R
/
W
EX
.
R
/
W
EX.R/WEX.R/WEX.R/WEX.R/WEX.R/WEX.R/W
EX.R/W
EX.R/W EX.R/W
EX.R/W EX.R/W
EX.R/W EX.R/W
EX.R/W
EX.R/WEX.R/WEX.R/WEX.R/W
EX
.
R
/
W
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS WS
WS
WS
WS
WS
W-
6
W-
6
W-
6
W-12 W-12 W-12 W-12 W-12 W-12 W-12 W-12
W-12 W-12
W-12
W-12 W-12 W-12
W-12 W-12 W-12 W-12 W-12 W-12
W-12
S-
6
S-
6
S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8
S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8 S-8
S-8
S-
8
S-
8
S-
8
1
3
3
5
1
3
4
0
13
4
5
1
3
3
3
1
3
3
4
1
3
3
6
1
3
3
7
1
3
3
8
1
3
3
9
1
3
4
1
13
4
2
13
4
3
1
3
4
4
LP
STRUCTURE - (48)
STRUCTURE - (49)
8" PVC @ -3.45%
2+00
3+00
3+63
18" RCP @ 0.
5
1
%
ELEC.CONDUIT
ELEC.CONDUIT
ELEC.
C
O
N
D
U
I
T
ELEC.CONDUIT ELEC.CONDUIT ELEC.C
O
N
D
U
I
T
Install 65.80 L.F. of 18" RCP @ 0.51%
N-1
RIM:1333.87
STA. 1+86.3 L
INV OUT:1326.40 W
2+60
13
3
3
.
2
9
2+80
13
3
3
.
7
0
13
3
3
.
7
0
3+00
13
3
4
.
0
9
13
3
4
.
0
9
3+20
13
3
4
.
4
8
13
3
4
.
4
8
3+40
13
3
5
.
1
2
13
3
5
.
1
2
3+60
13
3
5
.
7
7
13
3
5
.
7
7
3+80
13
3
6
.
5
1
13
3
6
.
5
1
4+00
13
3
7
.
2
5
13
3
7
.
2
5
4+20
13
3
8
.
0
1
13
3
8
.
0
1
4+40
13
3
8
.
7
9
13
3
8
.
7
9
4+60
13
3
9
.
5
5
13
3
9
.
5
5
4+80
13
4
0
.
2
7
13
4
0
.
2
7
5+00
13
4
1
.
0
5
13
4
1
.
0
5
5+20
13
4
1
.
9
6
13
4
1
.
9
6
5+40
13
4
2
.
9
2
13
4
2
.
9
2
5+60
13
4
3
.
9
3
13
4
3
.
9
3
5+80
13
4
4
.
9
3
13
4
4
.
9
3
6+00
13
4
5
.
9
1
13
4
5
.
9
1
6+20
13
4
6
.
9
4
13
4
6
.
9
4
6+40 6+60 6+80
Scale: 1" = 30'
0 30
PP-2
OV
E
R
A
L
L
P
L
A
N
&
DI
C
K
S
O
N
/
S
C
H
O
O
L
B
U
M
P
O
U
T
P
L
A
N
MC
CW
K:
\
E
n
g
i
n
e
e
r
i
n
g
D
e
s
i
g
n
S
e
r
v
i
c
e
s
\
P
r
o
j
e
c
t
s
\
B
O
N
D
P
R
O
G
R
A
M
\
2
0
1
9
B
o
n
d
P
r
o
g
r
a
m
\
D
o
w
n
t
o
w
n
W
a
l
k
a
b
i
l
i
t
y
\
D
i
c
k
s
o
n
S
t
r
e
e
t
\
D
W
G
\
D
i
c
k
s
o
n
S
t
r
e
e
t
P
r
o
p
o
s
e
d
B
a
s
e
M
a
p
-
C
W
.
d
w
g
Mar 28, 2023
DI
C
K
S
O
N
S
T
R
E
E
T
WA
L
K
A
B
I
L
I
T
Y
I
M
P
R
O
V
E
M
E
N
T
S
DD
CI
T
Y
O
F
AR
K
A
N
S
A
S
FA
Y
E
T
T
E
V
I
L
L
E
EXISTING CENTERLINE
PROPOSED CENTERLINE
1320
1325
1330
1335
EX
.
G
R
A
D
E
FI
N
I
S
H
E
D
GR
A
D
E
1340
1345
1350
1355
SCALE: 30H : 10V
30
F & I 6" PAINTED
DOUBLE YELLOW
CENTERLINE STRIPE
22'22'
MATCH EXISTING
CONCRETE
MATCH EXISTING
CONCRETE
DICKSON ST.11'
11.93'
F & I TRUNCATED
DOMES FOR ADA
RAMPS
11'
R9.5'
F & I PAINTED
WHITE TAPER
STRIPE
SC
H
O
O
L
A
V
E
.
11'
R3.5'11.59'
DICKSON ST.
RELOCATE LIGHT POLE 18"
BEHIND NEW CURB TO EDGE
OF BASE (TYP.) AND INSTALL
NEW 12" X 12" PULL BOX
INSTALL NEW LIGHT POLE 18"
BEHIND NEW CURB TO EDGE
OF BASE (TYP.) AND INSTALL
NEW 12" X 12" PULL BOX
F & I 4" PAINTED
WHITE ON-STREET
PARKING LINES
1.
0
0
%
TY
P
.
1.
0
0
%
TY
P
.
1.
0
0
%
TY
P
.
ADA LANDING
FIRE HYDRANT
LOCATION TBD
RAMP SLOPE
IS 8.33%
F & I DROP INLET
WITH 4' EXTENSION
AND THROAT
EXTENSION
PROPOSED 18" RCP
PROPOSED
STORM BOX
8'8'8'
F & I 2' X 8' THERMO WHITE
CROSSWALK LINES
F & I 2' X 6' THERMO WHITE
CROSSWALK LINES
F & I 2' X 6' THERMO WHITE
CROSSWALK LINES
RE-INSTALL
BIKE RACK AND
TRASH CAN
NOTE: STATIONING CORRESPONDS TO THE
PROPOSED CENTERLINE ALIGNMENT
PROPOSED 4'
EXTENSION
R2.5'
F & I 1.5" ELECTRICAL
CONDUIT
F & I 1.5" ELECTRICAL
CONDUIT